SPECIFICATIONS

Light Source

  • 18 × 10W (Red, Green, Blue, White) LEDs
  • 25° beam angle

Features

  • Smooth RGBW color mixing
  • Includes dual bracket to hang on truss, mount on a wall, or set flat on the ground or set inside truss
  • Includes the IR remote control

Control

  • LCD Display with 4 buttons
  • 2 DMX Channel Modes: 4 & 8 Channels
  • 5 operational modes: Auto Run, Program Mode, Static Color Mode, Sound Active Mode, and DMX-512 Mode
  • Stand Alone or Primary/Secondary Configuration
  • 32 built-in Color Macros
  • Built-In Microphone for sound trigger
  • Dimmer: 0-100% Linear Dimming

Connections

  • Linkable: DMX via 3-pin XLR cable Electrical:
  • Multi-voltage operation: AC 100V-240V 50/60Hz
  • Power Draw: 180-Watts

Dimensions / Weight

  • Dimensions (L x W x H): 8.9″ x 6.9″ x 9″ (22.5×17.5x23cm)
  • Weight: 6.2 lbs./ 2.8kg.

Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.

2023 OPPSK all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. OPPSK logo and identifying product names and numbers herein are trademarks of OPPSK. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-OPPSK brands and product names are trademarks or registered trademarks of their respective companies. OPPSK and all affiliated companies hereby disclaim any liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.

OPPSK PRODUCTS CUSTOMER SUPPORT
Contact OPPSK Service for any product-related service and support needs. Also visit the website with questions, comments, or suggestions. Website: https://www.oppsk.com

Service:
Tel: +86-137-9853-9318 / Email: support@oppsk.com

Wholesale Business
Tel: +86-0755-23056465 / +86-19926401381 / ann@oppsk.com

Europe Energy Saving Notice
Energy Saving Matters (EuP 2009/125/EC) Saving electric energy is a key to helping protect the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!

GENERAL INFORMATION

INTRODUCTION
Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this device. These instructions contain important safety and use information.

UNPACKING
Every device has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton is damaged, carefully inspect the device for damage, and be sure all accessories necessary to install and operate the device have arrived intact. In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this device to your dealer without first contacting customer support. Please do not discard the shipping carton in the trash. Please recycle whenever possible.

CUSTOMER SUPPORT
Contact OPPSK Service for any product-related service and support needs. You may also contact us for any comments or suggestions.

  • OPPSK SERVICE USA – Monday – Friday 9:00 am to 6:00 pm PST
  • REPLACEMENT PARTS, please contact our customer service’s email: info@oppsk.com

IMPORTANT NOTICE!
THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT. DO NOT ATTEMPT ANY REPAIRS YOURSELF; DOING SO WILL VOID YOUR MANUFACTURER’S WARRANTY. DAMAGES RESULTING FROM MODIFICATIONS TO THIS FIXTURE AND/OR THE DISREGARD OF SAFETY INSTRUCTIONS AND GUIDELINES IN THIS MANUAL VOID THE MANUFACTURER’S WARRANTY AND ARE NOT SUBJECT TO WARRANTY CLAIMS AND/OR REPAIRS.

WARRANTY REGISTRATION

The 18LEDs RGBW par lights 2 pack carries 1 1-year limited warranty and a 30-day return policy by default. All returned service items, whether under warranty or not,  must be contacted in advance and accompanied by an order number. After OPPS agrees to your return, the order number must be clearly written on the outside of the return package, and a brief description of the problem, as well as the order number, must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice or order screenshot, and please contact OPPSK Products Service Department at support@oppsk.com / +86-137-9853-9318 in advance. All packages returned to the CA warehouse displaying an order number on the outside of the package will not be returned to the shipper and will not receive any after-sales service.

FEATURES
The 18LEDs RGBW Par Light is a compact and lightweight LED Par with 18 x 10-Watt, 4-IN-1 (RGBW) LEDs. Great LED Par for wash lighting lounges, clubs, stages, and venues. The red, green, blue, and white (GBW) LEDs offer a huge palette of colors to choose from via DMX, or set the fixture to one of the many built-in operational modes and let the Par RGBW LED paint the room with color.

INCLUDED ITEMS

  • 2 x 18LEDs RGBW Par Lights
  • 2 x Power Cables
  • 2 x Remote Controllers
  • 4 x Brackets
  • 4 x Knobs & Screws
  • 1 x User Manual

IP RATING
This device is IP20 rated. This means that the unit is protected against the intrusion of solids approximately the size of an adult finger (2.5mm) or larger, but the unit is not protected against water or liquid intrusion of any kind.

SAFETY GUIDELINES

This fixture is composed of sophisticated electronic components. To guarantee smooth operation, it is important to follow all instructions and guidelines in this manual.OPPSK is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual. Any modifications to the fixture and/or the included mounting hardware will void the original manufacturer’s warranty and increase the risk of damage and/or personal injury.

