Keypad Functions

  • ACCUREX-RX-series-Weighing-Indicators-fig-1Off function.
  • ACCUREX-RX-series-Weighing-Indicators-fig-2On function and function selection during normal operation and configuration.
  • ACCUREX-RX-series-Weighing-Indicators-fig-3Zero display and set zero point or enter a tare value.
  • ACCUREX-RX-series-Weighing-Indicators-fig-4A weight is tare and display net weight.

Display Status

ACCUREX-RX-series-Weighing-Indicators-fig-5Mains power is applied to the indicator.
A weight has been tarred and display the net weight.
Zero display.
Weight is stable.
The display is temporarily set to high resolution.
The unit of weighing is lb.

Calibration

  • Press the ACCUREX-RX-series-Weighing-Indicators-fig-6key continuously and switch on the device (do not release the key at any time) Wait for a short beep and release suddenly.
  • Let the counting cycle continue and when finished press the ACCUREX-RX-series-Weighing-Indicators-fig-7key. ACCUREX-RX-series-Weighing-Indicators-fig-8will be displayed.
  • Press theACCUREX-RX-series-Weighing-Indicators-fig-9 key. 〖CAL 00〗 will come out.
  • Press theACCUREX-RX-series-Weighing-Indicators-fig-7 key. The unit will perform a zeroing operation and the weight to be calibrated will be displayed (default total capacity – e.g. 60.00)
  • If you want to change the calibration value, press the ACCUREX-RX-series-Weighing-Indicators-fig-4key and 0000.00 will appear.
  • PressACCUREX-RX-series-Weighing-Indicators-fig-4 until the digit to be modified flashes, then press to modify itACCUREX-RX-series-Weighing-Indicators-fig-3 to the desired value (e.g. 10k = 0010.00) Place the calibration weight on the scale.
  • Once the weight has been deposited, press theACCUREX-RX-series-Weighing-Indicators-fig-7 key and the calibration will be performed and the actual weight will appear. Calibration completed.

A/D Counts Display

  • Press【ON/*】three times, display〖-A-d-〗, press【→T←】, display〖123456〗, A/D (Digital/Analog) counts 123456, press the【ON/*】to return to weighing mode.

Select Display Mode

  • In normal weighing status, press【ON/*】for 2 seconds, unit of weighing is lb, press【ON/*】for 2 seconds, unit of weighing is kg.

Zero

  • When the weight is stable, press【→0←】, display〖 0.00〗, zero status LED is turned on. Zero range is ± 2%FS.

Tare and Remove Tare

  • Tare: When Tare status LED is off and the weight is ≥0 and stable, press【→T←】 to acquire tare and switch to net mode, the tare status LED is turned on.
  • Remove tare: When Tare status LED is on, press【→T←】 will switch to gross mode and removed tare. The tare status LED is off.

Battery Capacity

  • When after turn on indicator, display〖bt 85〗is battery capacity.

Low Battery Warning

  • When the battery is capacity less than 10% of full charge, display will flash. When the battery has no power, the indictor display〖 bAtt 〗turn off immediately.

LED Error Code

  • Display〖 OUEr〗, weight > FS + 9d, display〖 –OUEr 〗, weight < -2% FS, Display〖 Error〗, calibration error.

Gram Precision S.L. Travesía Industrial, 11 · 08907 Hospitalet de Llobregat · Barcelona (Spain) Tel. +34 902 208 000 · +34 93 300 33 32 Fax +34 93 300 66 98 comercial@gram.es www.gram-group.com

Documents / Resources

ACCUREX RX series Weighing Indicators [pdf] User Manual
RX series Weighing Indicators, RX series, Weighing Indicators, Indicators

References

Leave a comment

Your email address will not be published. Required fields are marked *