GEYA GRT8-2T

Contents

GEYA GRT8-2T Double Delay on Time Relay

Model: GRT8-2T

1. Introduction

The GEYA GRT8-2T is a double delay on time relay designed for various industrial and home automation applications. It features two independent time relays (t1 and t2) within a single module, allowing for precise control of electrical circuits. This manual provides essential information for the safe and effective installation, operation, and maintenance of your GRT8-2T relay.

2. Safety Information

Always observe the following safety precautions to prevent injury and damage to the device:

  • Ensure power is disconnected before installation, wiring, or maintenance.
  • Installation should be performed by qualified personnel in accordance with local electrical codes.
  • Do not exceed the specified voltage and current ratings.
  • Avoid exposing the device to moisture, extreme temperatures, or corrosive environments.
  • This device operates with low voltage (below 50Vac or 75Vdc) for certain models, but always treat electrical connections with caution.

3. Product Overview

The GRT8-2T is a 1-MODULE DIN rail mountable time relay. It features two independently adjustable delay-on timers (t1 and t2) and provides 2 SPDT (Single Pole Double Throw) output contacts. The relay status is indicated by green and red LEDs.

3.1. Key Features

  • Function: Double Delay ON (two time relays in one module).
  • Time Ranges: 0.1s - 10 days, divided into 10 selectable ranges (0.1s-1s, 1s-10s, 0.1min-1min, 1min-10min, 0.1h-1h, 1h-10hrs, 0.1 day-1 day, 1 day-10 days, ON, OFF).
  • Adjustability: Times t1 and t2 are independently adjustable via potentiometers.
  • Output: 2 x SPDT (Single Pole Double Throw) contacts, rated 16A/AC1.
  • Voltage Options: Available in AC230V or AC/DC12-240V.
  • Indicators: Green LED for supply indication (Un), Red LED for output indication (R).
  • Mounting: DIN rail type (EN/IEC 60715).
  • Certifications: CE, CB, CCC, ROHS.

3.2. Component Identification

Detailed function diagram and component labels for GEYA GRT8-2T relay.
Figure 1: Function Diagram and Component Labels
  • A1, S, A2: Supply Terminals, Trigger Terminal
  • Un (Green LED): Supply Indication
  • R (Red LED): Output Indication
  • t1 Time Range Setting: Knob for setting the first delay time (0.1s-10days, ON, OFF).
  • Time Percentage Setting: Knob for fine-tuning the percentage of t1.
  • t2 Time Range Setting: Knob for setting the second delay time (0.1s-10days, ON, OFF).
  • Time Percentage Setting: Knob for fine-tuning the percentage of t2.
  • Model No: GRT8-2T
  • 15, 16, 18: First Changeover Contact (16A/AC1)
  • 25, 26, 28: Second Changeover Contact (16A/AC1)

4. Technical Specifications

Technical data table for GEYA GRT8-2T Double Delay on Time Relay.
Figure 2: Technical Parameters for GRT8-2T
GRT8-2T Technical Parameters
ParameterGRT8-2T (AC/DC 12-240V)GRT8-2T (AC230V)
Function2x Delay ON
Supply terminalsA1-A2
Voltage rangeAC/DC 12-240V (50-60Hz)AC 230V (50-60Hz)
BurdenAC 0.09-3VA / DC 0.05-1.7W
Power inputAC max.6VA / 1.9W
Supply voltage tolerance-15%; +10%
Supply indicationGreen LED
Time ranges0.1s-10days, ON, OFF
Time settingPotentiometer
Time deviation10% - mechanical setting
Repeat accuracy0.2% - set value stability
Temperature coefficient0.05%/°C, at=20°C (0.05%°F, at=68°F)
Output2 x SPDT
Current rating16A / AC1
Switching voltage250VAC / 24VDC
Min. breaking capacity DC500mW
Output indicationRed LED
Mechanical life1 x 107
Electrical life (AC1)1 x 105
Reset timemax. 200ms
Operating temperature-20°C to +55°C (-4°F to 131°F)
Storage temperature-35°C to +75°C (-22°F to 158°F)
MountingDin rail EN/IEC 60715
Protection degreeIP40 for front panel / IP20 terminals
Operating positionAny
Overvoltage categoryIII.
Pollution degree2
Max. cable size (mm2)Solid wire max.1x2.5 or 2x1.5 / with sleeve max.1x2.5 (AWG 12)
Dimensions90 x 18 x 64mm

5. Setup and Installation

5.1. Mounting

The GRT8-2T relay is designed for DIN rail mounting (EN/IEC 60715). Simply clip the device onto a standard 35mm DIN rail in your electrical enclosure.

