Advantage Controls Mega Tron Controller

Overview
The MegaTron controller supports BACnet communications with Building Management Systems and WebAdvantage. BACnet uses an object-oriented model so systems can interoperate over shared networks to exchange control/status functions.
Conformance & Object Support
- Applications Software Version: JA.16.0 and higher
- Firmware Revision: JA.16.0 and higher
- BACnet Protocol Revision: 24
- BACnet Standardized Device Profile (Annex L): BACnet Application Specific Controller (B-ASC)
- BACnet Interoperability Building Blocks Supported (Annex K): DS-RP-B, DM-DDB-B, DM-DCC-B, DM-RD-B
- Data Link Layer Options: BACnet IP (Annex J)
- Character Set Supported: ANSI X3.4
Object/property support matrix: “See table 1-1 Object/Property Support Matrix.” (The table content is shown as property support markers but is not enumerated as concrete max values in the source excerpt.)
Example object instance summaries (examples shown in source excerpt): Binary Input objects BI-000 to BI-003; Binary Value objects BV-012 to BV-273 (multiple alarm/monitor functions); Analog Input objects AI-000 to at least AI-071 shown; Analog Value objects AV-000 to at least AV-126 shown; Multi-State Value objects MSV-000 to MSV-019 shown.
Quick Setup Steps
- Open setup menus: Press Setup/Run, then CONFIGURE, NETWORK, SETTINGS.
- Select BACnet: Press BAC. If options are not visible, enable the dual network card (source note).
- Enter instance/port: Enter the DEVICE INSTANCE and PORT. Press Enter to accept on each.
- Reset communications card: Press RESET, then press Enter to accept; wait for the communications card reset countdown.
- Reboot controller: After reset, cycle power to the controller.
- Set device identifier (MegaTron XS): Go to Configure menu → Network settings → BAC and enter the device object identifier. The device object instance number range is 0 to 4194303, and 4194303 is described as “unconfigured” and not a valid device instance number.
BACnet Introduction
- The MegaTron controller is capable of connecting to the WebAdvantage Server and most Building Management Systems. The WebAdvantage service requires a gateway to the internet with firewall and security rules in place. The
- Building Management System needs to be on the same subnet to properly receive traffic from the MegaTron. This may require some advanced routing of network traffic within the network wiring or programming of advanced switching equipment. The datatraffic for both is provided via the same Ethernet cable coming from the MegaTron.
- The BACnet protocol allows interfacing with more customizable PC applications using HMI/SCADA and stand-alone HMI systems
BACnet Overview
- BACnet is an American National Standard. The BACnet protocol allows the creation of an automation and controls system which may interoperate with other BACnet systems. In BACnet terms, interoperate means that two or more
- BACnet-speaking computer systems may share the same communications networks, and ask each other to perform various functions on a peer-to-peer basis.
- BACnet’s flexibility has two important benefits: vendor-independence and forward-compatibility with future generations of systems. This is accomplished using an object-oriented approach for representing all information within each controller. Since BACnet is based on standards, it provides maximum benefits for both the vendor who designs BACnet systems, and the specifier or owner of those systems.
Protocol Implementation
- Applications Software Version: JA.16.0 and higher
- Firmware Revision: JA.16.0 and higher
- BACnet Protocol Revision: 24
- BACnet Standardized Device Profile (Annex L): BACnet Application Specific Controller (B-ASC) BACnet Interoperability Building Blocks Supported (Annex K):
- DS-RP-B
- DM-DDB-B
- DM-DCC-B
- DM-RD-B
- Standard Object Types Supported: See table 1-1 “Object/Property Support Matrix”. Data Link Layer Options: BACnet IP, (Annex J)
- Character Set Supported: ANSI X3.4
Connecting
- This guide is designed to help with connecting a BACnet enabled MegaTron to a local BMS.
- Note: Screens may vary slightly between models.
BACnet Setup
- Step 1: Press Setup/Run, CONFIGURE, NETWORK, SETTINGS. (See figures 1, 2, 3 and 4. H26 dual cards add figure 3B. H26 only available for MegaTron MT.)
- Step 2: Press BAC. (See figure 4.) Note: If these options are not visible, the dual network card needs to be enabled. See enabling dual network card to continue setup.
- Step 3: Enter the DEVICE INSTANCE and PORT. Press Enter to accept on each. (See figure 6.)
- Step 4: Press RESET and then press Enter to accept. The communications card will reset after a short countdown. (See figures 7 and 8.)
- Step 5: After the communications card has been reset cycle power to the controller.

MegaTron XS Setup

- The MegaTron XS will be a “device object” on the particular BACnet network. Each device object (your MegaTron XS) must have an object identifier that is unique network wide. The device object instance number is normally configured on site after the device is installed. The device object instance number range is between 0 and 4194303. Note that 4194303 is known as “unconfigured” and is not really a valid device instance number. All devices are required to respond with their own Device object instance number when 4194303 is requested.
- To enter your device object identifier, go to the Configure menu in the MegaTron XS and select the Network settings. Then select BAC.
