APKLVSR TC1 Multi-Function Tester

Product Introduction
The TCI is a high—precision, multi—functional component testing &vice designed for electronic engineers and technicians to test and analyze the information and characteristic parameters of semiconductor components, such as transistors, diodes, triodes, and field—effect transistors (FETs), improving efficiency.
| 1 Lock the handle (lock/unlock) | 2 Transistor test area
(1231, 2327, 2 33) |
| 3 Zener diode test area (KAA) | 4 Display screen |
| 5 Inf rared rece iver port | 6 M.Jlti-functonbutton
(power on/test/switch Janguige) |
| 7 Charging indicator light | 8 Charging port |
Operating Instructions
- Power on: Short-press the multi—function button
- Power off:Automatic shutdown (after 30 seconds of inactivity/battery level below 3.3V)
- Switch language: Press and hold for 5 seconds to switch between Chinese and English.

Transistor Component Testing
Enter the transistor test area, press the locking handle, and then briefly press the multi—function button. The tester will automatically measure. After the test is completed, the test parameters and pin order will be displayed on the screen. (It can measure transistors, diodes, capacitors, resistors, and inductors.)
Warning: Always discharge the capacitor before connecting it to the I device; otherwise, it may be damaged before measurement.
Zener diode test
Place the component to be tested in the Zener diode test area (KAA) , press the locking handle, and then briefly press the multi—function button. The tester will automatically measure the components. After the test is completed, the test parameters and pin sequence will be displayed on the screen (only Zener diodes can be measured).
IR Infrared Decoding Test
After powering on and entering the main interface, use the infrared remote control to point at the device’s “IR” infrared test port. The device will automatically detect infrared data and display the corresponding infrared waveform (NEC protocol only).
- When a data code is received, a blue indicator light will flash in the upper right corner.
- When a duplicate data code is received, a red indicator light will flash in the upper right corner.
Calibration mode
Short—circuit interfaces 1, 2, and 3 in the transistor test area, then press and hold the multi—function button for 3 seconds to enter calibration mode (keep the Zener diode test area unconnected).
- Display “connect probes!” and keep interfaces 123 shorted;
- When “isolate probes!” is displayed, short—circuit the 123 interface to disconnect it;
- Once the progress bar finishes loading and displays”SelfTest End 3.1 3K,” the calibration is successful

Test Parameters


Troubleshooting / Product Specifications

Precautions
- After powering on, the device will self—test and display the battery level. When the battery voltage drops below 3.1 V, please charge the device promptly to prevent damage.
- It is not recommended to use the device to measure battery voltage; the battery voltage must be below 4.5V, otherwise it may damage the device.
- If the measured component parameters are outside the test range, the test results may indicate an incorrect component type.
- This product contains a lithium—ion battery; do not throw it into a fire to avoid danger.
- When using the device, avoid subjecting it to violent impacts, drops, or water exposure. If it accidentally gets wet, wait until it is completely dry before attempting to turn it on again; otherwise, internal components may be damaged.
Charge
The charging interface is a standard Type—C port. Pbase uses an external 5V/1 A power supply or the USB power adapter included in the package for charging. Charging: The red indicator light is constantly on. Fully charged: The green indicator light is constantly on.