TECH Controllers PS-02 Sinum Relay Module

The PS-02 module is an electronic device equipped with 2 independent voltage-free relays enabling the user to control 2 independent devices. The PS-02 module can cooperate with monostable switches. It is designed to be mounted on a DIN rail. It communicates with the Sinum central device using radio signal.
Description
- Power supply
- Communication – a single signal indicates a radio signal
- Current status of the voltage-free output (ON/OFF)
Manual mode
In order to switch to the manual operation mode, press the manual operation button ①. The registration button ② is used to switch between the controlled outputs in the manual mode. Using the button ① (pressing it once), the user forces a change of the status (ON / OFF) – if the process has been successful, it is confirmed by a light signal from the LED labelled 1-2. When the manual mode is on, it is impossible to control the contact via the website or the application. To disable the manual operation mode, press and hold the button ① again and hold it for 1-2 seconds. Once the manual mode has been switched off, all the output status LEDs go off and resume the state set in the Sinum application.
How to register the device in the sinum system
Enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > Wireless devices > ④. Then briefly press the registration button ② on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room.
Technical data
| Technical data | |
|---|---|
| Power supply | 230V ±10% /50Hz |
| Max. power consumption | 1,5W |
| Maximum output load | 5A (AC1)* / 200W (LED) 2A / 30V (DC1)** |
| Operation temperature | 5 ÷ 50°C |
| Acceptable ambient relative humidity | <80% REL.H |
| Operation frequency | 868 MHz |
| Max. transmission power | 25 mW |
- AC1 load category: resistive or slightly inductive AC load
- DC1 load category: direct current, resistive or slightly inductive load.
Notes
- TECH Controllers is not responsible for any damages resulting from improper use of the system. The range depends on the conditions in which the device is used and the structure and materials used in the object construction. The manufacturer reserves the right to improve devices, update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
- Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children. It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.
Disposaal
The product may not be disposed of to household waste containers. The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

EU Declaration of conformity
- Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122) Hereby, we declare under our sole responsibility that the moduł PS-02 is compliant with Directive 2014/53/EU.
- Paweł Jura Janusz Master Paweł Jura Janusz Master Prezesi firmy
Wieprz, 01.06.2023

The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech-controllers.com/manuals