LX SFP220-VS Variable Speed Swimming Pool Pump Instruction Manual

SFP220-VS Variable Speed Swimming Pool Pump

Specifications

  • Model: SFP220-VS
  • Voltage: 115/208-230 Volts
  • Frequency: 50 or 60Hz
  • Speed Range: 450 to 3450 RPM
  • Motor Type: Variable speed, high efficiency

Product Information

Pump Features:

The pump is equipped with a variable speed, high efficiency
motor that provides flexibility in terms of motor speed. Pumps are
designed to run continuously maintaining a sanitary environment at
the lowest possible speed, minimizing energy consumption while
protecting the environment.

Drive Features:

The integrated electronics interface controls the speed and the
duration of the run. The pump can operate at speeds ranging from
450 to 3450 revolutions per minute (RPM). It is designed to operate
within the voltage range of 115/280-230 volts at either 50 or 60Hz
input frequency.

Product Usage Instructions

Installation:

Location: Choose a suitable location for the
pump considering access to power source and proper ventilation.

Piping: Ensure correct piping connections
according to the installation diagram.

Fitting and Valves: Install necessary fittings
and valves for proper pump operation.

Electrical Installation: Follow wiring
instructions carefully for safe electrical installation.

Wiring Operation:

Wiring position: Position the wires securely
and follow the provided wiring diagram.

Grounding: Ensure proper grounding for safety
and efficient operation.

Bonding: Bond all metal parts to prevent
electrical shock.

Keypad Overview:

The keypad allows for easy operation and setting adjustments.
Familiarize yourself with the keypad layout before use.

FAQ

Q: What should I do if the pump is not operating
correctly?

A: Refer to the troubleshooting section in the manual to
identify and resolve common issues. If problems persist, contact
customer support for assistance.


“`

SFP220-VS

Important Warning and Safety Instructions —————————– 1~2

Overview ——————————————————————————- 3

Pump Features

3

Drive overview

3

Installation Diagram —————————————————————- 3

Installation —————————————————————————– 4

Location

4

Piping

4

Fitting and Valves

4

Electrical Installation

4

Wiring Operation ——————————————————————– 4

Wiring position

4~5

Grounding

5

Bonding

5

Link RS485 Signal Cable & First Start ———————————- 6

RS485 signal cable connection with

Pentair, Jandy and Hayward Automation System

6

Keypad Overview ——————————————————————– 7

Operation —————————————————————————— 8

Setting the System time

8

Programming an Operation Schedule

8

1. Program Speed and Running time in Auto Mode

8

2. Set priming, Quick clean & exhaust time and speed

8

3. Switch from Auto Mode to Manual Mode

8

Reset factory default setting

9

Lock / Unlock the keyboard

9

Turn off/ turn on button sound

9

Button cell replcement

9

Priming

9

Smart Life App Operation ————————————————– 10~11

Maintenance ————————————————————————- 12

Cleaning the pump strainer & skimmer basket

12

Winterizing

12

Pump care

12

Restart the pump

12

Troubleshooting ————————————————————– 13~14

Technical Data ———————————————————————- 15

Performance Curve and Installation Size ———————————- 16

To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
BEWARE OF ELECTRICAL SHOCK. In order to prevent a ground fault from occurring in this unit, a ground fault circuit interrupter (GFCl) must be installed on its supply circuit. The installer should install an appropriate GFCl and test it regularly. When you press the test button, the power supply should be interrupted, and when you press the reset button, the power should return. lf this is not the case, the GFCl is defective. lt is possible that an electric shockmay occur if the GFCl interrupts power to a pump without the test button being pressed. Unplug the pump and contact a qualified electrician to replace the GFCl. Never use a pump with a defective GFCl. Always testthe GFCl before use.
CAUTION ­ For Above Ground Pool pumps, it is for use with storable pools only. Do not use
with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.For In Ground Pool pumps, Unless otherwise noted, this pump is intended for use with permanent swimming pools and hot tubs and spas if they are appropriately marked. It should not be used for storable pools.

