Use this guide to set up the Ecolink Zigbee 3.0 Contact Sensor DWZB1-ECO and check that it communicates with your system.

Add the sensor to your network
- Pull the exposed plastic tab from the sensor.
- The LED indicator will be lit for two seconds to indicate a successful booting.
- It will blink three times approximately every 30 seconds while scanning the network.
- If network is not found after 10 minutes, the sensor will go into sleep mode.
- To wake the sensor again, you need to use magnet or tamper to trigger a paring process, and then sensor will repeat steps from 3 to 4.
Place and test the sensor
- Please check that the sensor and magnet is located less than 0.25 inch from each other.
- For optimal performance, it is highly recommended to install the Door/Window sensor on the fixed frame and the magnet on the moving part of the door/window.
- Place the sensor near the top of the door that close to the opening edge of the door.
- This is the mounting location for the sensor.
- Use the provided double-sided tape on the sensor.
- Attach the sensor to the door/window frame.
- Press firmly and hold in place for a few seconds.
- Secure it with silicone if needed.
- For mounting with screws, please use the screw holes located in the battery compartment.
- Use provided double-sided tape on the magnet.
- Check that the alignment of both sensor and magnet is correct.
- The magnet aligns from the top of the sensor case.
- Spacers are used to raise the level of the magnet to be level/closer to sensor.
- Install spacers.
- The spacers are ¼” thick.
Manuals and code lookup
For a separate TV or set-top box remote, use the Manuals+ remote code finder.
References
- User Manualmanual.tools
Published: November 24, 2026