FS -LOGO

FS S5440L-48M Enterprise Switch

FS-S5440L-48M-Enterprise-Switch-PRODUCT

Specifications

  • Model: S5440L-48M
  • Type: Enterprise Switch
  • Standard: SFP28

Introduction

Thank you for choosing the Enterprise Switch. This guide is designed to familiarize you with the layout of the switch and describe how to deploy it in your network

Accessories

FS-S5440L-48M-Enterprise-Switch-FIG- (2)

NOTE: The accessories may vary from the illustration, please prevail in kind..

Hardware Overview

Front Panel Ports

FS-S5440L-48M-Enterprise-Switch-FIG- (3)

Front Panel LEDs

FS-S5440L-48M-Enterprise-Switch-FIG- (4)

LEDs State Description
ID Solid Blue The ID indication function is enabled.
Off The ID indication function is disabled.
MGMT Solid Green The port is connected.
Blinking Amber The port is receiving or transmitting data.
Off The port is not connected.
 

 

SYS

Solid Green The system is running normally.
Solid Amber The system has triggered an alarm or error condition.
Off The system has no power supply, fails to operate, or is functioning abnormally.
 

ETH

Solid Green The port is linked.
Blinking Green The port is receiving or transmitting packets.
Off The port is not linked.
 

 

 

 

 

RJ45

Solid Green The port is linked at 2.5 Gbps.
Blinking Green The port is receiving or transmitting packets at 2.5 Gbps.
Solid Amber The port is linked at 100 Mbps/1 Gbps.
Blinking Amber The port is receiving or transmitting packets at 100 Mbps/1 Gbps.
Off The port is not linked.
 

 

 

QSFP+

Green The port is linked at 40 Gbps.
Blinking Green The port is receiving or transmitting packets at 40 Gbps.
Amber The port is linked at 10 Gbps.
Blinking Amber The port is receiving or transmitting packets at 10 Gbps.
Off The port is not linked.
 

 

 

SFP28

Solid Green The port is linked at 25 Gbps.
Blinking Green The port is receiving or transmitting packets at 25 Gbps.
Solid Amber The port is linked at 10 Gbps.
Blinking Amber The port is receiving or transmitting packets at 10 Gbps.
Off The port is not linked.

Installation Requirements

Before the installation, please make sure that you have prepared the following:

  • Standard-sized, 19-inch-wide rack with a minimum of 1U height available.
  • Category 5e or higher RJ45 Ethernet cables, and fiber optical cables. M6 screws and cage nuts.
  • Phillips screwdriver.
  • ESD bracelet, ESD gloves, or ESD clothing.
  • Cable ties, marker, and utility knife.

Site Environment

  • Make sure that the operating temperature is maintained within 0°C to 45°C.
  • Make sure that the operating humidity is maintained within 10% to 95%.
  • Make sure that the installation site is well-ventilated to ensure sufficient airflow around the switch.
  • Make sure that the installation site is free of dust, leaks, drips, heavy condensation, and moisture.
  • Make sure that the rack is properly grounded.
  • Avoid installing the equipment against the wall to facilitate heat dissipation and maintenance, and make sure that there is adequate space around its four sides.

Mounting the Switch

Desk Mounting

FS-S5440L-48M-Enterprise-Switch-FIG- (5)

  1. Attach four rubber pads to the switch bottom.
  2. Place the switch on a stable desk.

Rack Mounting

FS-S5440L-48M-Enterprise-Switch-FIG- (6)

  1. Secure the mounting brackets to the two sides of the switch with twelve M4 screws.
  2. Attach the switch to the rack using self-provided M6 screws and cage nuts.

FS-S5440L-48M-Enterprise-Switch-FIG- (7)

Grounding the Switch

FS-S5440L-48M-Enterprise-Switch-FIG- (8)

  1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the switch is mounted.
  2. Secure the other end of the grounding cable to the grounding point on the switch back panel with the washer and the screw.

Connecting the SFP28 Ports

FS-S5440L-48M-Enterprise-Switch-FIG- (9)

  1. Plug the compatible SFP28 transceiver into the SFP28 port.
  2. Connect a fiber optic cable to the transceiver, then connect the other end of the cable to another fiber device.

