MW-logo

MW APV-16E series 16W Single Output Switching Power Supply

MW APC-12E series 12W Single Output Switching Power Supply-fig1

Features

  • Constant current design
  • Protections:Short circuit/ Over voltage
  • Fully isolated plastic case
  • Small and compact size
  • Cooling by free air convection
  • Class II power unit, no FG
  • No load power consumption <0.5W
  • IP42 design
  • Suitable for LED lighting and moving sign applications
  • 100% full load burn-in test
  • Low cost/ High reliability
  • 2 years warranty

Description

APV-16E series is one 16W AC/DC constant voltage mode single output LED power supply. It accepts input 180264VAC and provides four models with different output voltage, 5V, 12V, 15V,24V, respectively, that the small wattage LED applications employ the most frequently. Exploiting Class II design (without FG pin) and adopting the 94V-0 flame retardant plastic enclosure, APV-16E ideally fits the entry-level LED applications.

Model Encoding

MW APV-16E series 16W Single Output Switching Power Supply-F1

 

Applications

  • Suitable for LED related fixture or appliance (such as LED Decoration or Advertisement devices) (Note.8)

GTIN CODE

MW Search: https://www.meanwell.com/serviceGTIN.aspx

12W Single Output Switching Power Supply

SPECIFICATION

MODEL APV-16E-5 APV-16E-12 APV-16E-15 APV-16E-24
 

 

 

OUTPUT

DC VOLTAGE 5V 12V 15V 24V
RATED CURRENT 2.6A 1.25A 1A 0.67A
CURRENT RANGE 0 ~ 2.6A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.67A
RATED POWER 13W 15W 15W 16.08W
RIPPLE & NOISE (max.)Note.2 100mVp-p 120mVp-p 120mVp-p 150mVp-p
VOLTAGE TOLERANCE Note.3 ±5.0%
LINE REGULATION ±1.0%
LOAD REGULATION ±2.0%
SETUP, RISE TIME  Note.6 500ms, 30ms / 230VAC at full load
HOLD UP TIME (Typ.) 20ms/230VAC at full load
 

 

 

INPUT

VOLTAGE RANGE  Note.4 180 ~ 264VAC         254 ~ 370VDC
FREQUENCY RANGE 47 ~ 63Hz
POWER FACTOR (Typ.) PF>0.5/230VAC at full load
EFFICIENCY (Typ.) 75% 79% 80% 82%
AC CURRENT 0.3A/230VAC
INRUSH CURRENT(Typ.) COLD START 50A(twidth=185μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER 13 units (circuit breaker of type B) / 22 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT 0.25mA / 240VAC
 

PROTECTION

OVER LOAD Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 6.75V 13.8 ~ 16V 17.5 ~ 21V 27.6 ~ 32.4V
Protection type : Shut off o/p voltage, clamping by zener diode
 

 

ENVIRONMENT

WORKING TEMP. -30 ~ +70℃(Refer to “Derating Curve”)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
 

SAFETY & EMC

SAFETY STANDARDS EAC TP TC 004, IP42 , BS EN/EN 62368-1 approved
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC
ISOLATION RESISTANCE I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION Compliance to BS EN/EN55032,BS EN/EN61000-3-2,BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY Compliance to BS EN/EN55035,BS EN/EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), EAC TP TC 020
 

OTHERS

MTBF 6876.1K hrs min.     Telcordia SR-332 (Bellcore) ;      1055.5K hrs min.     MIL-HDBK-217F (25℃)
DIMENSION 77*40*29mm (L*W*H)
PACKING 0.1Kg; 120pcs/14Kg/1.06CUFT
NOTE 1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.

2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3.  Tolerance : includes set up tolerance, line regulation and load regulation.

4.  Derating may be needed under low input voltage. Please check the static characteristics for more details.

5.  The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

6.  Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.

7.  The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

8.  This product is not intended for LED lighting luminaire applications in the EU.(In the EU the LPF/NPF/XLG series are recommended.)

9.  For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf

※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx

Mechanical Specification

MW APC-12E series 12W Single Output Switching Power Supply-fig4

Block Diagram

MW APC-12E series 12W Single Output Switching Power Supply-fig5

Derating Curve

MW APC-12E series 12W Single Output Switching Power Supply-fig6

Static Characteristics

MW APC-12E series 12W Single Output Switching Power Supply-fig7

Documents / Resources

MW APV-16E series 16W Single Output Switching Power Supply [pdf] Instruction Manual
APV-16E series, 16W Single Output Switching Power Supply, APV-16E series 16W Single Output Switching Power Supply, Output Switching Power Supply, Power Supply

References

Leave a comment

Your email address will not be published. Required fields are marked *