LG KNMLB361A R32 Multi F Multi Position Air Handling Unit Owner’s Manual

KNMLB361A R32 Multi F Multi Position Air Handling Unit

Product Specifications

  • Nominal Cooling Capacity: 36,000 Btu/h
  • Nominal Heating Capacity: 40,000 Btu/h
  • Electrical: 208-230V / 60Hz / 1 phase, 3.4
    A
  • Piping:
    • Installed Liquid Pipe (in., O.D.): 3/8 Flare
    • Installed Vapor Pipe (in., O.D.): 5/8 Flare
    • Liquid Connection (in., O.D.): 3/8 Flare
    • Vapor Connection (in., O.D.): 5/8 Flare
    • Drain (in., O.D. / I.D.): 3/4 FPT
    • Temperature Sensor: Thermistor
  • Fan:
    • Type: Sirocco
    • Quantity: 1
    • Motor/Drive: Brushless Digitally Controlled / Direct
    • Air Flow H/M/L (CFM): 1,050 / 980 / 900
    • Minimum~Maximum External Static Pressure (in wg): 0.1~1.0
    • Fan Setting Value: N/A – Constant Flow
    • Dehumidification (pts./hr.): 7.17
  • Refrigerant Type: R32
  • Refrigerant Control: EEV

Product Usage Instructions

Installation:

Follow the installation manual provided with the unit for proper
setup, including piping and electrical connections.

Operation:

Ensure the unit is powered on and set the desired temperature
using the thermostat control feature.

Maintenance:

Regularly clean or replace air filters to maintain efficient
operation. Check for any leaks in the piping system.

Frequently Asked Questions (FAQ)

Q: Can I use this unit for both cooling and heating?

A: Yes, the unit has both cooling and heating capacities.

Q: What type of refrigerant does this unit use?

A: The unit uses R32 refrigerant.

Q: How do I control the fan speed?

A: The fan speed is controlled automatically based on the unit’s
settings and operation mode.

“`

Job Name/Location: Date: PO No.: Architect: Engr: Rep:
(Company)

For: File

Resubmit

Approval Other

GC: Mech:

(Project Manager)

KNM LB361A
R32 M ult i F M ult i-Posit ion Air Handling Unit
36,000 Bt u/ h Indoor Unit

Tag No.:

Performance:

Nominal Cooling Capacity (Btu/h) Nominal Heating Capacity (Btu/h)
Cooling Nominal Test Conditions: Indoor: 80°F DB / 67°F WB Outdoor: 95°F DB / 75°F WB

Heating Nominal Test Conditions: Indoor: 70°F DB / 60°F WB Outdoor: 47°F DB / 43°F WB

36,000 40,000

Electrical:

Power Supply (V/Hz/Ø)¹,² Rated Amps (A)

208-230 / 60 / 1 3.4

Piping:

Installed Liquid Pipe (in., O.D.) Installed Vapor Pipe (in., O.D.) Liquid Connection (in., O.D.) Vapor Connection (in., O.D.) Drain (in., O.D. / I.D.) Temperature Sensor

3/8 Flare 5/8 Flare 3/8 Flare 5/8 Flare
3/4 FPT Thermistor

Standard Features:

· Access Panel for Field Supplied Air Filter

Controls Features:
· Inverter (variable speed fan) · Hot start · Self diagnosis · Soft dry operation · Auto operation
· Auto restart
· Sleep mode

· Timer (on/off/weekly) · ESP control · R32 leak detection sensor · Integrated dry contact for 3rd party
thermostat

Optional Accessories:
Single-Port Shutoff Valve – PRHPZ010A Auxiliary Heater Kit – PRARH14 Electric Heater Kits – ANEHxx3Cx Downflow Conversion Kit – PNDFA0 Wi-Fi Module – PWFMDD200
Controller Options:
MultiSITETM CRC* Controllers Simple Remote Controllers Standard III Remote Controllers Deluxe Remote Controller Wireless Remote Controller Remote Temperature Button Sensor Dry Contacts

Entering Mixed Air: Cooling (°F WB) Heating (°F DB)

57 ~ 77 59 ~ 81

Unit Data:

Refrigerant Type Refrigerant Control
Sound Pressure (H/M/L) dB(A)³ Filter Dimensions7 (in) Net Weight (lbs.) Shipping Weight (lbs.)

R32
EEV 40 / 37 / 35 20 x 20 x 1
138.2 152.8

Fan:

Type Quantity Motor/Drive

Sirocco 1
Brushless Digitally Controlled / Direct

Air Flow H/M/L (CFM)

1,050 / 980 / 900

Minimum~Maximum External Static Pressure8 (in wg)

0.1~1.0

Fan Setting Value

N/A – Constant Flow

Dehumidification (pts./hr.)

7.17

Notes:
1. Acceptable operating voltage: 187V-253V. 2. The power wiring and the communication wiring from the outdoor unit to the indoor unit, or from the branch distribution unit to the indoor unit is field supplied and must be stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only). All wiring must comply with applicable local and national codes. a. Power wiring and communication wiring from outdoor unit to indoor unit (No. x AWG) 3 x 14 / 2 x 18. b. Power wiring and communication wiring from branch distribution unit to indoor unit (No. x AWG) 3 x 14 / 2 x 18. 3. Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745. 4. If a Third-Party Dry Contact and an LG internal heater or an LG Auxiliary Heater Kit is installed, supplemental heat capability cannot be controlled by the Third-Party Thermostat. 5. Electric heater accessory is available in 3~10kW capacities for 12/18/24/30k Multi F Multi-Position Air Handling Units. For 36k units, electric heater accessory is available in 3~15kW capacities. Refer to the Engineering Manual for details. 6. Requires an LG wall controller because Multi-Position Air Handling Units do not have infrared receiver. 7. Actual filter sizes may vary. 8. Maximum static pressure may result in reduced airflow (CFM). 9. See Engineering Manual for sensible and latent capacities. 10. The indoor unit comes with a dry helium charge. 11. Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 – 105%. 12. Must follow installation instructions in the applicable LG installation manual.

For a complete list of available accessories, contact your LG representative. For continual product development, LG reserves the right to change specifications without notice. © LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

SB_M ult iF_M P_AHU_R32_KNM LB361A_2025_01_27_174000
Page 1 of 3

Job Name/Location:
KNM LB361A
R32 M ult i F M ult i-Posit ion Air Handling Unit
36,000 Bt u/ h Indoor Unit

Tag No.: Date: PO No.:

For continual product development, LG reserves the right to change specifications without notice.

SB_M ult iF_M P_AHU_R32_KNM LB361A_2025_01_27_174000

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Page 2 of 3

Job Name/Location:
KNM LB361A
R32 M ult i F M ult i-Posit ion Air Handling Unit
36,000 Bt u/ h Indoor Unit

Tag No.: Date: PO No.:

For continual product development, LG reserves the right to change specifications without notice.

SB_M ult iF_M P_AHU_R32_KNM LB361A_2025_01_27_174000

© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com

Page 3 of 3

Documents / Resources

LG KNMLB361A R32 Multi F Multi Position Air Handling Unit [pdf] Owner's Manual
KNMLB361A, KNMLB361A R32 Multi F Multi Position Air Handling Unit, Multi R32 F Multi Position Air Handling Unit, R32 Multi Position Air Handling Unit, Position Air Handling Unit, Handling Unit

References

Leave a comment

Your email address will not be published. Required fields are marked *