Object Definitions
- Object / Property Support Matrix (Table 1-1)
|
Property |
Object Type | |||||
| Device | Binary Input | Binary Value | Analog Input | Analog Value | Multi-State Value | |
| Object Identifier | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Object Name | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Object Type | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| Description | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
| System Status | ✓ | |||||
| Vendor Name | ✓ | |||||
| Vendor Identifier | ✓ | |||||
| Model Name | ✓ | |||||
| Firmware Revision | ✓ | |||||
| App. Software Revision | ✓ | |||||
| Protocol Version | ✓ | |||||
| Protocol Revision | ✓ | |||||
| Services Supported | ✓ | |||||
| Object Types Supported | ✓ | |||||
| Object List | ✓ | |||||
| Max APDU Length | ✓ | |||||
| Segmentation Support | ✓ | |||||
| APDU Timeout | ✓ | |||||
| Number APDU Retries | ✓ | |||||
| Database Revision | ✓ | |||||
| Present Value | ✓ | ✓ | ✓ | ✓ | ✓ | |
| Status Flags | ✓ | ✓ | ✓ | ✓ | ✓ | |
| Event State | ✓ | ✓ | ✓ | ✓ | ✓ | |
| Out-of-Service | ✓ | ✓ | ✓ | ✓ | ✓ | |
| Units | ✓ | ✓ | ||||
| Polarity | ✓ | ✓ | ||||
| Number of States | ✓ | |||||
| State Text | ✓ |
Binary Input Object Instance Summary (Table 1-2)
| Instance ID | Object Name | Purpose | Present Value – Access |
| 0 | BI-000 | System #1 – Flow Switch | Read Only |
| 1 | BI-001 | System #2 – Flow Switch | Read Only |
| 2 | BI-002 | System #3 – Flow Switch | Read Only |
| 3 | BI-003 | System #4 – Flow Switch | Read Only |
Binary Value Object Instance Summary (Table 1-3)
| Instance ID | Object Name | Purpose | Present Value – Access |
| 12 | BV-012 | System #1 – Conductivity High Alarm | Read Only |
| 13 | BV-013 | System #1 – Conductivity Low Alarm | Read Only |
| 14 | BV-014 | System #1 – Conductivity Limit Alarm | Read Only |
| 15 | BV-015 | System #1 – pH High Alarm | Read Only |
| 16 | BV-016 | System #1 – pH Low Alarm | Read Only |
| 17 | BV-017 | System #1 – pH Limit Alarm | Read Only |
| 18 | BV-018 | System #1 – ORP High Alarm | Read Only |
| 19 | BV-019 | System #1 – ORP Low Alarm | Read Only |
| 20 | BV-020 | System #1 – ORP Limit Alarm | Read Only |
| 21 | BV-021 | System #1 – S. Temp High Alarm | Read Only |
| 22 | BV-022 | System #1 – S. Temp Low Alarm | Read Only |
| 23 | BV-023 | System #1 – M. Temp High Alarm | Read Only |
| 24 | BV-024 | System #1 – M. Temp Low Alarm | Read Only |
| 25 | BV-025 | System #1 – D. Temp High Alarm | Read Only |
| 26 | BV-026 | System #1 – D. Temp Low Alarm | Read Only |
| 27 | BV-027 | System #1 – No Flow Alarm | Read Only |
| 28 | BV-028 | System #1 – Digital Input 1 Alarm | Read Only |
| 29 | BV-029 | System #1 – Digital Input 2 Alarm | Read Only |
| 30 | BV-030 | System #1 – Digital Input 3 Alarm | Read Only |
| 31 | BV-031 | System #1 – Digital Input 4 Alarm | Read Only |
| 32 | BV-032 | System #1 – Digital Input 5 Alarm | Read Only |
| 34 | BV-034 | System #1 – M. Conductivity High Alarm | Read Only |
| 35 | BV-035 | System #1 – M. Conductivity Low Alarm | Read Only |
| 36 | BV-036 | System #1 – M. Conductivity Limit Alarm | Read Only |
| 37 | BV-037 | System #1 – Notepad 1 High Alarm | Read Only |
| 38 | BV-038 | System #1 – Notepad 2 High Alarm | Read Only |
| 39 | BV-039 | System #1 – Notepad 3 High Alarm | Read Only |
| 40 | BV-040 | System #1 – Notepad 4 High Alarm | Read Only |
| 41 | BV-041 | System #1 – Notepad 5 High Alarm | Read Only |
| 42 | BV-042 | System #1 – Notepad 6 High Alarm | Read Only |
| 43 | BV-043 | System #1 – Notepad 7 High Alarm | Read Only |
| 44 | BV-044 | System #1 – Notepad 8 High Alarm | Read Only |
| 45 | BV-045 | System #1 – Notepad 9 High Alarm | Read Only |
| 46 | BV-046 | System #1 – Notepad 10 High Alarm | Read Only |
| 47 | BV-047 | System #1 – Notepad 1 Low Alarm | Read Only |
| 48 | BV-048 | System #1 – Notepad 2 Low Alarm | Read Only |
| 49 | BV-049 | System #1 – Notepad 3 Low Alarm | Read Only |
| 50 | BV-050 | System #1 – Notepad 4 Low Alarm | Read Only |
| 51 | BV-051 | System #1 – Notepad 5 Low Alarm | Read Only |
| 52 | BV-052 | System #1 – Notepad 6 Low Alarm | Read Only |
| 53 | BV-053 | System #1 – Notepad 7 Low Alarm | Read Only |
| 54 | BV-054 | System #1 – Notepad 8 Low Alarm | Read Only |
| 55 | BV-055 | System #1 – Notepad 9 Low Alarm | Read Only |
| 56 | BV-056 | System #1 – Notepad 10 Low Alarm | Read Only |
| 57 | BV-057 | System #1 – Notepad 1 Time Alarm | Read Only |
| 58 | BV-058 | System #1 – Notepad 2 Time Alarm | Read Only |
| 59 | BV-059 | System #1 – Notepad 3 Time Alarm | Read Only |
| 60 | BV-060 | System #1 – Notepad 4 Time Alarm | Read Only |
| 61 | BV-061 | System #1 – Notepad 5 Time Alarm | Read Only |
| 62 | BV-062 | System #1 – Notepad 6 Time Alarm | Read Only |
| 63 | BV-063 | System #1 – Notepad 7 Time Alarm | Read Only |
| 64 | BV-064 | System #1 – Notepad 8 Time Alarm | Read Only |
| 65 | BV-065 | System #1 – Notepad 9 Time Alarm | Read Only |
| 66 | BV-066 | System #1 – Notepad 10 Time Alarm | Read Only |
| 81 | BV-081 | System #2 – Conductivity High Alarm | Read Only |
| 82 | BV-082 | System #2 – Conductivity Low Alarm | Read Only |
| 83 | BV-083 | System #2 – Conductivity Limit Alarm | Read Only |
| 84 | BV-084 | System #2 – pH High Alarm | Read Only |
| 85 | BV-085 | System #2 – pH Low Alarm | Read Only |
| 86 | BV-086 | System #2 – pH Limit Alarm | Read Only |
| 87 | BV-087 | System #2 – ORP High Alarm | Read Only |
