20 Gallon Fog Unit
Product Information
Specifications
- Model: FG-20N-2
- Capacity: 20 Gallons
- Maximum Air Pressure: 100 psi (6.9 bar)
Product Usage Instructions
Safety Precautions
Before operating the unit, ensure you have read and understood
all instructions in the manual. Failure to do so may result in
personal injury or death.
Personal Protective Equipment (PPE)
Always wear appropriate PPE as indicated in the Safety Data
Sheet (SDS) when using or servicing the unit. This includes
protection for eyes, skin, and lungs against drifting spray.
Chemical Solutions Handling
Read and follow all chemical safety precautions and handling
instructions provided by the manufacturer and SDS associated with
the chemical solution before using the unit.
Unit Operation
Do not operate the unit if damaged or leaking. Always
depressurize and clean the unit after each use. Never leave the
unit unattended while pressurized.
Air Pressure
Do not exceed 100 psi (6.9 bar) incoming air pressure when
operating the unit to prevent pressure buildup, explosion, or
serious injury.
Chemical Mixing
Flush the unit with fresh water thoroughly when switching
between alkaline and acid solutions to avoid chemical reactions or
hazards.
Environmental Protection
Dispose of packaging materials, old machine components, and
hazardous fluids according to local waste disposal regulations to
protect the environment.
Frequently Asked Questions (FAQ)
Q: Can I use hydrocarbons or flammable products with the
unit?
A: No, using hydrocarbons or flammable products may result in
explosions, fire, serious injury, or death. Never use them with the
unit.
Q: What should I do if the unit is damaged or leaking?
A: Do not operate the unit if it is damaged or leaking, as it
may result in exposure to chemical solutions, serious injury, or
death.
Q: Why is it important to wear personal protective equipment
(PPE) when using the unit?
A: Wearing PPE protects against burns, rashes, eye damage,
throat or lung damage, and death that may result from improper
handling of chemical solutions.
20 Gallon Fog Unit
Operation Manual FG-20N-2
READ ALL INSTRUCTIONS BEFORE USING OR SERVICING THIS UNIT. KEEP THIS MANUAL IN A LOCATION THAT IS READILY AVAILABLE TO USERS AND SERVICE TECHNICIANS.
English (Original Instructions)
Scan this code for operation manual
Safety
WARNING
PEOPLE OR OBJECTS CAN BE HURT OR DAMAGED IF THIS UNIT IS NOT USED CORRECTLY!
Failure to read all the instructions before operating the unit may result in personal injury or death from the improper use or the chemical solution. Anyone handling, operating or using the unit must read and understand the instructions in the manual. The buyer assumes all responsibility for safety and proper use in accordance with the instructions.
Using or servicing the unit without appropriate personal protective equipment (PPE) may result in serious injury such as burns, rashes, eye, throat or lung damage and death. Always wear PPE as indicated in the Safety Data Sheet (SDS) when using or servicing the unit. Protect eyes, skin, and lungs against drifting spray.
Chemical solutions may pose a health risk and death if they contact the skin or eyes, are inhaled or swallowed. Always read and follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and the SDS associated with the chemical solution before using the unit.
Pressure within the equipment may cause an unexpected release of the chemical solution and cause serious injury such as burns, rashes, eye damage, throat or lung damage and death. Always depressurize and clean the unit after each use. Never leave the unit unattended while pressurized.
Using the unit with fluid temperatures above 100°F (37.8°C) may result in scalding, burns, serious injury or death. DO NOT use a solution with a temperature above 100°F (37.8°C).
Operating the unit when damaged or leaking may result in exposure to chemical solutions, serious injury or death. Never use the unit if it is damaged or leaking.
Never point the discharge wand at yourself, another person, or any object you do not want covered in chemical.
Using incoming air pressure exceeding 100 psi (6.9 bar) may result in pressure buildup, explosion, serious injury or death. DO NOT exceed 100 psi (6.9 bar) incoming air pressure when operating the unit.
Use of hydrocarbons and flammable products may result in explosions, fire and serious injury or death. Never use hydrocarbons or flammable products with the unit.
Mixing an alkaline with an acid may result in a chemical reaction. Overheating of the mixture may cause it to splatter caustic compounds or release hazardous fumes, gas and vapors. Always flush the unit with fresh water thoroughly when switching from an alkaline to an acid or an acid to an alkaline.