Pump Features:
· Energy Star 3.1, DOE, CEC, UL, CUL Certified. · Larger strainer basket with transparent pot lid for easy inspection. · Handle for easy carrying. · Super quiet operation as low as 42 decibels. · ANSI standard fittings (1.5″ OR 2″). · Quick & easy operation for In ground Self-priming pumps (SFP220-VS
& SWP390-VS) & above ground swimming pool pump (SHP130-VS & SHP130-VSC ). · Programable operation schedule to save energy consumption up to 80%. · NSF 50 Priming test for SFP220-VS, SWP390-VS.
Drive Features:
· User-friendly interface · Enclosures that are UV and rain-proof · Time schedule onboard · Priming & Quick Clean mode can be Programmed · Display and retention of pump alarms · Power input: 115/208-230V, 50 & 60Hz · Power limiting protection circuit · A 24-hour service is available. In case of power outages, the clock will be
retained · Lockout mode for the keypad

Drive Overview:
The pump is equipped with a variable speed, high efficiency motor that provides flexibility in terms of motor speed. There are settings for duration and intensity. Pumps are designed to run continuously maintaining a sanitary environment at the lowest possible speed, minimizing the consumption of energy while protecting the environment.

DANGER

Pump is rated for 115/208-230 Volts nominal, Only for pool pumps. Connecting incorrect voltage or use in

other applications may cause damage, personal injury or damage to

equipment.

The integrated electronics interface controls the speed and the duration of the run. The pumps can operate at speeds ranging from 450 to 3450 revolutions per minute (RPM). The pump is designed to operate within the voltage range of 115/280-230 volts at either 50 or 60Hz input frequency.

It is usually best to set the pump following our factory setting in order to minimize energy consumption; the fastest speed for the longest duration leads to more consumption of energy. However, the optimal settings can be influenced by a number of factors, such as the size of the pool, environmental conditions and the number of water features. Pumps can be programmed according to adapt to your specific needs.

First Start

1. Before starting the pump, make sure the pump basket and pipes are

completely filled with water, and that the water level in the basket is high.

2. Place the wet end lid in position and turn it counterclockwise until the

90°

lid’s ears are 90 degrees from the pump.

3. Check the pipe joints for leaks, then start the variable speed pool pump.

7. CAUTION ­ To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool.

Wiring Position: We recommend 12AWG Wire gauge and a regular 20A GFCI. If the 115V input trips, replace with a regular GFCI with 15A or more.
For 115V/60HZ input: Terminal L1 (Live Wire), Terminal N (Neutral Wire), Terminal G (Ground Wire). This applies to SHP130-VS & SHP130-VSC & SFP220-VS.

For 208-230V/60HZ input: Terminal L1 (Live Wire 1), Terminal L2 (Live Wire 2), Terminal G (Ground Wire). This applies to SFP220-VS & SWP390-VS.

WARNING- Do not bury cord. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment.
WARNING-To reduce the risk of electric shock, replace damaged cord immediately.
WARNING-Beware of accidental leakage, do not place the water pump in the open environment.
WARNING- To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply; provide a properly located outlet. 11.WARNING ­ Risk of Electric Shock. For Above Ground Pool pumps, Connect only to a grounding type receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of the plug or cord is needed, use only identical replacement parts.

For 208-230V/50HZ input: Terminal (Live Wire), Terminal (Neutral Wire),Terminal Wire). This applies to SFP220-VS & SWP390-VS.

(Ground

Link RS485 Signal Cable & First Start

RS485 Signal Cable Connection:
1. Please connect the signal cables as below wiring diagram. 2. At another end of the signal cable, please connect it to the communica
tion port of the pump and lock up the watertight nut to avoid humidity, Please look at the below diagram.

YeRlloSw48C5able RS485
Green Cable

Connect To Communication Port

The factory default setting code is C0003. The current

setting can receive signals from Pentair PL4/PLS4 and

Jandy’s Aqua Link automation system by connecting

the RS485 signal cable (Sold Separately). If you need to

connect to the Hayward Omni automation system, you

need to use the combination key:

, then, press

the key , the code is switched from C0003 to C0004.

By converting the baud rate, the pump can receive

signals from the Hayward Omni automatic control

system.