| 88 | BV-088 | System #2 – ORP Low Alarm | Read Only |
| 89 | BV-089 | System #2 – ORP Limit Alarm | Read Only |
| 90 | BV-090 | System #2 – S. Temp High Alarm | Read Only |
| 91 | BV-091 | System #2 – S. Temp Low Alarm | Read Only |
| 92 | BV-092 | System #2 – M. Temp High Alarm | Read Only |
| 93 | BV-093 | System #2 – M. Temp Low Alarm | Read Only |
| 94 | BV-094 | System #2 – D. Temp High Alarm | Read Only |
| 95 | BV-095 | System #2 – D. Temp Low Alarm | Read Only |
| 96 | BV-096 | System #2 – No Flow Alarm | Read Only |
| 97 | BV-097 | System #2 – Digital Input 1 Alarm | Read Only |
| 98 | BV-098 | System #2 – Digital Input 2 Alarm | Read Only |
| 99 | BV-099 | System #2 – Digital Input 3 Alarm | Read Only |
| 100 | BV-100 | System #2 – Digital Input 4 Alarm | Read Only |
| 101 | BV-101 | System #2 – Digital Input 5 Alarm | Read Only |
| 103 | BV-103 | System #2 – M. Conductivity High Alarm | Read Only |
| 104 | BV-104 | System #2 – M. Conductivity Low Alarm | Read Only |
| 105 | BV-105 | System #2 – M. Conductivity Limit Alarm | Read Only |
| 106 | BV-106 | System #2 – Notepad 1 High Alarm | Read Only |
| 107 | BV-107 | System #2 – Notepad 2 High Alarm | Read Only |
| 108 | BV-108 | System #2 – Notepad 3 High Alarm | Read Only |
| 109 | BV-109 | System #2 – Notepad 4 High Alarm | Read Only |
| 110 | BV-110 | System #2 – Notepad 5 High Alarm | Read Only |
| 111 | BV-111 | System #2 – Notepad 6 High Alarm | Read Only |
| 112 | BV-112 | System #2 – Notepad 7 High Alarm | Read Only |
| 113 | BV-113 | System #2 – Notepad 8 High Alarm | Read Only |
| 114 | BV-114 | System #2 – Notepad 9 High Alarm | Read Only |
| 115 | BV-115 | System #2 – Notepad 10 High Alarm | Read Only |
| 116 | BV-116 | System #2 – Notepad 1 Low Alarm | Read Only |
| 117 | BV-117 | System #2 – Notepad 2 Low Alarm | Read Only |
| 118 | BV-118 | System #2 – Notepad 3 Low Alarm | Read Only |
| 119 | BV-119 | System #2 – Notepad 4 Low Alarm | Read Only |
| 120 | BV-120 | System #2 – Notepad 5 Low Alarm | Read Only |
| 121 | BV-121 | System #2 – Notepad 6 Low Alarm | Read Only |
| 122 | BV-122 | System #2 – Notepad 7 Low Alarm | Read Only |
| 123 | BV-123 | System #2 – Notepad 8 Low Alarm | Read Only |
| 124 | BV-124 | System #2 – Notepad 9 Low Alarm | Read Only |
| 125 | BV-125 | System #2 – Notepad 10 Low Alarm | Read Only |
| 126 | BV-126 | System #2 – Notepad 1 Time Alarm | Read Only |
| 127 | BV-127 | System #2 – Notepad 2 Time Alarm | Read Only |
| 128 | BV-128 | System #2 – Notepad 3 Time Alarm | Read Only |
| 129 | BV-129 | System #2 – Notepad 4 Time Alarm | Read Only |
| 130 | BV-130 | System #2 – Notepad 5 Time Alarm | Read Only |
| 131 | BV-131 | System #2 – Notepad 6 Time Alarm | Read Only |
| 132 | BV-132 | System #2 – Notepad 7 Time Alarm | Read Only |
| 133 | BV-133 | System #2 – Notepad 8 Time Alarm | Read Only |
| 134 | BV-134 | System #2 – Notepad 9 Time Alarm | Read Only |
| 135 | BV-135 | System #2 – Notepad 10 Time Alarm | Read Only |
| 150 | BV-150 | System #3 – Conductivity High Alarm | Read Only |
| 151 | BV-151 | System #3 – Conductivity Low Alarm | Read Only |
| 152 | BV-152 | System #3 – Conductivity Limit Alarm | Read Only |
| 153 | BV-153 | System #3 – pH High Alarm | Read Only |
| 154 | BV-154 | System #3 – pH Low Alarm | Read Only |
| 155 | BV-155 | System #3 – pH Limit Alarm | Read Only |
| 156 | BV-156 | System #3 – ORP High Alarm | Read Only |
| 157 | BV-157 | System #3 – ORP Low Alarm | Read Only |
| 158 | BV-158 | System #3 – ORP Limit Alarm | Read Only |
| 159 | BV-159 | System #3 – S. Temp High Alarm | Read Only |
| 160 | BV-160 | System #3 – S. Temp Low Alarm | Read Only |
| 161 | BV-161 | System #3 – M. Temp High Alarm | Read Only |
| 162 | BV-162 | System #3 – M. Temp Low Alarm | Read Only |
| 163 | BV-163 | System #3 – D. Temp High Alarm | Read Only |
| 164 | BV-164 | System #3 – D. Temp Low Alarm | Read Only |
| 165 | BV-165 | System #3 – No Flow Alarm | Read Only |
| 166 | BV-166 | System #3 – Digital Input 1 Alarm | Read Only |
| 167 | BV-167 | System #3 – Digital Input 2 Alarm | Read Only |
| 168 | BV-168 | System #3 – Digital Input 3 Alarm | Read Only |
| 169 | BV-169 | System #3 – Digital Input 4 Alarm | Read Only |
| 170 | BV-170 | System #3 – Digital Input 5 Alarm | Read Only |
| 172 | BV-172 | System #3 – M. Conductivity High Alarm | Read Only |
| 173 | BV-173 | System #3 – M. Conductivity Low Alarm | Read Only |
| 174 | BV-174 | System #3 – M. Conductivity Limit Alarm | Read Only |
| 175 | BV-175 | System #3 – Notepad 1 High Alarm | Read Only |
| 176 | BV-176 | System #3 – Notepad 2 High Alarm | Read Only |
| 177 | BV-177 | System #3 – Notepad 3 High Alarm | Read Only |
| 178 | BV-178 | System #3 – Notepad 4 High Alarm | Read Only |
| 179 | BV-179 | System #3 – Notepad 5 High Alarm | Read Only |
| 180 | BV-180 | System #3 – Notepad 6 High Alarm | Read Only |
| 181 | BV-181 | System #3 – Notepad 7 High Alarm | Read Only |
| 182 | BV-182 | System #3 – Notepad 8 High Alarm | Read Only |
| 183 | BV-183 | System #3 – Notepad 9 High Alarm | Read Only |
| 184 | BV-184 | System #3 – Notepad 10 High Alarm | Read Only |
| 185 | BV-185 | System #3 – Notepad 1 Low Alarm | Read Only |
| 186 | BV-186 | System #3 – Notepad 2 Low Alarm | Read Only |
| 187 | BV-187 | System #3 – Notepad 3 Low Alarm | Read Only |
| 188 | BV-188 | System #3 – Notepad 4 Low Alarm | Read Only |
| 189 | BV-189 | System #3 – Notepad 5 Low Alarm | Read Only |
