GEYA GRB8-01/02

Contents

GEYA GRB8-01/02 Twilight Switch User Manual

Automatic Light-Dependent Switching for Street Illumination and Garden Lights

GEYA GRB8-02 Twilight Switch with sensor

Figure 1: GEYA GRB8-02 Twilight Switch with external sensor.

1. Product Overview

The GEYA GRB8-01/02 Twilight Switch is designed for automatic control of lighting systems based on ambient light intensity. It is ideal for applications such as street illumination, garden lights, and advertising displays. The device monitors ambient light via an external sensor and switches the output according to a user-defined light level.

Key Features:

  • Light-dependent switching with external fotosensor.
  • Universal supply voltage: AC 110V-240V.
  • Output: 1 SPST 16A/AC1.
  • GREEN LED for supply indication, RED LED for relay status.
  • Compact 1-MODULE DIN rail mounting.
  • GRB8-02 model includes Zero-Crossing Protection and two light intensity ranges (1-1000Lx & 10-10000Lx).
GEYA GRB8-02 with two light intensity ranges and zero crossing protection

Figure 2: GRB8-02 model highlighting two light intensity ranges and Zero-Crossing Protection.

2. Setup and Installation

2.1 Unpacking

Carefully remove the Twilight Switch and its components from the packaging. Ensure all parts are present and undamaged.

2.2 Mounting

The GEYA GRB8-01/02 Twilight Switch is designed for DIN rail mounting (EN/IEC 60715). Ensure the mounting location is stable and provides adequate ventilation. The device should be installed in a vertical position, and inclination in all directions should not exceed ±22.5°.

2.3 Wiring Diagram

Connect the device according to the appropriate wiring diagram for your model. Ensure all connections are secure and comply with local electrical codes. The maximum cable size for connections is 1x2.5mm² or 2x1.5mm² with a tightening torque of 0.4N.m.

GRB8-01 Wiring Diagram and Function Diagram
Figure 3: GRB8-01 Wiring Diagram, Function Diagram, and Load Types.
GRB8-02 Wiring Diagram and Function Diagram
Figure 4: GRB8-02 Wiring Diagram, Function Diagram, and Load Types.

2.4 Sensor Installation

The external fotosensor (PLS-01) is crucial for the device's operation. It comes with a 20cm cable, which can be extended up to a maximum of 50m using standard wire. The sensor can be fixed by a panel (hole size Ø9.6) or by snap. Ensure the sensor is placed in a location that accurately reflects the ambient light conditions you wish to monitor, away from direct artificial light sources that might interfere with its readings.

Twilight Switch Sensor 20cm
Figure 5: External Twilight Switch Sensor (20cm cable).
Sensor mounting options and example wiring
Figure 6: Sensor mounting options (fixed by panel or snap) and an example wiring diagram.

3. Operating Instructions

3.1 Function Mode Switch

The device features a function mode switch with three positions: ON, AUTO, and OFF.

  • ON: The output is continuously active, regardless of ambient light.
  • AUTO: The device operates based on the ambient light intensity detected by the sensor and the set illumination level.
  • OFF: The output is continuously inactive.

3.2 Illumination Setting (Lx Knob)

The 'Lx' knob allows you to set the desired ambient light intensity level at which the switch will activate or deactivate the load.

  • GRB8-01: Illumination Range 1-100Lx.
  • GRB8-02: Illumination Range 1-1000Lx or 10-10000Lx (selectable via the 'x1/x10' switch).

3.3 Delay Time

Both GRB8-01 and GRB8-02 models have a built-in delay time of approximately 2 minutes. This delay prevents the switch from reacting to momentary changes in light intensity (e.g., car headlights, lightning flashes), ensuring stable operation.

3.4 Load Types and Maximum Wattage

The Twilight Switch is compatible with various lamp types. Ensure the total wattage of connected loads does not exceed the specified maximums:

Lamp Type GRB8-01 Max. Wattage GRB8-02 Max. Wattage
Incandescent3600W2000W
Halogen lamp3600W2000W
Fluorescent, corrected, in series1000W1000W
Fluorescent, corrected, in parallel900W (125µF)900W (125µF)
Compact fluorescent400W400W
LED lamps (<2W)55WN/A
LED lamps (>2W)600W300W

4. Maintenance

The GEYA GRB8-01/02 Twilight Switch is designed for long-term, maintenance-free operation. However, periodic checks and cleaning can help ensure optimal performance.