Connecting RS-485 cables with Jandy Automation System:

BlaRcSk 4C8a5ble RS485
Yellow Cable
GreGenNDCable

Commnication Port Connect To Communication Port

Our pump can be controlled by Hayward automation system via RS485 signal cable-3 wires (Sold separately). We need to change Baud Rate by pressing Tab & 2 together. Then, our pump can recognize Hayward’s Language. The wiring will be as belows:

GrGereeneGnCNCaDabblele YYeleloRllwoSwc4a8Cb5aleble
BBlalcaRkcSkC4Ca8b5aleble

ConCnoencnteTcot TCooCmommmununicicaatitoionnpPoorrtt

Our variable speed pool pumps are compatible with Pentair’s PL4/PLS4 control system , Jandy & Hayward Automation system via a dedicated RS485 signal cable. (The RS485 Signal Cable sold separately, not included in package)

DISCLAIMER

LX pumps are compatible with the Automation system of Pentair,Jandy & Hayward products.

Pentair, Jandy & Hayward are registered trademarks of Pentair, Jandy &

Hayward. This product is not affiliated with, manufactured,authorized, or

endorsed by Pentair, Jandy & Hayward.

3. After successfully connected, the monitor of pump will show ECON and the Communication indicator will be lighted up. Then, the pump gives the control right to Specific Automation System.

-6-

/GPM
Running Speed, Flow rate & Wattage (Press tab to show speed, flow rate & wattage when pump runing)
When the pump is running, In automatic mode or manual mode, you can set up the Quick-clean speed and Quick clean time. Press and hold the button for 3 seconds to enter the setting state, press
// set Quick-clean speed and Quick clean time. In automatic mode or manual mode. Clicking ‘Quick-clean’, a countdown will begin until the end. Press tab to show speed, flow rate & wattage when pump runing. Set the system time, self-priming speed, and self-priming time. Hold the button for 3 seconds, enter the settings state,and press Tab button to select the system time, self-priming speed, and self-priming time. Use and button to adjust setting value.

2.The factory default setting is manual mode . In automatic mode, the four speeds and times of operation will run according to the schedule below.
Note 2: The operation schedule needs to be programmed from 0:00 to 24:00 and the schedule CAN’T cross midnight. For example, if you set the schedule from 20:00 to 6:00, the pump will stop at midnight and keep a stationary state

be compatible

Switch from Auto Mode to Manual Mode:

The factory default setting is Maunal mode. First stop the pump (greenlight

off), then long press

for 3 seconds, he system will switch from

manual mode to auto mode. The on the screen changes to , and the

setup is complete.

If you need to restore automatic mode, please follow the same steps.

Set Self-priming Time and speed
Self-priming In-ground pool pump (Model:SFP220-VS & SWP390-VS). The factory default setting is run for 10 minutes at maximum speed (3450RPM). Non self-priming Above Ground Pool Pump (Model:SHP130-VS & SHP130-VSC). The factory default setting is run for 1 minute at maximum speed (3450RPM). In automatic mode or manual mode, hold the button for 3 seconds , the system time will blink. Then press button to select self-priming time , use
button to set self-priming time.

Set Speed in Manual Mode:
Hold one of the speed button for 3 seconds (1,2,3, quick clean), the speed numberw ill blink.Then, use button to increase or decrease the speed. lf no operation for 5 seconds, the speed number will stop blink and confirm the settings.

In the self-priming function , you can set the speed and time. The factory default setting is run at the maximum speed (3450RPM) and times (10 minutes ) to ensure air is discharged from the pipe.

Note: In Manual Mode This mode allows you to set a single speed at which the pump will run continuously until you decide to change the RPM or switch back to automatic mode. This mode is ideal for specific cleaning tasks or situations where aconstant speed is required.

ATTENTION

In order to protect the monitor, please keep closing the control panel cover if don’t use it.

WARNING CONTAINS BUTTON BATTERY. If swallowed, a button battery can cause severe internal burns and death in 2 hours. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children. If you think a battery might have been swallowed or placed inside any part of the body, call the National Battery Ingestion Hotline at 800-498-8666 immediately.””Ensure the battery compartme nt is securely closed after replacement.”

SMART LIFE APP OPERATION

Download Smart Life app from Google play (Android) or Apple store(ios). Open the app and log in or create an account if you are a new user.
1.Make sure pump is powered, your cell phone’s blue tooth is on and it is connected with a 2.4 Ghz wifi network. 2. Please Hold Up & Down button together for 3 seconds, the COMM light will flash for 5 minutes until the pump is found.Then, touch the”+” button to add device and it will start searching for the device.

Note 3: The key holder can share control right to other users. Please go back to Home page and touch the pen icon.
Then, you can see “Share Device” and touch it. Then,you can share your device
your device through WeChat, Messages or other apps or copy a link
to others as many as your wish.