| 190 | BV-190 | System #3 – Notepad 6 Low Alarm | Read Only |
| 191 | BV-191 | System #3 – Notepad 7 Low Alarm | Read Only |
| 192 | BV-192 | System #3 – Notepad 8 Low Alarm | Read Only |
| 193 | BV-193 | System #3 – Notepad 9 Low Alarm | Read Only |
| 194 | BV-194 | System #3 – Notepad 10 Low Alarm | Read Only |
| 195 | BV-195 | System #3 – Notepad 1 Time Alarm | Read Only |
| 196 | BV-196 | System #3 – Notepad 2 Time Alarm | Read Only |
| 197 | BV-197 | System #3 – Notepad 3 Time Alarm | Read Only |
| 198 | BV-198 | System #3 – Notepad 4 Time Alarm | Read Only |
| 199 | BV-199 | System #3 – Notepad 5 Time Alarm | Read Only |
| 200 | BV-200 | System #3 – Notepad 6 Time Alarm | Read Only |
| 201 | BV-201 | System #3 – Notepad 7 Time Alarm | Read Only |
| 202 | BV-202 | System #3 – Notepad 8 Time Alarm | Read Only |
| 203 | BV-203 | System #3 – Notepad 9 Time Alarm | Read Only |
| 204 | BV-204 | System #3 – Notepad 10 Time Alarm | Read Only |
| 219 | BV-219 | System #4 – Conductivity High Alarm | Read Only |
| 220 | BV-220 | System #4 – Conductivity Low Alarm | Read Only |
| 221 | BV-221 | System #4 – Conductivity Limit Alarm | Read Only |
| 222 | BV-222 | System #4 – pH High Alarm | Read Only |
| 223 | BV-223 | System #4 – pH Low Alarm | Read Only |
| 224 | BV-224 | System #4 – pH Limit Alarm | Read Only |
| 225 | BV-225 | System #4 – ORP High Alarm | Read Only |
| 226 | BV-226 | System #4 – ORP Low Alarm | Read Only |
| 227 | BV-227 | System #4 – ORP Limit Alarm | Read Only |
| 228 | BV-228 | System #4 – S. Temp High Alarm | Read Only |
| 229 | BV-229 | System #4 – S. Temp Low Alarm | Read Only |
| 230 | BV-230 | System #4 – M. Temp High Alarm | Read Only |
| 231 | BV-231 | System #4 – M. Temp Low Alarm | Read Only |
| 232 | BV-232 | System #4 – D. Temp High Alarm | Read Only |
| 233 | BV-233 | System #4 – D. Temp Low Alarm | Read Only |
| 234 | BV-234 | System #4 – No Flow Alarm | Read Only |
| 235 | BV-235 | System #4 – Digital Input 1 Alarm | Read Only |
| 236 | BV-236 | System #4 – Digital Input 2 Alarm | Read Only |
| 237 | BV-237 | System #4 – Digital Input 3 Alarm | Read Only |
| 238 | BV-238 | System #4 – Digital Input 4 Alarm | Read Only |
| 239 | BV-239 | System #4 – Digital Input 5 Alarm | Read Only |
| 241 | BV-241 | System #4 – M. Conductivity High Alarm | Read Only |
| 242 | BV-242 | System #4 – M. Conductivity Low Alarm | Read Only |
| 243 | BV-243 | System #4 – M. Conductivity Limit Alarm | Read Only |
| 244 | BV-244 | System #4 – Notepad 1 High Alarm | Read Only |
| 245 | BV-245 | System #4 – Notepad 2 High Alarm | Read Only |
| 246 | BV-246 | System #4 – Notepad 3 High Alarm | Read Only |
| 247 | BV-247 | System #4 – Notepad 4 High Alarm | Read Only |
| 248 | BV-248 | System #4 – Notepad 5 High Alarm | Read Only |
| 249 | BV-249 | System #4 – Notepad 6 High Alarm | Read Only |
| 250 | BV-250 | System #4 – Notepad 7 High Alarm | Read Only |
| 251 | BV-251 | System #4 – Notepad 8 High Alarm | Read Only |
| 252 | BV-252 | System #4 – Notepad 9 High Alarm | Read Only |
| 253 | BV-253 | System #4 – Notepad 10 High Alarm | Read Only |
| 254 | BV-254 | System #4 – Notepad 1 Low Alarm | Read Only |
| 255 | BV-255 | System #4 – Notepad 2 Low Alarm | Read Only |
| 256 | BV-256 | System #4 – Notepad 3 Low Alarm | Read Only |
| 257 | BV-257 | System #4 – Notepad 4 Low Alarm | Read Only |
| 258 | BV-258 | System #4 – Notepad 5 Low Alarm | Read Only |
| 259 | BV-259 | System #4 – Notepad 6 Low Alarm | Read Only |
| 260 | BV-260 | System #4 – Notepad 7 Low Alarm | Read Only |
| 261 | BV-261 | System #4 – Notepad 8 Low Alarm | Read Only |
| 262 | BV-262 | System #4 – Notepad 9 Low Alarm | Read Only |
| 263 | BV-263 | System #4 – Notepad 10 Low Alarm | Read Only |
| 264 | BV-264 | System #4 – Notepad 1 Time Alarm | Read Only |
| 265 | BV-265 | System #4 – Notepad 2 Time Alarm | Read Only |
| 266 | BV-266 | System #4 – Notepad 3 Time Alarm | Read Only |
| 267 | BV-267 | System #4 – Notepad 4 Time Alarm | Read Only |
| 268 | BV-268 | System #4 – Notepad 5 Time Alarm | Read Only |
| 269 | BV-269 | System #4 – Notepad 6 Time Alarm | Read Only |
| 270 | BV-270 | System #4 – Notepad 7 Time Alarm | Read Only |
| 271 | BV-271 | System #4 – Notepad 8 Time Alarm | Read Only |
| 272 | BV-272 | System #4 – Notepad 9 Time Alarm | Read Only |
| 273 | BV-273 | System #4 – Notepad 10 Time Alarm | Read Only |
| 232 | BV-232 | System #4 – D. Temp High Alarm | Read Only |
| 233 | BV-233 | System #4 – D. Temp Low Alarm | Read Only |
| 234 | BV-234 | System #4 – No Flow Alarm | Read Only |
| 235 | BV-235 | System #4 – Digital Input 1 Alarm | Read Only |
| 236 | BV-236 | System #4 – Digital Input 2 Alarm | Read Only |
| 237 | BV-237 | System #4 – Digital Input 3 Alarm | Read Only |
| 238 | BV-238 | System #4 – Digital Input 4 Alarm | Read Only |
| 239 | BV-239 | System #4 – Digital Input 5 Alarm | Read Only |
| 241 | BV-241 | System #4 – M. Conductivity High Alarm | Read Only |
| 242 | BV-242 | System #4 – M. Conductivity Low Alarm | Read Only |
| 243 | BV-243 | System #4 – M. Conductivity Limit Alarm | Read Only |
| 244 | BV-244 | System #4 – Notepad 1 High Alarm | Read Only |
| 245 | BV-245 | System #4 – Notepad 2 High Alarm | Read Only |
| 246 | BV-246 | System #4 – Notepad 3 High Alarm | Read Only |
| 247 | BV-247 | System #4 – Notepad 4 High Alarm | Read Only |
| 248 | BV-248 | System #4 – Notepad 5 High Alarm | Read Only |