Model: FG-20N-2
V20250128 · Page 2 of 8
NOTICE
Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit. Use of an air lubricator before the unit may result in diminished performance and damage to the unit. Do not use an air lubricator before the unit. Moisture in the air lines will damage the pump and diminish the pump life. The air must be filtered, clean, dry and free of moisture. If needed, install an air dryer before the unit.
PROTECT THE ENVIRONMENT
Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations
Model: FG-20N-2
V20250128 · Page 3 of 8
Product Overview
Requirements
Compressed air requirements Liquid temperature range
Chemical compatibility
50 psi (3.4 bar) with 7 CFM (198.2 l/min)
40-100°F (4.4-37.8°C)
Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product or contact our customer service department.
Specifications
Power type
Compressed air
Chemical pickup type
Draws from pre-mixed solution
Number of products unit can draw from One product
Suction line diameter
in. (9.5 mm) inside diameter
Capacity
20 gallons (75.7 liters)
Flow rate*
3.7 gal/hour at each nozzle
Pump seals
Santoprene, Viton, or Kalrez
Droplet size Coverage area** Run time from full tank**
15 microns at 50 psi
1 liter of solution will cover approximately 1000 cubic feet (up to system max of 47,320 cubic feet)
Approx. 1.5 hours
Number of nozzles
2 nozzles
Wheel type
Two 10 inch (25.4 cm) non-marking wheels.
*Dilution rates and flow rates given are based on chemical with viscosity of water and factory air pressure settings. **Area covered and run time may vary based on humidity, air flow, and product used.
Model: FG-20N-2
V20250128 · Page 4 of 8
Product Components
Get to know the FG-20N-2 components that you will need to use, adjust, or assemble.
Back plate assembly · Inside view
2
3
4
1 5
1. In-line strainer 2. Quick-change pump 3. Air regulator 4. Air pressure gauge 5. Back plate thumb nuts 6. Suction line valve
Model: FG-20N-2
6
V20250128 · Page 5 of 8
Tank Assembly
Front view
7
8
9
10
7. Fog nozzle 8. Hinged lid 9. Solution tank 10. Drain plug 11. Solution supply line 12. Air supply line 13. Air inlet valve 14. Air fitting 15. Suction line valve
Model: FG-20N-2
Back view
11
12
13 14
15
V20250128 · Page 6 of 8
Using your unit
Operating Instructions
Note: Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
1. Verify drain plug is securely closed. 2. Fill solution tank with pre-mixed solution. 3. Place the unit in the area to be fogged. 4. Ensure the suction line valve at the base of
the suction line is open to allow fluid flow. 5. Confirm air inlet valve is in the closed position. 6. Connect an air line to the air inlet fitting. 7. Open the air inlet valve to activate the unit. 8. Evacuate the area. 9. After the unit has stopped fogging, observe
all appropriate safety precautions before reentering the area. 10. Close the air inlet valve and disconnect the air line from the unit.
After Use Instructions
11. Disconnect the air line from the air fitting. 12. Open the air inlet valve to relieve all remaining
pressure from the unit. 13. Close the air inlet valve after all pressure has
been relieved. Store unit with inlet valve closed. 14. Before using the unit with another chemistry,
thoroughly flush with water.
2
7 5
6
4
Model: FG-20N-2
V20250128 · Page 7 of 8
Maintenance
WARNING
Performing any maintenance with the unit pressurized, and connected to the air supply may result in serious injury or death. Always ensure that the unit has been depressurized, and disconnected from the air supply before conducting any maintenance. Servicing or modifying this unit with parts not listed in this manual may cause the unit to operate improperly. Do not use unauthorized parts when servicing the unit.
Maintaining Your Unit
To keep your unit operating properly, periodically perform the following maintenance procedures:
· Inspect the pump for wear and leaks.
· Inspect nozzles for debris. Clean as needed.
· Inspect all hoses for leaks or excessive wear.
· Ensure all hose clamps are in good condition and properly secured.
· Check suction line and strainer for debris. Clean as needed.
· Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear.
Note: If your air source has a high moisture content, install a water separator to the air fitting on the backplate.
Servicing Your Unit
To service your unit, refer to the service manual which includes: · Troubleshooting procedures. · Detailed parts breakdowns and illustrations. · Part numbers of serviceable components and assemblies.
Scan this code for service manual
Model: FG-20N-2
V20250128 · Page 8 of 8