2
1 LX PUMP 3
1

3.After searching for a while, you will find LX logo and add it. Then, the system will ask you for the hotspot wifi’s name and password.cSuggest to connect 2.4G NOT 5G signal Then, the pump is connected to your cell phone.
Note: the distance between the pump & the router should NOT be larger than 150 feet depending on the obstacles in between; otherwise, the connection fails.

Setting Status Bar

Model Number
Auto / Manual Mode Switch

1.Allows Manual/Auto Mode switching. If it turns on, the Manual/Auto Mode button will show up at right corner of home page. If it turns off, the pump only can be run under manual mode which is designed for taking orders from scenes created by Smart Life. 2.Unit of flow: LPM (Litre per minute) & GPM ( Gallon per minute) can be chose. 3.Self-Priming Time: the Self-Priming Time can be set from 0 to 10 minutes. 4.Priming Speed: The priming speed can be set between 1500 to 3450 RPM. 3450 RPM priming speed is highly recommended. 5.Quick Clean time: the value can be set from 0 to 60 minutes. 6.Quick Clean Speed: The Quick Clean speed can be set between 1500 to 3450 RPM. 3450 RPM priming speed is highly recommended. 7.Running Hours: it is an accumulated timer for counting how many hours the pump has been used. 8.Restore Factory Setting: if this button is pressed, all setting will be back to default settings.
In the Auto mode, Just touch Speed 1, or 2, or 3, then you will enter the below setting pager. You can set the flow (GPM) and Speed (RPM), and the start time & End time.

Self-Priming Countdown Timer
ON / OFF
Speed Setting Switch
Flow & Speed Setting Value

Error Code Showing Area
Flow Setting Switch
Start Time End Time
Quick Clean Setting

In the Manual Mode, just touch Speed 1, or 2, or 3, then you will enter the below setting pager. By moving the control bar, you can set flow & speed.

Note 1:If you want to create scenes supported by Smart Life, the pump has to be set under Manual mode. If the pump is under auto mode, it will run its preset schedule and will NOT take any other outside program. Note 2: Only one key Holder for one pump. If the key holder needs to be changed, please hold the Up & Down button together for 3 seconds. Then the previous key holder is removed from the system and COMM light will flash. Flow the instruction to add the new key holder.

Note:You can set Maximum flow, but in the real situation, you can’t reach the maximum flow because there are filters, elbows & other which will reduce the flow. The current flow rate will be shown at status bar.

Quick Clean: You can set the quick clean time and speed. At any time, you can press “quick clean” and the pump will star to work right away. After the job is done, the pump will resume back to the original schedule.
How to set the Language :Please press “me” Me and touch the top right corner button . Then there are 14 languages including English, Simplified Chinese, Traditional Chinese, Spanish, French, German, Portuguese, Italian, Russian, Arabic, Japanese. to be chosen from.

TROUBLESHOOTING

No. Error Codes Fault description Possible failure cause

Countermeasures

1

E001

IPM (Intelligent Power Module) failure

1. Power electronic components are damaged;
2. Interference causes Misoperation;
3. Poor ground connection

Check whether there is strong interference around; Check the ground wire; Contact the supplier;

2

E002

Output current 1.Sudden change or exceeds the limit abnormality of load;

Check the load or reduce the load sudden change

3

E006

Input voltage is too high

1. Abnormal input voltage; 2. Load disconnection.

Check the input power Check if the load is disconnected

4

E009

Input voltage is too low

1. Input voltage is low

Check input power

1. The voltage of the power

5

E011 Motor overload

is too low.

Check the voltage.

2. The motor stalls or the load Check the load.

changes suddenly.

1. Output wiring U/V/W phase

6

E013

Output phase loss

loss; 2. The three-phase load is

Check output wiring. Check the motor and cables.

seriously unbalanced.

7

E014

Controller Overheat

1. The ambient temperature is too high.
2. The control board is abnormal.

Decrease the ambient temperature. Contact suppliers and seek services.

8

E018

Faulty current sampling circuit

1. The current detectionelement is abnormal.
2. Abnormal amplifier circuit.

Contact suppliers and seek services. Contact suppliers and seek services.