| 249 | BV-249 | System #4 – Notepad 6 High Alarm | Read Only |
| 250 | BV-250 | System #4 – Notepad 7 High Alarm | Read Only |
| 251 | BV-251 | System #4 – Notepad 8 High Alarm | Read Only |
| 252 | BV-252 | System #4 – Notepad 9 High Alarm | Read Only |
| 253 | BV-253 | System #4 – Notepad 10 High Alarm | Read Only |
| 254 | BV-254 | System #4 – Notepad 1 Low Alarm | Read Only |
| 255 | BV-255 | System #4 – Notepad 2 Low Alarm | Read Only |
| 256 | BV-256 | System #4 – Notepad 3 Low Alarm | Read Only |
| 257 | BV-257 | System #4 – Notepad 4 Low Alarm | Read Only |
| 258 | BV-258 | System #4 – Notepad 5 Low Alarm | Read Only |
| 259 | BV-259 | System #4 – Notepad 6 Low Alarm | Read Only |
| 260 | BV-260 | System #4 – Notepad 7 Low Alarm | Read Only |
| 261 | BV-261 | System #4 – Notepad 8 Low Alarm | Read Only |
| 262 | BV-262 | System #4 – Notepad 9 Low Alarm | Read Only |
| 263 | BV-263 | System #4 – Notepad 10 Low Alarm | Read Only |
| 264 | BV-264 | System #4 – Notepad 1 Time Alarm | Read Only |
| 265 | BV-265 | System #4 – Notepad 2 Time Alarm | Read Only |
| 266 | BV-266 | System #4 – Notepad 3 Time Alarm | Read Only |
| 267 | BV-267 | System #4 – Notepad 4 Time Alarm | Read Only |
| 268 | BV-268 | System #4 – Notepad 5 Time Alarm | Read Only |
| 269 | BV-269 | System #4 – Notepad 6 Time Alarm | Read Only |
| 270 | BV-270 | System #4 – Notepad 7 Time Alarm | Read Only |
| 271 | BV-271 | System #4 – Notepad 8 Time Alarm | Read Only |
| 272 | BV-272 | System #4 – Notepad 9 Time Alarm | Read Only |
| 273 | BV-273 | System #4 – Notepad 10 Time Alarm | Read Only |
| 277 | BV-277 | ma Input 1 High Alarm | Read Only |
| 278 | BV-278 | ma Input 1 Low Alarm | Read Only |
| 280 | BV-280 | ma Input 2 High Alarm | Read Only |
| 281 | BV-281 | ma Input 2 Low Alarm | Read Only |
| 283 | BV-283 | ma Input 3 High Alarm | Read Only |
| 284 | BV-284 | ma Input 3 Low Alarm | Read Only |
| 286 | BV-286 | ma Input 4 High Alarm | Read Only |
| 287 | BV-287 | ma Input 4 Low Alarm | Read Only |
| 289 | BV-289 | ma Input 5 High Alarm | Read Only |
| 290 | BV-290 | ma Input 5 Low Alarm | Read Only |
| 292 | BV-292 | ma Input 6 High Alarm | Read Only |
| 293 | BV-293 | ma Input 6 Low Alarm | Read Only |
| 295 | BV-295 | ma Input 7 High Alarm | Read Only |
| 296 | BV-296 | ma Input 7 Low Alarm | Read Only |
| 298 | BV-298 | ma Input 8 High Alarm | Read Only |
| 299 | BV-299 | ma Input 8 Low Alarm | Read Only |
| 302 | BV-302 | Flow Meter 1 Flow Alarm | Read Only |
| 303 | BV-303 | Flow Meter 1 Flow Verfiy Alarm | Read Only |
| 304 | BV-304 | Flow Meter 1 Volume Alarm | Read Only |
| 305 | BV-305 | Flow Meter 2 Flow Alarm | Read Only |
| 306 | BV-306 | Flow Meter 2 Flow Verfiy Alarm | Read Only |
| 307 | BV-307 | Flow Meter 2 Volume Alarm | Read Only |
| 308 | BV-308 | Flow Meter 3 Flow Alarm | Read Only |
| 309 | BV-309 | Flow Meter 3 Flow Verfiy Alarm | Read Only |
| 310 | BV-310 | Flow Meter 3 Volume Alarm | Read Only |
| 311 | BV-311 | Flow Meter 4 Flow Alarm | Read Only |
| 312 | BV-312 | Flow Meter 4 Flow Verfiy Alarm | Read Only |
| 313 | BV-313 | Flow Meter 4 Volume Alarm | Read Only |
| 314 | BV-314 | Flow Meter 5 Flow Alarm | Read Only |
| 315 | BV-315 | Flow Meter 5 Flow Verfiy Alarm | Read Only |
| 316 | BV-316 | Flow Meter 5 Volume Alarm | Read Only |
| 317 | BV-317 | Flow Meter 6 Flow Alarm | Read Only |
| 318 | BV-318 | Flow Meter 6 Flow Verfiy Alarm | Read Only |
| 319 | BV-319 | Flow Meter 6 Volume Alarm | Read Only |
| 320 | BV-320 | Flow Meter 7 Flow Alarm | Read Only |
| 321 | BV-321 | Flow Meter 7 Flow Verfiy Alarm | Read Only |
| 322 | BV-322 | Flow Meter 7 Volume Alarm | Read Only |
| 323 | BV-323 | Flow Meter 8 Flow Alarm | Read Only |
| 324 | BV-324 | Flow Meter 8 Flow Verfiy Alarm | Read Only |
| 325 | BV-325 | Flow Meter 8 Volume Alarm | Read Only |
| 326 | BV-326 | Flow Meter 9 Flow Alarm | Read Only |
| 327 | BV-327 | Flow Meter 9 Flow Verfiy Alarm | Read Only |
| 328 | BV-328 | Flow Meter 9 Volume Alarm | Read Only |
| 329 | BV-329 | Flow Meter 10 Flow Alarm | Read Only |
| 330 | BV-330 | Flow Meter 10 Flow Verify | Read Only |
| 331 | BV-331 | Flow Meter 10 Volume Alarm | Read Only |
| 332 | BV-332 | Relay 1 Max Hours | Read Only |
| 333 | BV-333 | Relay 2 Max Hours | Read Only |
| 334 | BV-334 | Relay 3 Max Hours | Read Only |
| 335 | BV-335 | Relay 4 Max Hours | Read Only |
| 336 | BV-336 | Relay 5 Max Hours | Read Only |
| 337 | BV-337 | Relay 6 Max Hours | Read Only |
| 338 | BV-338 | Relay 7 Max Hours | Read Only |
| 339 | BV-339 | Relay 8 Max Hours | Read Only |
| 340 | BV-340 | Relay 9 Max Hours | Read Only |
| 341 | BV-341 | Relay 10 Max Hours | Read Only |
| 342 | BV-342 | Relay 11 Max Hours | Read Only |
| 343 | BV-343 | Relay 12 Max Hours | Read Only |
| 344 | BV-344 | Relay 13 Max Hours | Read Only |
| 345 | BV-345 | Relay 14 Max Hours | Read Only |
| 346 | BV-346 | Relay 15 Max Hours | Read Only |
| 347 | BV-347 | Relay 16 Max Hours | Read Only |
| 348 | BV-348 | Relay 17 Max Hours | Read Only |
| 349 | BV-349 | Relay 18 Max Hours | Read Only |
| 350 | BV-350 | Relay 19 Max Hours | Read Only |
| 351 | BV-351 | Relay 20 Max Hours | Read Only |
| 352 | BV-352 | mA Input 1 Limit | Read Only |
| 353 | BV-353 | mA Input 2 Limit | Read Only |
| 354 | BV-354 | mA Input 3 Limit | Read Only |
| 355 | BV-355 | mA Input 4 Limit | Read Only |
| 356 | BV-356 | mA Input 5 Limit | Read Only |
| 357 | BV-357 | mA Input 6 Limit | Read Only |
