EBYTE E860-DTU Wireless Remote Synchronization Switch

Disclaimer
- EBYTE reserves all rights to this document and the information contained herein. Products, names, logos and designs described herein may in whole or in part be subject to intellectual property rights. Reproduction, use, modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited.
- The information contained herein is provided “as is” and EBYTE assumes no liability for the use of the information. No warranty, either express or implied, is given, including but not limited, with respect to the accuracy, correctness, reliability and fitness for a particular purpose of the information. This document may be revised by EBYTE at any time. For most recent documents, visit www.ebyte.com
Overview
Introduction

The Wireless Remote Synchronous Switch is an end-user device that uses LoRa modulation technology to enable wireless transmission of digital signals over long distances. It supports the acquisition of digital inputs (DI) and the control of relay outputs (DO). Its core functionality is to enable remote synchronous control without the need for wiring, offering high ease of use and allowing users to quickly integrate it into their own systems. The power supply voltage is 8–28 V DC.
Features
- Utilizes the latest LoRa technology (with a built-in wireless module), supporting wireless signal transmission and control;
- Supports models with 1- or 2-channel relay outputs (optional);
- Supports 1 or 2 input channels (optional), with dry contacts as the default;
- Supports a maximum transmission range of 10 km (optional);
- Supports one-to-one and one-to-many modes;
- Supports network outage recovery; if the outage duration exceeds a set threshold, the receiver’s output can be reset;
- Supports encrypted transmission to prevent interference between devices in the network;
- Multiple indicator lights display operating status;
- Pairing and real-time control via buttons—simple and fast;
- Features restart and factory reset buttons to handle various emergencies;
- Constructed with a flame-retardant plastic housing for safety and reliability;
- Power supply: DC 8–28 V;
- Multiple protection features, including reverse polarity protection, overcurrent protection, and overvoltage protection;
- Supports standard 35mm DIN rail mounting and mounting via positioning holes for convenient and efficient installation;
- Supports software watchdog for more stable and reliable device operation;
- Operating temperature: Industrial-grade range, -40 to 85 degrees Celsius;
- Ambient humidity: 5%–95% non-condensing
Technical Specifications
Specifications and Parameters
| Category | Name | Parameters |
| Power Supply | Operating Voltage | DC 8–28 V |
| Power Indicator | Blue LED indicator | |
| Wireless Parameters | Operating Frequency Band | 410.125–493.125 MHz / 850.125–930.125 MHz |
| Transmit Power | 22 dBm / 30 dBm (selectable) | |
| Receive Sensitivity | -148 dBm@2.4Kbps | |
| Transmission Range | 22 dBm: 5 km; 30 dBm: 10 km (clear, open environment; maximum power; antenna gain 5 dBi; height 2 m) | |
| Airspeed | 2.4K | |
| Antenna Options | SMA antenna connector (external thread, internal bore) |
| Response Time | Response Time | Within 300 ms |
| DI Input | DI Channels | 1/2-channel (optional) |
| Input Type | Dry contact/NPN type | |
| Input Indicator | Green LED indicator | |
| DO Output | Number of DO
Channels |
1/2 channels (optional) |
| DO Output Type | 1 DO output: Type A relay / 2 DO outputs: Type C relays | |
| DO Output Mode | Momentary mode | |
| Relay Contact
Rating |
10 A at 30 VDC, 10 A at 250 VAC | |
| Output Indication | Green LED indicator | |
| Power Consumption | Transmit Current Draw | 290mA @ DC 12V |
| Average Current Draw | 70mA @ DC 12V | |
| Current Draw of the Relay Along the Line | 15mA @ DC 12V | |
| Other | Product Dimensions |
|
| Product Weight | E860-DTU(1010-400SL22)-S:72g E860-DTU(2020-400SL22)-S:120g E860-DTU(1010-400SL30)-S:75g E860-DTU(2020-400SL30)-S:123g E860-DTU(1010-900SL22)-S:72g E860-DTU(2020-900SL22)-S:120g E860-DTU(1010-900SL30)-S:75g
E860-DTU(2020-900SL30)-S:123g |
|
| Operating | -40~+85℃、5%~95%RH(No condensation) |
Mechanical Dimension Drawings


Here, we will use the E860-DTU (2020-400SL22)-S and the E860-DTU (1010-400SL22)-S as examples.
Port Description 
| No | E860-DTU(1010-X00SLXX)-S Device Port Descriptions | E860-DTU(2020-X00SLXX)-S Device Port Descriptions |
| 1 | SMA Antenna Connector | 8–28 V DC (V-) |
| 2 | 8–28 V DC (V-) | 8–28 V DC (V+) |
| 3 | 8–28 V DC (V+) | Digital Input Common Terminal |
| 4 | Relay Output: Normally Closed Contact 1 | Digital Input Port 1 |
| 5 | Relay Output Common Terminal | Digital Input Common Terminal |
| 6 | Digital Input Common Terminal | Digital Input Port 2 |
| 7 | Digital Input Common Terminal | AWS Antenna Interface |
| 8 | STATE Button | Relay Output Normally Open Port 1 |
| 9 | Relay Output Common Terminal | |
| 10 | Relay Output Normally Closed
Terminal 1 |
|
| 11 | Relay Output Normally Open Terminal 2 | |
| 12 | Relay Output Common Terminal | |
| 13 | Relay Output Normally Open Terminal 2 |
LED Indicators and Button Descriptions
| Indicator Light | LED Indicator Light Colors | Note |
| DC | Red LED | Power indicator light: stays on when the power is on and turns off when the power is off. |
| STATE/LINK | Blue LED/Orange LED |
|
Detailed Explanation of Features
Operating Modes
This series offers three operating modes, as shown in the table below. When using this series of products, the system automatically selects the appropriate operating mode based on the user’s usage. Each time you switch to a different pairing mode, you must reset the device to factory settings before proceeding.
| One-on-one, bidirectional control | ![]() |
| One-to-Many—bidirectional control:
When any slave is activated, the master is controlled. |
![]() |
| One-to-Many—bidirectional control(Different Number of Channels) | Configuration: One master with 2 channels can be paired with two slave devices, each with 1 channel; the master’s DI1 controls the slave device’s DO1. |
One-on-One, Bidirectional Work Model
- For example, prepare two E860-DTU (1010-400SL22)-S units, two power supplies with a 12V DC output, and two antennas, then connect the power supplies as shown in the figure below,