  • Cleaning: Ensure the device and sensor are free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Connections: Periodically check all electrical connections for tightness and signs of wear or corrosion.
  • Sensor Placement: Verify that the sensor remains unobstructed and in its optimal position for accurate light detection.
  • Safety: Always disconnect power before performing any maintenance or inspection.

5. Troubleshooting

If the Twilight Switch is not functioning as expected, consider the following:

  • Device not switching:
    • Check the function mode switch: Ensure it is set to 'AUTO'.
    • Verify power supply: Check if the GREEN LED is illuminated.
    • Adjust 'Lx' setting: The ambient light might be outside the set threshold. Try adjusting the 'Lx' knob.
    • Inspect sensor: Ensure the sensor is clean, unobstructed, and correctly wired.
  • Incorrect switching sensitivity:
    • Recalibrate 'Lx' setting: Fine-tune the 'Lx' knob to match desired light levels.
    • Check sensor placement: Relocate the sensor if it's exposed to unintended light sources or shadows.
    • For GRB8-02, verify 'x1/x10' switch setting matches the required illumination range.
  • Intermittent switching:
    • The 2-minute delay is designed to prevent this. If it persists, check for unstable power supply or environmental factors causing rapid light changes.
  • Sensor cable issues:
    • If the sensor cable has been extended, ensure the extension is properly connected and uses appropriate wiring to avoid signal degradation.

6. Specifications

Technical Parameters:

Parameter GRB8-01 GRB8-02
FunctionTwilight switchTwilight switch
Supply terminalsL-NL-N
Rated supply voltageAC 110V-240VAC 110V-240V
Rated supply frequency50/60Hz50/60Hz
Burdenmax 2VAmax 2VA
Supply voltage tolerance-15%; +10%-15%; +10%
Illumination range1-100Lx1-1000Lx, 10-10000Lx
FunctionON-AUTO-OFFON-x1-x10-OFF
Supply indicationgreen LEDgreen LED
Tolerance sensor±35%±35%
Delay time2min2min
Output1xSPST1xSPST
Current rating16A/AC116A/AC1
Switching voltage250VAC/24VDC250VAC/24VDC
Min.breaking capacity DC500mW500mW
Output indicationred LEDred LED
Mechanical life1x1071x107
Electrical life (AC1)1x1051x105
Operating temperature-20°C to +55°C (-4°F to 131°F)-20°C to +55°C (-4°F to 131°F)
Storage temperature-35°C to +75°C (-22°F to 158°F)-35°C to +75°C (-22°F to 158°F)
Mounting/DIN railDIN rail EN/IEC 60715DIN rail EN/IEC 60715
Protection degreeIP40 for front panel/IP20 terminalsIP40 for front panel/IP20 terminals
Operating positionanyany
Overvoltage categoryIII.III.
Pollution degree22
Max. cable size (mm²)solid wire max.1x2.5 or 2x1.5 / with sleeve max.1x2.5 (AWG 12)solid wire max.1x2.5 or 2x1.5 / with sleeve max.1x2.5 (AWG 12)
Tightening torque0.8N.m0.8N.m

Dimensions (mm):

GRB8-01 and GRB8-02 Dimensions Diagram
Figure 7: Dimensions for GRB8-01 and GRB8-02 models.

7. User Tips

  • Post-Installation Check: After installation, always verify that the device functions correctly by testing the ON, AUTO, and OFF modes.
  • Sensor Cable Extension: The sensor cable can be extended up to 50 meters. Ensure you use appropriate wiring for the extension to maintain signal integrity.
  • Model Verification: Double-check the model number (GRB8-01 or GRB8-02) before installation to ensure it matches your requirements, especially regarding illumination range.
  • Packaging: The product typically arrives well-packaged and in good condition. Keep the original packaging for potential future transport or storage.

8. Warranty and Support

GEYA products are certified to required industry standards, including CCC, CE, CB, SAA, SEMKO, TUV, and Rosh, ensuring quality and compliance. For any technical assistance, warranty claims, or support, please contact your supplier or GEYA customer service.

For further details, you may refer to the official user manual PDF: GEYA GRB8 User Manual (PDF).

GEYA Company Overview:

GEYA Electric, established in 2007, is a private-owned enterprise specializing in R&D, manufacturing, and sales of low-voltage electrical and automatic controlling products. The company is committed to top quality and constant innovation, offering a wide range of products including MCBs, MCCBs, ELCBs, Isolators, Contactors, Relays, Timers, and VFDs.

Video 1: GEYA Company Introduction, showcasing manufacturing processes and product range.

© 2023 GEYA Electrical Co., Ltd. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.