| 358 | BV-358 | mA Input 7 Limit | Read Only |
| 359 | BV-359 | mA Input 8 Limit | Read Only |
| 360 | BV-360 | mA Input 9 Limit Alarm | Read Only |
| 361 | BV-361 | mA Input 10 Limit Alarm | Read Only |
| 362 | BV-362 | mA Input 11 Limit Alarm | Read Only |
| 363 | BV-363 | mA Input 12 Limit Alarm | Read Only |
| 364 | BV-364 | mA Input 13 Limit Alarm | Read Only |
| 365 | BV-365 | mA Input 14 Limit Alarm | Read Only |
| 366 | BV-366 | mA Input 15 Limit Alarm | Read Only |
| 367 | BV-367 | mA Input 16 Limit Alarm | Read Only |
| 369 | BV-369 | ma Input 9 High Alarm | Read Only |
| 370 | BV-370 | ma Input 9 Low Alarm | Read Only |
| 372 | BV-372 | ma Input 10 High Alarm | Read Only |
| 373 | BV-373 | ma Input 10 Low Alarm | Read Only |
| 375 | BV-375 | ma Input 11 High Alarm | Read Only |
| 376 | BV-376 | ma Input 11 Low Alarm | Read Only |
| 378 | BV-378 | ma Input 12 High Alarm | Read Only |
| 379 | BV-379 | ma Input 12 Low Alarm | Read Only |
| 381 | BV-381 | ma Input 13 High Alarm | Read Only |
| 382 | BV-382 | ma Input 13 Low Alarm | Read Only |
| 384 | BV-384 | ma Input 14 High Alarm | Read Only |
| 385 | BV-385 | ma Input 14 Low Alarm | Read Only |
| 387 | BV-387 | ma Input 15 High Alarm | Read Only |
| 388 | BV-388 | ma Input 15 Low Alarm | Read Only |
| 390 | BV-390 | ma Input 16 High Alarm | Read Only |
| 391 | BV-391 | ma Input 16 Low Alarm | Read Only |
Analog Input Object Instance Summary (Table 1-4)
| Instance ID | Object Name | Purpose | Present Value – Access |
| 0 | AI-000 | System #1 – Conductivity | Read Only |
| 1 | AI-001 | System #2 – Conductivity | Read Only |
| 2 | AI-002 | System #3 – Conductivity | Read Only |
| 3 | AI-003 | System #4 – Conductivity | Read Only |
| 4 | AI-004 | System #1 – M. Conductivity | Read Only |
| 5 | AI-005 | System #2 – M. Conductivity | Read Only |
| 6 | AI-006 | System #3 – M. Conductivity | Read Only |
| 7 | AI-007 | System #4 – M. Conductivity | Read Only |
| 8 | AI-008 | System #1 – pH | Read Only |
| 9 | AI-009 | System #2 – pH | Read Only |
| 10 | AI-010 | System #3 – pH | Read Only |
| 11 | AI-011 | System #4 – pH | Read Only |
| 12 | AI-012 | System #1 – ORP | Read Only |
| 13 | AI-013 | System #2 – ORP | Read Only |
| 14 | AI-014 | System #3 – ORP | Read Only |
| 15 | AI-015 | System #4 – ORP | Read Only |
| 16 | AI-016 | System #1 – S. Temp | Read Only |
| 17 | AI-017 | System #2 – S. Temp | Read Only |
| 18 | AI-018 | System #3 – S. Temp | Read Only |
| 19 | AI-019 | System #4 – S. Temp | Read Only |
| 20 | AI-020 | System #1 – M. Temp | Read Only |
| 21 | AI-021 | System #2 – M. Temp | Read Only |
| 22 | AI-022 | System #3 – M. Temp | Read Only |
| 23 | AI-023 | System #4 – M. Temp | Read Only |
| 24 | AI-024 | Sys #1 – Water Meter #1 – Total Value | Read Only |
| 25 | AI-025 | Sys #2 – Water Meter #1 – Total Value | Read Only |
| 26 | AI-026 | Sys #3 – Water Meter #1 – Total Value | Read Only |
| 27 | AI-027 | Sys #4 – Water Meter #1 – Total Value | Read Only |
| 28 | AI-028 | Sys #1 – Water Meter #2 – Total Value | Read Only |
| 29 | AI-029 | Sys #2 – Water Meter #2 – Total Value | Read Only |
| 30 | AI-030 | Sys #3 – Water Meter #2 – Total Value | Read Only |
| 31 | AI-031 | Sys #4 – Water Meter #2 – Total Value | Read Only |
| 32 | AI-032 | System #1 – M.Cycles | Read Only |
| 33 | AI-033 | System #2 – M.Cycles | Read Only |
| 34 | AI-034 | System #3 – M.Cycles | Read Only |
| 35 | AI-035 | System #4 – M.Cycles | Read Only |
| 36 | AI-036 | 4-20 mA / 0-5V Input #1 – Value | Read Only |
| 37 | AI-037 | 4-20 mA / 0-5V Input #2 – Value | Read Only |
| 38 | AI-038 | 4-20 mA / 0-5V Input #3 – Value | Read Only |
| 39 | AI-039 | 4-20 mA / 0-5V Input #4 – Value | Read Only |
| 40 | AI-040 | 4-20 mA / 0-5V Input #5 – Value | Read Only |
| 41 | AI-041 | 4-20 mA / 0-5V Input #6 – Value | Read Only |
| 42 | AI-042 | 4-20 mA / 0-5V Input #7 – Value | Read Only |
| 43 | AI-043 | 4-20 mA / 0-5V Input #8 – Value | Read Only |
| 44 | AI-044 | Flow Meter #1 – Contact Value | Read Only |
| 45 | AI-045 | Flow Meter #2 – Contact Value | Read Only |
| 46 | AI-046 | Flow Meter #3 – Contact Value | Read Only |
| 47 | AI-047 | Flow Meter #4 – Contact Value | Read Only |
| 48 | AI-048 | Flow Meter #5 – Contact Value | Read Only |
| 49 | AI-049 | Flow Meter #6 – Contact Value | Read Only |
| 50 | AI-050 | Flow Meter #7 – Contact Value | Read Only |
| 51 | AI-051 | Flow Meter #8 – Contact Value | Read Only |
| 52 | AI-052 | Flow Meter #9 – Contact Value | Read Only |
| 53 | AI-053 | Flow Meter #10 – Contact Value | Read Only |
| 54 | AI-054 | Flow Meter #1 – Flow Rate (per MIN) | Read Only |
| 55 | AI-055 | Flow Meter #2 – Flow Rate (per MIN) | Read Only |
| 56 | AI-056 | Flow Meter #3 – Flow Rate (per MIN) | Read Only |
| 57 | AI-057 | Flow Meter #4 – Flow Rate (per MIN) | Read Only |
| 58 | AI-058 | Flow Meter #5 – Flow Rate (per MIN) | Read Only |
| 59 | AI-059 | Flow Meter #6 – Flow Rate (per MIN) | Read Only |
| 60 | AI-060 | Flow Meter #7 – Flow Rate (per MIN) | Read Only |
| 61 | AI-061 | Flow Meter #8 – Flow Rate (per MIN) | Read Only |
| 62 | AI-062 | Flow Meter #9 – Flow Rate (per MIN) | Read Only |
| 63 | AI-063 | Flow Meter #10 – Flow Rate (per MIN) | Read Only |
| 64 | AI-064 | 4-20 mA / 0-5V Input #9 – Value | Read Only |
| 65 | AI-065 | 4-20 mA / 0-5V Input #10 – Value | Read Only |
| 66 | AI-066 | 4-20 mA / 0-5V Input #11 – Value | Read Only |
| 67 | AI-067 | 4-20 mA / 0-5V Input #12 – Value | Read Only |