5.2. Wiring

Ensure all power is disconnected before proceeding with wiring. Use appropriate wire gauges for the rated current (max. 1x2.5mm² solid wire or 2x1.5mm² with sleeve). Tighten terminals securely.

Wiring diagram for GEYA GRT8-2T with AC230V supply.
Figure 3: Wiring Diagram (AC230V)
Wiring diagram for GEYA GRT8-2T with AC/DC12V-240V supply.
Figure 4: Wiring Diagram (AC/DC12V-240V)
Example application wiring diagram for GEYA GRT8-2T controlling multiple loads.
Figure 5: Example Application Wiring Diagram

Terminal Connections:

  • A1, A2: Supply voltage input.
  • S: Trigger input (for some functions, this may be used to initiate the timing sequence).
  • 15, 16, 18: Output contacts for the first relay (Common, Normally Closed, Normally Open).
  • 25, 26, 28: Output contacts for the second relay (Common, Normally Closed, Normally Open).

6. Operating Instructions

6.1. Time Setting

The GRT8-2T features two sets of rotary potentiometers for setting the time ranges (t1 and t2) and their respective percentages. Each time range knob allows selection from 0.1s to 10 days, including ON and OFF modes. The percentage knob provides fine-tuning within the selected range.

To set the time:

  1. Select the desired time range (e.g., 1s-10s, 1min-10min) using the upper (t1) and lower (t2) range selector knobs.
  2. Adjust the corresponding percentage knob (0-100%) to achieve the precise delay time within the selected range.

6.2. LED Indicators

  • Green LED (Un): Illuminates when the supply voltage is present.
  • Red LED (R): Illuminates when the output relay is activated (contacts 15-18 and 25-28 are closed).

6.3. Function Description (Double Delay ON)

When the supply voltage is connected to terminals A1-A2, both timers t1 and t2 start simultaneously. After the set time t1 has elapsed, the first output relay (15-18) activates. After the set time t2 has elapsed, the second output relay (25-28) activates. Both relays remain activated as long as the supply voltage is present.

7. Maintenance

The GEYA GRT8-2T is designed for long-term, reliable operation with minimal maintenance. However, regular checks can help ensure optimal performance:

  • Periodically inspect the terminals for secure connections.
  • Ensure the device is free from dust and debris.
  • Check for any signs of overheating or physical damage.
  • Verify that the LED indicators are functioning correctly.

Always disconnect power before performing any maintenance.

8. Troubleshooting

Common Troubleshooting Steps
ProblemPossible CauseSolution
Green LED (Un) not litNo supply voltage or incorrect wiring.Check power supply and wiring connections to A1-A2.
Red LED (R) not lit after delayIncorrect time setting, faulty load, or open circuit in load.Verify time settings. Check the load and its wiring. Test the relay output contacts.
Inaccurate timingIncorrect time range/percentage setting.Re-adjust time range and percentage knobs carefully. Refer to specifications for accuracy.
Relay clicks but load doesn't activateFaulty load or wiring to load.Check the load device and its connections to the relay output terminals (15-18, 25-28).

9. User Tips

  • For applications requiring precise timing, consider testing the set delay times with a stopwatch before final deployment.
  • When replacing an old relay, ensure the new GRT8-2T model matches the voltage and contact configuration of the original unit.
  • Keep the device in a well-ventilated area to prevent overheating, especially in enclosed panels.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Ensure you have your product model and purchase details available.

An official user manual in PDF format is available for download: GEYA GRT8-2T User Manual (PDF)

11. Company Overview Video

Learn more about GEYA Electrical Co., Ltd. and their manufacturing processes:

Video: GEYA Company Introduction and Manufacturing Process

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.