Interface 6A110 Adaptation Mechanical Assembly

Overview
The 6A110 adaptation assembly is configured for a Comau SMART-5 NJ-60 application and includes a ground platform, adapter plate, flange robot interface, and DIN-standard fasteners. Its engineering drawing is 6A110-Adaptation-000(a) under the revision dates listed in the technical data.
Specifications
| Category | Specification | Value |
|---|---|---|
| Accuracy | Accuracy Class | 0.5 |
| Accuracy | Nonlinearity – %FS | ±0.1 |
| Accuracy | Hysteresis – %FS | ±0.1 |
| Accuracy | Nonrepeatability – %RO | ±0.5 |
| Accuracy | Creep, in 20 min – % | ±0.1 |
| Temperature | Effect on Zero – %RO/°C | ±0.01 |
| Temperature | Effect on Output – %/°C | ±0.05 |
| Temperature | Compensated Range | -10 to +70 °C (+14 to +158 °F) |
| Temperature | Operating Range | -10 to +85 °C (+14 to +185 °F) |
| Electrical | Rated Output – mV/V (Nominal) | ±0.4 |
| Electrical | Excitation Voltage – V MAX | 5 |
| Electrical | Crosstalk – % | ±1 |
| Electrical | Zero Balance – mV/V | <2 |
| Electrical | Input Resistance – Ω | 1K ±10 |
| Electrical | Output Resistance – Ω | 1K ±10 |
| Electrical | Input Resistance – Ω | 350 ±10 |
| Electrical | Output Resistance – Ω | 350 ±10 |
| Mechanical | Safe Overload – %CAP | 150 |
| Mechanical | Ultimate Overload – %RO | 300 |
Dimension
| No. | Description | Metric | U.S. |
|---|---|---|---|
| 1 | 2 × Ø6 E7 | Ø6 E7 mm | 2 × Ø0.2375/0.2370 in |
| 2 | 6 × M10 × 1.5 | M10 × 1.5 | 6 × M10 × 1.5 |
| 3 | Diameter | Ø110 mm | Ø4.3 in |
| 4 | Diameter | Ø100 mm | Ø3.9 in |
| 5 | Diameter | Ø80 mm | Ø3.1 in |
| 6 | Spigot Diameter, H8 | Ø65 H8 mm | Ø2.5609/2.5590 in |
| 7 | Angle | 60° | 60° |
| 8 | Angle | 45° | 45° |
| 9 | Dimension | 60 mm | 2.4 in |
| 10 | Dimension | 10.0 mm | 0.4 in |
| 11 | Dimension | 28.5 mm | 1.12 in |
| 12 | Overall Dimension | 120 ±1 mm | 4.7 ±0.04 in |
| 13 | Surface | Bolting Surface / Measuring Platform | Bolting Surface / Measuring Platform |
| 14 | Surface | Bolting Surface | Bolting Surface |
| 15 | Spigot | Ø65 H8 – Spigot | Ø2.5609/2.5590 – Spigot |

Features and Benefits
- 6-Axis – force and torque in all six axes
- Capacities – Force/Torque: 1kN/100Nm, 4kN/250Nm, 8kN/500Nm, 10kN/750Nm (224.8lbf/885lbf-in, 899.2lbf/2.2Klbf-in, 1.7Klbf/4.4Klbf-in, 2.2Klbf/6.6Klbf-in)
- Compact size
- Force and moment values MUST be calculated using supplied 36-term coefficient matrix
- Low crosstalk
- Temperature compensated
- Optional BX8 amplifier and software can be used for force and moment value calculation
Parts List
| Position | Qty (Crowd) | Art. No. | Designation | Drawing No. |
|---|---|---|---|---|
| 1 | 1 | 8678 8679 | 6A110 | 6A110_MP11_000(b) |
| 2 | 1 | – | Ground Platform | SO062_001(a) |
| 3 | 1 | – | Adapter Plate | SO062_002(a) |
| 4 | 1 | – | Flange Robot | – |
| 5 | 6 | 9084 | s-DIN7984-M8x18 | – |
| 6 | 6 | 9085 | s-DIN7984-M8x20 | – |
| 7 | 6 | 9086 | s-DIN7984-M10x16 | – |
| 8 | 1 | 9087 | s-DIN7979-D6-m6x24-St | – |
| 9 | 1 | 9088 | s-DIN7979-D8-m6x24-St | – |
| 10 | 2 | 9100 | s-DIN7979-D6-m6x16-St | – |
The following diagram shows the exploded view and engineering dimensions of the robotic component assembly, specifically configured for the Comau SMART-5 NJ-60 adaptation.
