1. Introduction
The Yieryi YY-400 is a versatile 4-in-1 water quality tester designed to measure pH, Oxidation-Reduction Potential (ORP), Hydrogen (H2) concentration, and Temperature. This high-accuracy device features a 0.01 pH resolution and automatic temperature compensation, making it suitable for a wide range of applications including drinking water analysis, swimming pools, aquariums, hydroponics, laboratories, and food processing.
This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your YY-400 water quality tester to ensure accurate and reliable measurements.
2. Product Overview
2.1 Device Components

- Protective Cap: Covers the electrode when not in use.
- High Precision Probe: The sensing element for measurements.
- Screen Display: Digital LCD for displaying readings.
- Power Button (ON/OFF): Turns the device on or off.
- HOLD/TEMP Button: Locks the current reading or switches between temperature units.
- MODE/CAL Button: Switches measurement modes (pH, ORP, H2, TEMP) and initiates calibration.
- Battery Compartment: Houses 3*1.5V (LR44) button batteries.
2.2 Screen Display Indicators

- Battery Indicator: Shows remaining battery life.
- Hold Indicator (H): Appears when the reading is locked.
- Measurement Units: µS/cm, mg/L, pH, %, ppm, ppt, ppb, mS/cm, mV, °C, °F, S.G.
- Testing Values: The primary measurement reading.
2.3 Key Functions

- ON/OFF: Power Button.
- HOLD/TEMP: Hold and Temperature shift button.
- MODE/CAL: Mode and Calibration shift button.
- Up/Down Arrows: Adjust values up/down in calibration step.
3. Setup
3.1 Battery Installation

The YY-400 requires 3 x 1.5V (LR44) button batteries. Batteries are not included in the package and must be purchased separately.
- If the low battery indicator flashes, it's time to replace the batteries.
- Open the battery case by unscrewing the top cap.
- Carefully remove the old batteries.
- Insert three new LR44 button batteries, ensuring correct polarity.
- Screw the cap back on securely.
3.2 Electrode Preparation

Before first use, remove the protective cap from the electrode. If the electrode needs replacement:
- Take down the protective cap.
- Gently pull out the old electrode horizontally.
- Insert the new electrode.
- Screw the bolts to secure the new electrode.
4. Operation
4.1 Power On/Off
Press the ON/OFF button to turn the meter on or off.
4.2 Mode Switching
Press the MODE/CAL button to cycle through the measurement modes: pH, ORP/mV, H2 (ppb/ppm), and Temperature.

4.3 pH Calibration
The pH meter features a 3-point calibration process using pH 4.00, pH 6.86, and pH 9.18 buffer solutions. ORP and H2 meters are pre-calibrated.
- Turn on the meter.
- Immerse the instrument into the pH 4.00 buffer solution.
- Press and hold the "MODE/CAL" button for 5 seconds until "CAL" appears on the screen.
- Wait for the reading to stabilize and flash 3 times. This indicates successful 4.00 calibration.
- Rinse the electrode with pure water.
- Immerse the instrument into the pH 6.86 buffer solution.
- Press and hold the "MODE/CAL" button for 5 seconds.
- Wait for the reading to stabilize and flash 3 times. This indicates successful 6.86 calibration.
- Rinse the electrode with pure water.
- Immerse the instrument into the pH 9.18 buffer solution.
- Press and hold the "MODE/CAL" button for 5 seconds.
- Wait for the reading to stabilize and flash 3 times. This indicates successful 9.18 calibration.
- The meter is now calibrated for pH.

4.4 EC/TDS/SALT Calibration
For models with EC/TDS/SALT functions (e.g., EZ-9901, EZ-9902, EZ-9908, EZ-9910, EZ-9909SP, C-600), calibration is performed as follows:

- Turn on the meter.
- Short press the MODE/CAL button to select the desired mode (EC, TDS, or SALT).
- Immerse the electrode into the appropriate standard solution (e.g., 1413 µS/cm for EC).
- Press and hold the MODE/CAL button for 6 seconds.
- Wait for the reading to stabilize and flash 3 times to complete calibration.
- Repeat for other standard solutions if necessary (e.g., 12.88 mS/cm, 111.8 mS/cm).
4.5 Taking Measurements
After calibration, immerse the electrode into the sample solution. Stir gently several times to ensure no air bubbles around the electrode. Wait for the reading to stabilize on the screen.