9

E021

Display board EEPROM failure

1. Bad connection between the display board and the main drive board.
2. EEPROM damage.

Replace the connecting cable between the display board and the main drive board. Contact suppliers and seek

services.

10

E040

Static blockage failure

1. Motor mechanical lock-up. Check the load.

11

E048

PFC(Power Factor Correction)

1.The voltage is too low; 2. PFC circuit failure

over current

Check the voltage Contact suppliers and seek services

1.Display circuit board is

12 E095 Communication

bad connection with the

Fault

main circuit board.

1.Possible running dry;
13 E030 Dry Run Alarm 2.Misinform when stop
self-priming.

Check the wiring and connectors Contact suppliers and seek services Check whether the water is enough in the pump.
Contact supplier for help.

14

LOF

Dry Run Alarm

1.Flow rate is lower than 18GPM or 70 LPM

Check inlet & outlet valve. Check flow setting. Contact supplier for help.

E002 will automatically recover, and other fault codes will appear, the controller will stop, and it needs to be powered off and on again to restart the controller.

SYMPTOM
Pump does not run

CAUSE
No power to work

SOLUTION
Make sure wiring correct & securely connected. Check if the connectors between the controller and the wiring board are loose. Unplug and reconnect them. Check the GFCl operating properly. Check the fan of motor or impeller whether is broken.

Not setting system time

Set system time match your local time. Check the pump run on scheduled time.

Pump keeps tripping

Unstable current

Make sure the wire over 12AWG. Ensure independent GFCI 15A or above. If wiring at 115V trips, rewire it at 230V.

Pump not self-priming
normally

Blockage or leakage Low water pressure

Clean the skimmer and pump strainer basket. Make sure all valves in the system are open. Make sure the lid o-ring is clean and properly seated & the lid’s ears are 90 degrees to the pump body. Tighten all pipes and fittings/unions on the suction side of the pump.
Fill the pump with water before starting. Do not run pump dry. Refer to (page 9) priming instructions.

Air leaks causing bubbles in the pipe

Make sure the lid o-ring is clean and properly seated. Use a plastic hammer to help close the pump lid unitl the lid’s ears are 90 degrees to the pump body.
Tighten all pipes and fittings/unions on the suction side of the pump.

Pump makes nosie

Defective motor parts Debris in rear motor

Open the rear cover of the motor to check if the fan of the pump is damaged. The motor bearing is stuck or damaged. Take pictures and ask support.
Check and clean the back of motor is free of debirs or dirt.

Unstable voltage

The pump makes a screeching sound when running at high speed. Open the controller to check if the connection is loose and reconnect the plug.
Replace the entire controller.

SFP220-VS

SFP220-VS

NO. Name NO. Name NO. Name

1

Tie-in Nut 11 Guide vane assembly 22

Motor

2

Tie

12 Activities rings 23 Controller

3

O-Ring

13 lmpeller Nut 24

Washer

4 Pump casing 14

O-Ring

25 Hexagon bolt

5

Filter

15 Spring Washer 26 Plastic strips

6

O-Ring

16

Flat key

27

Base

7 8

Transparent cover 17
Gland cover of 18 transparent cover 19

Impeller Mechanical seal

28

Hexagon head boit and plain washer

Pump cover 29

O-Ring

9

O-Ring

20

Washer

30

Plug

10

O-Ring

21 Hexagon bolt

SFP220-VS

Additional Models
SHP130-VS, Relaax130-VS, SPH130-VS, ILG8PP130-VS; VSP13-Pro; LU-VS130; SFP220-VS, Relaax220-VS, SPH220-VS, ILG8PP220-VS; VSP22-Pro; LU-VS220; SWP390-VS, Relaax390-VS, SPH390-VS, ILG8PP390-VS; VSP39-Pro; LU-VS390

FCC Warnning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates, uses and can radiateradio frequency energy and, if not installed and used in accordance with the instructions, maycause harmful interference to radio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determined by turning the equipmentoff and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.

Documents / Resources

LX SFP220-VS Variable Speed Swimming Pool Pump [pdf] Instruction Manual
2BQZL-SFP220-VS, 2BQZLSFP220VS, SFP220-VS, SFP220-VS Variable Speed Swimming Pool Pump, SFP220-VS, Variable Speed Swimming Pool Pump, Swimming Pool Pump, Pool Pump, Pump

References

Leave a comment

Your email address will not be published. Required fields are marked *