Technical Data & Engineering Specifications
| Component Naming: | 6A110 Adaptation Comau SMART-5 NJ-60 |
| Drawing Number: | 6A110-Adaptation-000(a) |
| Manufacturer: | Interface, Inc. Phone: 480-948-5555 www.interfaceforce.com |
| General Tolerances: | ISO 2768-mK |
| Edges & Dimensions: | DIN 6784 Inside Edges: +0.2 (edge symbol) Outer Edges: +0.2 (edge symbol) |
| Surface Finish: | DIN EN ISO 1302 (Rz16 symbol) |
| Scale: | 1:2 |
| Thread Countersinks: | DIN 76 Under 90° / Until 120° Until Thread Outside Diameter |
| Engineering Revision Date: | 20.06.17 (Edit) / 28.06.17 (Tstd.) |
| Protective Notice: | Observe the protective notice DIN 34 |
Installation / Setup
- Inspect assembly and mating components for defects or contamination.
- Verify mounting fixture matches specified dimensions and mounting points.
- Clean all bolting and locating surfaces.
- Align Ø65 H8 spigot with corresponding feature on the mating component.
- Position assembly for correct measurement orientation.
- Install M10 × 1.5 fasteners through six mounting locations; tighten per instructions.
- Ensure full seating—no gaps, rocking, or interference.
- With sensor, confirm axes/orientation match test system before loading.
How to Use
- Secure assembly to a rigid mounting structure.
- Attach test fixture/load structure to the measuring platform.
- Confirm load path is centered; avoid unintended contact/interference.
- Connect 6A110 sensor to measurement electronics as specified.
- Establish zero condition before testing.
- Apply loads within sensor’s rated capacity.
- Record and process all six channels using the 36-term coefficient matrix.
- After testing, verify unloaded condition of the system.
Maintenance and Cleaning
- Keep mounting/locating surfaces free from debris.
- Use a soft, lint-free cloth for dust/light contamination.
- Avoid abrasives on precision surfaces.
- Inspect threads for wear or contamination.
- Regularly check fasteners for tightness.
- Protect from impact, moisture, and unauthorized modification.
- Do not machine or alter precision features unless engineered/approved.
Safety Tips
- Only use with compatible 6A110 and rated hardware.
- Do not exceed rated force/torque.
- Ensure mounting structure is rigid and supports loads.
- Install all fasteners before loading; check for secure fit.
- Keep hands and objects clear during tests.
- Avoid impact loads unless the system is rated for them.
- Do not use damaged or improperly seated components.
- Verify the load path before operating.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Assembly does not seat properly | Contaminated/misaligned locating surfaces | Clean and realign spigot and mating feature |
| Holes do not align | Incorrect fixture dimensions/orientation | Verify dimensions and mounting pattern |
| Assembly moves during testing | Loose fasteners or inadequate structure | Properly secure all mounting points |
| Unstable measurements | Movement/vibration or weak mounting | Check load path and increase mounting rigidity |
| Inconsistent measurements | Fixture misalignment or off-axis loading | Realign fixture and confirm coordinate system |
| Sensor won’t return to zero | Residual load or mounting stress | Remove loads, inspect for unintended stress |
| Difficult threads | Damaged/contaminated threads | Clean threads, inspect before installing fasteners |
| Unexpected force/torque readings | Wrong calibration/coefficient matrix | Use correct calibration data and matrix |