4.5.1 pH Measurement

The pH range is 0.00-14.00 pH. The meter displays the pH value and temperature simultaneously.
4.5.2 H2 Measurement

The H2 range is 0-2400 ppb or 0.001-2.400 ppm. Note that tap water or regular drinking water typically has 0 hydrogen content. For accurate H2 measurement, the water must be electrolyzed or measured from a hydrogen-rich cup.
4.5.3 ORP Measurement

The ORP range is -999mV to 999mV. ORP measures the negative potential value of water quality.
4.5.4 Temperature Measurement
The temperature range is 0.1-60.0°C (32.0-140°F). The meter automatically compensates for temperature to ensure accurate pH readings. To switch between °C and °F, long press the HOLD/TEMP button.
4.6 Reading Lock Function
Press the HOLD/TEMP key to lock the current reading on the display. Press it again to unlock and resume live measurement.
4.7 Automatic Shut-off
The meter will automatically power off after 5 minutes of inactivity to conserve battery life.
5. Maintenance
5.1 Cleaning the Electrode
After each use, clean the electrode with pure water and keep it dry. This prevents contamination and ensures accurate future readings. For more thorough cleaning, gently wash contacts with a soft brush and mild soap, then rinse thoroughly with water.
5.2 Storage
Always replace the protective cap on the electrode when the meter is not in use. Store the meter in a dry place.
6. Troubleshooting
6.1 pH Reset
- Shut off the meter.
- Press and hold the HOLD/TEMP and MODE/CAL buttons simultaneously. Do not release.
- While holding, press the ON/OFF button.
- Release all buttons. The reset is complete.
6.2 C-600/P-3 pH Reset (if applicable)
Turn on the meter, then press the MODE/CAL button for 10 seconds. The display will show "---", indicating a successful reset.
6.3 Common Issues
- Inaccurate Readings / Calibration Failure: If the meter cannot identify the solution during calibration, or if pH calibration is wrong, please reset the meter and re-calibrate. Ensure the electrode is clean and there are no air bubbles around it during measurement. If issues persist, the electrode may need to be changed.
- H2 Measurement Displays "0": Under normal circumstances, tap water or regular drinking water has zero hydrogen content. To measure H2, use electrolyzed water or water from a hydrogen-rich cup.
- Fluctuating H2 Readings: Hydrogen is volatile. H2 readings will naturally decrease over time as hydrogen escapes the solution.
- Meter Not Working / Damaged: If the product is damaged, cannot be calibrated, or does not work normally upon receipt, please protect the product and contact customer support immediately.
7. Specifications
| Parameter | Range | Resolution | Accuracy |
|---|---|---|---|
| pH | 0.00 - 14.00 pH | 0.01 pH | ±0.05 pH |
| ORP | ±999 mV | 1 mV | ±2 mV |
| H2 | 0 - 2400 ppb; 0.001 - 2.400 ppm | 2 ppb; 2 ppm | ±10 ppb; ±10 ppm |
| Temperature | 0.1 - 60.0°C (32.0 - 140°F) | 1 °C/°F | ±0.5 °C |
7.1 General Specifications
- Operation Environment: 0-60°C (32.0-140°F); RH100%
- Waterproof Level: IP67
- Battery: 3 * 1.5V (LR44) button battery (not included)
- Screen Size: 33 * 24 mm
- Dimensions: 183 * 37 * 37 mm (7.2 * 1.5 * 1.5 in)
- Weight: 90g (3.2 oz)
- Display: LCD digital display with optional backlight
- Automatic Temperature Compensation: 0-60°C
- Automatic Shut-off: 5 minutes
8. User Tips
- Electrode Cleaning: For consistent accuracy, regularly clean the electrode with pure water after each use. Some users find a soft brush and mild soap effective for thorough cleaning of contacts, followed by a good rinse.
- H2 Measurement: Remember that the meter will show '0' for H2 in regular tap water. To get meaningful H2 readings, you need to test electrolyzed water or water from a hydrogen-rich cup.
- Battery Life: Keep spare LR44 batteries on hand, as they are not included with the device and are essential for operation.
- Troubleshooting Fluctuations: If you experience erratic readings, especially for ORP or H2, try performing a pH reset and re-calibration. Ensure the electrode is clean and fully immersed without air bubbles.
9. Warranty and Support
9.1 Warranty
The meter is warranted to be free from defects in material and workmanship for a period of three years from the date of purchase. The warranty covers normal operation but does not cover man-made damage. Proof of purchase is required for warranty repairs. The warranty is void if the meter has been taken apart.
9.2 Return Authorization
Authorization must be obtained from the supplier before returning items for any reason. When requiring a return authorization, please include data regarding the defective reason. The meter is to be returned along with good packing to prevent any damage in shipment and insured against possible damage or loss.
9.3 Additional Resources
A detailed user manual in PDF format is available for download: View User Manual (PDF)
10. Package Contents

- 1 x 4-in-1 Water Quality Tester (YY-400)
- 1 x User Manual
Note: Retail box and batteries are not included.