| 68 | AI-068 | 4-20 mA / 0-5V Input #13 – Value | Read Only |
| 69 | AI-069 | 4-20 mA / 0-5V Input #14 – Value | Read Only |
| 70 | AI-070 | 4-20 mA / 0-5V Input #15 – Value | Read Only |
| 71 | AI-071 | 4-20 mA / 0-5V Input #16 – Value | Read Only |
Analog Value Object Instance Summary (Table 1-5)
| Instance ID | Object Name | Purpose | Present Value – Access |
| 0 | AV-000 | System #1 – Conductivity Setpoint #1 | Read / Write |
| 1 | AV-001 | System #2 – Conductivity Setpoint #1 | Read / Write |
| 2 | AV-002 | System #3 – Conductivity Setpoint #1 | Read / Write |
| 3 | AV-003 | System #4 – Conductivity Setpoint #1 | Read / Write |
| 4 | AV-004 | System #1 – Conductivity Setpoint #2 | Read / Write |
| 5 | AV-005 | System #2 – Conductivity Setpoint #2 | Read / Write |
| 6 | AV-006 | System #3 – Conductivity Setpoint #2 | Read / Write |
| 7 | AV-007 | System #4 – Conductivity Setpoint #2 | Read / Write |
| 8 | AV-008 | System #1 – Conductivity High Alarm | Read / Write |
| 9 | AV-009 | System #2 – Conductivity High Alarm | Read / Write |
| 10 | AV-010 | System #3 – Conductivity High Alarm | Read / Write |
| 11 | AV-011 | System #4 – Conductivity High Alarm | Read / Write |
| 12 | AV-012 | System #1 – Conductivity Low Alarm | Read / Write |
| 13 | AV-013 | System #2 – Conductivity Low Alarm | Read / Write |
| 14 | AV-014 | System #3 – Conductivity Low Alarm | Read / Write |
| 15 | AV-015 | System #4 – Conductivity Low Alarm | Read / Write |
| 16 | AV-016 | System #1 – M. Conductivity Setpoint | Read / Write |
| 17 | AV-017 | System #2 – M. Conductivity Setpoint | Read / Write |
| 18 | AV-018 | System #3 – M. Conductivity Setpoint | Read / Write |
| 19 | AV-019 | System #4 – M. Conductivity Setpoint | Read / Write |
| 20 | AV-020 | System #1 – M. Conductivity High Alarm | Read / Write |
| 21 | AV-021 | System #2 – M. Conductivity High Alarm | Read / Write |
| 22 | AV-022 | System #3 – M. Conductivity High Alarm | Read / Write |
| 23 | AV-023 | System #4 – M. Conductivity High Alarm | Read / Write |
| 24 | AV-024 | System #1 – M. Conductivity Low Alarm | Read / Write |
| 25 | AV-025 | System #2 – M. Conductivity Low Alarm | Read / Write |
| 26 | AV-026 | System #3 – M. Conductivity Low Alarm | Read / Write |
| 27 | AV-027 | System #4 – M. Conductivity Low Alarm | Read / Write |
| 28 | AV-028 | System #1 – pH Setpoint #1 | Read / Write |
| 29 | AV-029 | System #2 – pH Setpoint #1 | Read / Write |
| 30 | AV-030 | System #3 – pH Setpoint #1 | Read / Write |
| 31 | AV-031 | System #4 – pH Setpoint #1 | Read / Write |
| 32 | AV-032 | System #1 – pH Setpoint #2 | Read / Write |
| 33 | AV-033 | System #2 – pH Setpoint #2 | Read / Write |
| 34 | AV-034 | System #3 – pH Setpoint #2 | Read / Write |
| 35 | AV-035 | System #4 – pH Setpoint #2 | Read / Write |
| 36 | AV-036 | System #1 – pH High Alarm | Read / Write |
| 37 | AV-037 | System #2 – pH High Alarm | Read / Write |
| 38 | AV-038 | System #3 – pH High Alarm | Read / Write |
| 39 | AV-039 | System #4 – pH High Alarm | Read / Write |
| 40 | AV-040 | System #1 – pH Low Alarm | Read / Write |
| 41 | AV-041 | System #2 – pH Low Alarm | Read / Write |
| 42 | AV-042 | System #3 – pH Low Alarm | Read / Write |
| 43 | AV-043 | System #4 – pH Low Alarm | Read / Write |
| 44 | AV-044 | System #1 – ORP Setpoint #1 | Read / Write |
| 45 | AV-045 | System #2 – ORP Setpoint #1 | Read / Write |
| 46 | AV-046 | System #3 – ORP Setpoint #1 | Read / Write |
| 47 | AV-047 | System #4 – ORP Setpoint #1 | Read / Write |
| 48 | AV-048 | System #1 – ORP Setpoint #2 | Read / Write |
| 49 | AV-049 | System #2 – ORP Setpoint #2 | Read / Write |
| 50 | AV-050 | System #3 – ORP Setpoint #2 | Read / Write |
| 51 | AV-051 | System #4 – ORP Setpoint #2 | Read / Write |
| 52 | AV-052 | System #1 – ORP High Alarm | Read / Write |
| 53 | AV-053 | System #2 – ORP High Alarm | Read / Write |
| 54 | AV-054 | System #3 – ORP High Alarm | Read / Write |
| 55 | AV-055 | System #4 – ORP High Alarm | Read / Write |
| 56 | AV-056 | System #1 – ORP Low Alarm | Read / Write |
| 57 | AV-057 | System #2 – ORP Low Alarm | Read / Write |
| 58 | AV-058 | System #3 – ORP Low Alarm | Read / Write |
| 59 | AV-059 | System #4 – ORP Low Alarm | Read / Write |
| 60 | AV-060 | System #1 – S. Temp Setpoint | Read / Write |
| 61 | AV-061 | System #2 – S. Temp Setpoint | Read / Write |
| 62 | AV-062 | System #3 – S. Temp Setpoint | Read / Write |
| 63 | AV-063 | System #4 – S. Temp Setpoint | Read / Write |
| 64 | AV-064 | System #1 – S. Temp High Alarm | Read / Write |
| 65 | AV-065 | System #2 – S. Temp High Alarm | Read / Write |
| 66 | AV-066 | System #3 – S. Temp High Alarm | Read / Write |
| 67 | AV-067 | System #4 – S. Temp High Alarm | Read / Write |
| 68 | AV-068 | System #1 – S. Temp Low Alarm | Read / Write |
| 69 | AV-069 | System #2 – S. Temp Low Alarm | Read / Write |
| 70 | AV-070 | System #3 – S. Temp Low Alarm | Read / Write |
| 71 | AV-071 | System #4 – S. Temp Low Alarm | Read / Write |
| 72 | AV-072 | System #1 – M. Temp Setpoint | Read / Write |
| 73 | AV-073 | System #2 – M. Temp Setpoint | Read / Write |
| 74 | AV-074 | System #3 – M. Temp Setpoint | Read / Write |
| 75 | AV-075 | System #4 – M. Temp Setpoint | Read / Write |
| 76 | AV-076 | System #1 – M. Temp High Alarm | Read / Write |
| 77 | AV-077 | System #2 – M. Temp High Alarm | Read / Write |
| 78 | AV-078 | System #3 – M. Temp High Alarm | Read / Write |