Connecting the QSFP+ Ports

FS-S5440L-48M-Enterprise-Switch-FIG- (10)

  1. Plug the compatible QSFP+ transceiver into the QSFP port.
  2. Connect a fiber optic cable to the transceiver, then connect the other end of the cable to another fiber device.

Connecting the RJ45 Ports

FS-S5440L-48M-Enterprise-Switch-FIG- (11)

  1. Connect an Ethernet cable to the RJ45 port of a computer, printer, network storage, or other network devices.
  2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.

Connecting the ETH Port

FS-S5440L-48M-Enterprise-Switch-FIG- (12)

  1. Connect one end of the supplied network cable to a computer.
  2. Connect the other end of the cable to the ETH port on the front of the switch.

Connecting the Console Port

FS-S5440L-48M-Enterprise-Switch-FIG- (13)

  1. Insert the RJ45 connector of the console cable into the console port on the front of the switch.
  2. Connect the other end of the console cable to the RS-232 serial port on the computer.

Connecting the Power

FS-S5440L-48M-Enterprise-Switch-FIG- (14)

  1. Plug the AC power cord into the power port on the back of the switch.
  2. Connect the other end of the power cord to an AC power source.

Configuring the Switch

Configuring the Switch Using the Web-Based Interface

  • Step 1: Connect the computer to any Ethernet port of the switch using the network cable.
  • Step 2: Set the IP address of the computer to 192.168.1.x (“x” is any number from 2 to 254).
  • Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password, admin/admin.
  • Step 4: Click LOGIN to open the web-based configuration page.

FS-S5440L-48M-Enterprise-Switch-FIG- (15)

Configuring the Switch Using the Console Port

  • Step 1: Connect a computer to the switch’s console port using the supplied console cable.
  • Step 2: Start the terminal simulation software, such as HyperTermina, on the computer.
  • Step 3: Set the parameters of the HyperTerminal: Baud rate to 115200, Data bits to 8,

Parity to None, and Stop bits to 1.

FS-S5440L-48M-Enterprise-Switch-FIG- (16)

  • Step 4: After setting the parameters, click Connect to enter.

Troubleshooting

Configuration Terminal Shows No Display or Garbled Text

  • Check the power supply status.
  • Check whether the console cable is undamaged and securely connected.
  • Check whether the connected console port is consistent with the console port configured in HyperTerminal.
  • Check terminal settings (baud rate to 115200, data bits to 8, no parity, stop bit to 1).

Newly-Inserted Expansion Module Fails to Power On

  • Check whether the module is properly inserted.

Optical Port Fails to Link

  • Check whether the fiber TX and RX connections are correct.
  • Check whether the interconnected optical modules use the same wavelength.
  • Check whether the actual link distance does not exceed the optical module’s maximum supported distance.
  • Check whether the port speeds match on both ends.
  • Check whether the fiber type meets the transmission requirements.
  • Check whether the port rate mode is properly configured for multi-rate ports.

If the above issues persist, please contact technical support for help.

Product Warranty

FS ensures our customers that for any damage or faulty items due to our workmanship, we will offer a free return within 30 days from the day you receive your goods. This excludes any custom-made items or tailored solutions.

FS-S5440L-48M-Enterprise-Switch-FIG- (17)Warranty: The product enjoys a 5-year limited warranty against defects in materials or workmanship. For more details about the warranty, please check

FS-S5440L-48M-Enterprise-Switch-FIG- (18)Return: If you want to return the item(s), information on how to return can be found at

Online Resources

FS-S5440L-48M-Enterprise-Switch-FIG- (19)

Download the FS APP

FS-S5440L-48M-Enterprise-Switch-FIG- (20)

FAQS

What do the different LED states indicate?

The LED states indicate various conditions such as port connection, data transmission, system status, and more. Refer to the user manual for detailed explanations of each LED state.

: Can I use any rack for mounting the switch?

It is recommended to use a standard-sized, 19-inch-wide rack with a minimum of 1U height for mounting the switch to ensure proper fit and stability.

Documents / Resources

FS S5440L-48M Enterprise Switch [pdf] User Guide
S5440L-48M, S5440L-48M Enterprise Switch, S5440L-48M, Enterprise Switch, Switch

References

Leave a comment

Your email address will not be published. Required fields are marked *