- At this point, designate one of the devices as the host. Press and hold the STATE button for 2 seconds to enter configuration mode; the STATE indicator will flash. Next, press and hold the STATE button on the other device for 2 seconds; once the STATE indicator flashes, it indicates that the device has entered configuration mode. The two devices will then automatically pair to complete the pairing process. Now, briefly press the STATE button once to exit configuration mode. The device that entered pairing mode first is the master; its LINK and STATE lights will remain steady. After the slave is successfully paired, its LINK light will remain steady and its STATE light will flash. As shown in the figure below, 2-1 is the master and 2-2 is the slave.
Figure 3-2-2: After Successful Pairing of Host and Slave - At this point, DI1 on module 2-1 can control DO1 on module 2-2, and DI1 on module 2-2 can control DO1 on module 2-1, as shown in the figure below.

- Channel Synchronous Switch: This mode operates on the same principle and will not be demonstrated here. DI and DO can be connected to the appropriate control system according to the user’s selection for operation.
One-to-Many Bidirectional Control
- This mode supports up to 1 master and 200 slaves. When a DI signal is input to any slave, the master is controlled; the first device to enter pairing mode becomes the master. The master’s DI can control the DO of all slaves.
- Prepare two E860-DTU (2020-900SL22)-S units, two E860-DTU (2020-900SL30)-V2 units, three 12V DC power supplies, and three antennas, then connect them to power.
- Here, we will use the E860-DTU (2020-900SL22)-S as the master unit, hereinafter referred to as 2-1. The two slave units are the E860-DTU (2020-900SL30)-S and the E860-DTU (2020-900SL22)-S, referred to as 2-2 and 2-3, respectively. Press and hold the STATE button on 2-1 for 2 seconds to enter configuration mode; the STATE indicator light will flash. Next, press and hold the STATE button on 2-2 for 2 seconds; once the STATE indicator light flashes, it indicates that configuration mode has been entered. At this point, the two devices will automatically pair, completing the pairing process. Next, briefly press the STATE button on unit 2-2 to exit configuration mode. This completes the pairing between units 2-1 and 2-2. Next, put unit 2-3 into pairing mode; units 2-1 and 2-3 will then automatically pair. Afterward, briefly press the STATE button on each unit to exit pairing mode. This completes the one-to-many pairing for devices with the same channel number, where 2-1 is the master and 2-2 and 2-3 are the slaves, as shown in Figure 3-3-1 below. At this point, the STATE indicator lights on 2-2 and 2-3 will flash, indicating they are slaves, while the STATE indicator light on 2-1 will remain steady, indicating it is the master.


Figure 3-3-2: Host digital input DI1 controls the digital output DO1 of two slave devices 
One-to-Many Bidirectional Control (Different Channel Counts)
- Configuration: For example, if the master is a 2-channel synchronous switch, it can be paired with two 1-channel slaves. The DI and DO channel indicator lights correspond to different slaves; for instance, if Slave 1 has 2 channels, then the master’s DI1, DI2, DO1, and DO2 correspond to Slave 1.
Note: The total number of channels across all slaves must not exceed the number of channels on the master. - In this example, one E860-DTU (2020-400SL30)-S, referred to as 2-1, serves as the master, and two E860-DTU (1010-400SL22)-S units, referred to as 1-1, 1-2 as Slave 1 and Slave 2, respectively. After a successful connection, the master’s yellow LINK indicator will flash in a pattern of two on, one off. Two flashes of the yellow light indicate that two slaves are connected. Once the slaves are successfully connected in the correct order, the digital I/O mapping is complete. At this point, the correspondence between the master’s DI and the slave’s DO is as shown in the table below: 3.
| Host | Slave |
| DI1 on 2-1 | Slave 1: DO1 at 1-1 |
| DI2 on 2-1 | Slave 2: DO2 at 1-2 |
Pairs of digital I/O between the master and slave under various one-to-many bidirectional configurations with different numbers of channels

Revision history
| Versions | Revision Date | Revision Notes | Maintaining people |
| 1.0 | 2026-06-29 | Initial Version | ZT |
About us
- Technical support: support@cdebyte.com
- Documents and RF Setting download link::www.cdebyte.com
- Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com
- Phone: +86 028-61399028
- Web: www.cdebyte.com
- Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China
Documents / Resources
![]() | E860-DTU Wireless Remote Synchronization Switch |
References
- User Manualmanual.tools