somfy 1870951 Data Hub V2

somfy-1870951-Data-Hub-V2-product

Specifications

  • Item #: 1870951
  • Product Name: SDN Data Hub V2
  • Cable Type: 4-Conductor 26 AWG Modular Cable RJ9 to RJ45 – 2.5 ft. (Power & Data, Grey) #9018545
  • Compatibility: Motor and Device

Product Usage Instructions

General

  • Indoor use only
  • Plenum rated
  • Uses RJ45 connectors
  • Ambient operating temperature
  • Dimensions: 4.66 in. L x 2.63 in. W x 1.33 in. H (10.16 cm L x 6.68 cm W x 3.38 cm H)
  • Patent pending

Connections & Indicators

The SDN Data Hub V2 allows for various connections between products. Follow SDN wiring standards for distance limitations.

Connection Diagram
The diagram shown below is meant for illustrative purposes to show the connections from product to product. This device could be used in configurations other than those shown below. For specification information on individual products, see related product information. Follow all SDN wiring standards for distance limitations.

Cable Pinout

  1. Data +
  2. Data –
  3. Reserved
  4. Power +
  5. Power +
  6. Reserved
  7. Ground –
  8. Ground –somfy-1870951-Data-Hub-V2-fig-1

Diagram 1
Note: Example showing the data hub and connected devices powered by bus linesomfy-1870951-Data-Hub-V2-fig-3

Diagram 2
Note: Example showing Data Hub and connected devices powered by motorsomfy-1870951-Data-Hub-V2-fig-2

Motor and Device Compatibility
The SDN Data Hub V2 is compatible with motors and devices such as RTS Receiver for SDN V2, DecoFlex SDN Keypad V2, and SDN Bus Booster.

  • Sonesse® 40 RS485 AC motors
  • Backwards compatible with all RS485 AC motors
    • Note: Use 4-Conductor 26 AWG Modular Cable RJ9 to RJ45 – 2.5 ft. (Power & Data, Grey) #9018545 for connection to any data hub
  • Decoflex SDN Keypads
    • Note: With two or more motors, two keypads can be powered
  • RTS Receiver for SDN
    • Note: With two or more motors, one RTS Receiver can be powered

Mounting Instructions
Refer to Figures 1, 2, 3a, and 3b in the user manual for detailed mounting instructions.

  1. Find a suitable place to install the data hub mounting bracket.
    • NOTE: To prevent cable damage, avoid bending the Cat-5e wires beyond a 1 inch radius.
  2. Use the two mounting screws provided to secure the mounting bracket (Figures 1 and 2).
    • NOTE: The mounting screws provided are suited for installing on sheet metal or wood. If you are mounting on another surface, please use a size 10 screw with a flat head.somfy-1870951-Data-Hub-V2-fig-4
  3. The data hub can be installed from the sides or from the front.
    • Side Installation (Figure 3a): Installing from the sides is only possible if there are no wires connected to the data hub.
      • If connecting from the left or right side, simply slide it underneath the snaps until it clicks into place.
    • Front Installation (Figure 3b): If wires are connected to the device or bus ports, angle the bottom of the data hub into the two bottom snaps and push it until it snaps into place.somfy-1870951-Data-Hub-V2-fig-5
  4. Removal
    • Pull up on the top snap and remove the data hub.
      • NOTE: Pull the top snap gently to avoid causing damage.

Troubleshooting

If the Bus Activity LED is always lit on all bus distribution devices, follow the standard process of elimination to isolate the problem device or segment.

Bus Overview

  • Check that your SDN bus line falls within these requirements:
    • The maximum wiring distance per bus power source is 2000 ft.
    • The distance between two bus distribution devices does not exceed 2000 ft.
    • One segment can support 40 bus distribution devices
  • Bus Activity LED is always lit on all bus distribution devices: Use standard process of elimination to isolate problem device/segment

Mis-wire Issues
Issues can stem from improper wiring. Before consulting the troubleshooting scenarios below, ensure that these common mis-wire mistakes have been double-checked and are not present in the installation:

  • Pinouts incorrect: Follow the T-568B Standard, refer to Cable Pinouts section
  • Inadequate wire stripping: Check that wires have been stripped to the correct length
  • Bad crimp: Check for any bad crimps
  • Faulty connector: Test by switching to a different brand of connector

General

  • End of Line LED is lit incorrectly: Check bus in and out are plugged in correctly
  • Bus Activity LED does not light up: Check previous Bus Activity LED of the previous data hub – if the lights are active, check for mis-wire issues between the two data hubs
  • Data Hub V2 restarts (cycling LEDs when activity occurs):
    • If the LEDs cycle when activity occurs, check for a damaged motor or bad motor wire (when there are two motors)
    • If the LEDs cycle even when there is no bus activity, there may be issues powering a keypad
  • Two motors plugged in, but Powered by Motors LED is not lit (motors will not jog when plugged in): Ensure power and data cables have been used and check for mis-wiring using the Sequence button
  • Motor does not jog when plugged into the Data Hub V2: Ensure power and data cables have been used and check for mis-wiring using the Sequence butto

Mis-wire Issues
If you encounter mis-wiring problems, refer to the troubleshooting section of the manual for guidance.

© Somfy Systems, Inc.
JANUARY 2024
All brands, products, and trademarks are the property of their respective owners.

FAQ

Q: What should I do if I encounter mis-wire issues?
A: If you encounter mis-wiring problems, refer to the troubleshooting section of the manual for guidance.