| 79 | AV-079 | System #4 – M. Temp High Alarm | Read / Write |
| 80 | AV-080 | System #1 – M. Temp Low Alarm | Read / Write |
| 81 | AV-081 | System #2 – M. Temp Low Alarm | Read / Write |
| 82 | AV-082 | System #3 – M. Temp Low Alarm | Read / Write |
| 83 | AV-083 | System #4 – M. Temp Low Alarm | Read / Write |
| 84 | AV-084 | System #1 – D. Temp Setpoint | Read / Write |
| 85 | AV-085 | System #2 – D. Temp Setpoint | Read / Write |
| 86 | AV-086 | System #3 – D. Temp Setpoint | Read / Write |
| 87 | AV-087 | System #4 – D. Temp Setpoint | Read / Write |
| 88 | AV-088 | System #1 – D. Temp High Alarm | Read / Write |
| 89 | AV-089 | System #2 – D. Temp High Alarm | Read / Write |
| 90 | AV-090 | System #3 – D. Temp High Alarm | Read / Write |
| 91 | AV-091 | System #4 – D. Temp High Alarm | Read / Write |
| 92 | AV-092 | System #1 – D. Temp Low Alarm | Read / Write |
| 93 | AV-093 | System #2 – D. Temp Low Alarm | Read / Write |
| 94 | AV-094 | System #3 – D. Temp Low Alarm | Read / Write |
| 95 | AV-095 | System #4 – D. Temp Low Alarm | Read / Write |
| 96 | AV-096 | System #1 – Flow Switch Conf. | Read / Write |
| 97 | AV-097 | System #2 – Flow Switch Conf. | Read / Write |
| 98 | AV-098 | System #3 – Flow Switch Conf. | Read / Write |
| 99 | AV-099 | System #4 – Flow Switch Conf. | Read / Write |
| 100 | AV-100 | mA 1 – Output Value | Read / Write |
| 101 | AV-101 | mA 2 – Output Value | Read / Write |
| 102 | AV-102 | mA 3 – Output Value | Read / Write |
| 103 | AV-103 | mA 4 – Output Value | Read / Write |
| 104 | AV-104 | mA 5 – Output Value | Read / Write |
| 105 | AV-105 | mA 6 – Output Value | Read / Write |
| 106 | AV-106 | System #1 – Timer #1 – Run Time | Read / Write |
| 107 | AV-107 | System #1 – Timer #2 – Run Time | Read / Write |
| 108 | AV-108 | System #1 – Timer #3 – Run Time | Read / Write |
| 109 | AV-109 | System #1 – Timer #4 – Run Time | Read / Write |
| 110 | AV-110 | System #1 – Timer #5 – Run Time | Read / Write |
| 111 | AV-111 | System #2 – Timer #1 – Run Time | Read / Write |
| 112 | AV-112 | System #2 – Timer #2 – Run Time | Read / Write |
| 113 | AV-113 | System #2 – Timer #3 – Run Time | Read / Write |
| 114 | AV-114 | System #2 – Timer #4 – Run Time | Read / Write |
| 115 | AV-115 | System #2 – Timer #5 – Run Time | Read / Write |
| 116 | AV-116 | System #3 – Timer #1 – Run Time | Read / Write |
| 117 | AV-117 | System #3 – Timer #2 – Run Time | Read / Write |
| 118 | AV-118 | System #3 – Timer #3 – Run Time | Read / Write |
| 119 | AV-119 | System #3 – Timer #4 – Run Time | Read / Write |
| 120 | AV-120 | System #3 – Timer #5 – Run Time | Read / Write |
| 121 | AV-121 | System #4 – Timer #1 – Run Time | Read / Write |
| 122 | AV-122 | System #4 – Timer #2 – Run Time | Read / Write |
| 123 | AV-123 | System #4 – Timer #3 – Run Time | Read / Write |
| 124 | AV-124 | System #4 – Timer #4 – Run Time | Read / Write |
| 125 | AV-125 | System #4 – Timer #5 – Run Time | Read / Write |
| 126 | AV-126 | Read-Only Mode | Read Only |
Multi-State Value Object Instance Summary (Table 1-6)
Note #1 1=H-OFF 2=H-ON 3=OFF 4=ON
| Instance ID | Object Name | Purpose | Present Value – Access |
| 0 | MSV-000 | Relay 1 – State | Read / Write |
| 1 | MSV-001 | Relay 2 – State | Read / Write |
| 2 | MSV-002 | Relay 3 – State | Read / Write |
| 3 | MSV-003 | Relay 4 – State | Read / Write |
| 4 | MSV-004 | Relay 5 – State | Read / Write |
| 5 | MSV-005 | Relay 6 – State | Read / Write |
| 6 | MSV-006 | Relay 7 – State | Read / Write |
| 7 | MSV-007 | Relay 8 – State | Read / Write |
| 8 | MSV-008 | Relay 9 – State | Read / Write |
| 9 | MSV-009 | Relay 10 – State | Read / Write |
| 10 | MSV-010 | Relay 11 – State | Read / Write |
| 11 | MSV-011 | Relay 12 – State | Read / Write |
| 12 | MSV-012 | Relay 13 – State | Read / Write |
| 13 | MSV-013 | Relay 14 – State | Read / Write |
| 14 | MSV-014 | Relay 15 – State | Read / Write |
| 15 | MSV-015 | Relay 16 – State | Read / Write |
| 16 | MSV-016 | Relay 17 – State | Read / Write |
| 17 | MSV-017 | Relay 18 – State | Read / Write |
| 18 | MSV-018 | Relay 19 – State | Read / Write |
| 19 | MSV-019 | Relay 20 – State | Read / Write |
Get the Advantage in Water Treatment Equipment
Advantage Controls can give you the Advantage in products, knowledge and support on all of your water treatment equipment needs.
- Cooling Tower Controllers
- Boiler Blow Down Controllers
- Blow Down Valve Packages
- Solenoid Valves
- Water Meters
- Chemical Metering Pumps
- Corrosion Coupon Racks
- Chemical Solution Tanks
- Solid Feed Systems
- Feed Timers
- Filter Equipment
- Glycol Feed Systems
- Pre-Fabricated Systems

Troubleshooting
- Setup menu options not visible: The manual notes that if the BAC options are not visible, the “dual network card needs to be enabled.”
- After BACnet reset: The manual instructs that after pressing RESET and accepting with Enter, the communications card will reset after a short countdown, and then you must cycle power to the controller.
- Network not receiving traffic from MegaTron: The manual states that the Building Management System needs to be on the same subnet to properly receive traffic from the MegaTron, which may require advanced routing or advanced switching equipment programming.
- WebAdvantage connectivity requirements: For WebAdvantage, the manual states that an internet gateway with firewall and security rules in place is required (if you are using WebAdvantage service).