  • Protection class 1 – fixture must be properly grounded.
  • There are no user-serviceable parts inside this unit.
  • Do not attempt any repairs yourself; doing so will void your manufacturer’s warranty.
  • Damages resulting from modifications to this fixture and/or the disregard of safety instructions and guidelines in this manual void the manufacturer’s warranty and are not subject to any warranty claims and/or repairs.
  • Do not plug a fixture into a dimmer pack!
  • Never open this fixture while in use!
  • Unplug the power before servicing the fixture!
  • Never touch the fixture during operation, as it may be hot!
  • Keep flammable materials away from the fixture!
  • Never look directly into the light source!
  • Retina injury risk – may induce blindness!
  • Sensitive persons may suffer an epileptic shock!
  • inddry locationlyunly!
  • Do not expose the fixture to rain and moisture! Minimum distance to objects/surfaces is 1.6 feet (0.5 meters). The minimum distance to flammable materials from the surface is 8.5 inches (20 centimeters).
  • Do not touch the fixture housing during operation. Turn off the power and allow approximately 15 minutes for the fixture to cool down before serving.
  • Do not shake the fixture, and avoid brute force when installing and/or operating the fixture.
  • Do not operate the fixture if the power cord is frayed, crimped, damaged/or if any of the power cord connectors are damaged and do not insert into the fixture securely with ease. Never force a power cord connector into the fixture. If the power cord or any of its connectors are damaged, replace them immediately with a new one of the same power rating.
  • Do not block any air ventilation slots. All fan and air inlets must remain clean and never blocked. Allow approx. 20″ (50cm) between fixture and other devices or a wall for proper cooling.
  • When installing a fixture in a suspended environment, always use mounting hardware that is no less than M10 x 25 mm, and always install the fixture with an appropriately rated safety cable.
  • Always disconnect the fixture from the main power source before performing any type of service and/or cleaning procedure.
  • Only handle the power cord by the plug end. Never pull out the plug by tugging the wire portion of the cord.
  • During the initial operation of this fixture, a light smoke or smell may be emitted from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp, and will decrease gradually over . Consistent operational breaks will ensure the fixture will function properly for many years.
  • Only use original packaging and materials to transport the fixture in for service.

OVERVIEW

OPPSK-Par-Light-fig-1

INSTALLATION

FLAMMABLE MATERIAL WARNING
Keep fixture minimum 8.5″ (20cm) away from flammable materials and/or pyrotechnics.

ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.

MINIMUM DISTANCE TO OBJECTS/SURFACES IS 1.6 FEET (0.5 METERS).

DO NOT INSTALL THE FIXTURE IF YOU ARE NOT QUALIFIED TO DO SO!

  • Fixture MUST be installed following all local, national, and country commercial electrical and construction codes and regulations.
  • Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if the metal truss/structure or surface is properly certified to safely hold the combined weight of the fixture(s), clamps, cables, and accessories.
  • Maximum ambient operating temperature is 104°F (40°C). Do not use the fixture when the ambient temperature exceeds this value.
  • Fixture(s) should be installed outside walking paths, seating areas, or areas where unauthorized personnel might reach the fixture by hand.
  • NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
  • Overhead fixture installation must always be secured with a secondary safety attachment, such as an appropriately rated safety cable.
  • Allow approximately 15 minutes for the fixture to cool down before servicing.

RIGGING
Overhead rigging requires extensive experience, including calculating working load limits, knowledge of installation material being used, and periodic safety inspection of all installation material and the fixture, among other skills. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.

Orientation
The 18LEDs Stage Par Light can be mounted in any position; however, make sure adequate ventilation is provided around the product. OPPSK-Par-Light-fig-2

The fixture is fully operational in three different mounting positions: hanging upside-down, mounted sideways on trussing, or set on a flat level surface. Be sure this fixture is kept at least 0.2m (8in.) away from any flammable materials (decoration,n etc.). Always use an appropriately rated safety cable as a safety measure to prevent accidental damage and/or injury in the event the clamp fails. Never use the carrying handles for secondary attachment. OPPSK-Par-Light-fig-3

SAFETY CABLE:
ALWAYS ATTACH A SAFETY CABLE WHENEVER INSTALLING THIS FIXTURE IN A SUSPENDED ENVIRONMENT TO ENSURE THAT THE FIXTURE WILL NOT FALL IF THE CLAMP FAILS.

SET UP

Power Supply:
The 18LED par light supports a wide voltage range, which voltage range of 100 to 240 VAC, 50/60 Hz, no need to worry about the correct power voltage, and this unit can be plugged in anywhere.

DMX-512
DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA”OUT “XLR terminals located on all DMX fixtures.

DMX Linking:
DMX is a language allowing all makes and models of different manufacturers to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX-compliant. To ensure proper DMX data transmission, try to use the shortest cable path possible when linking several DMX fixtures. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example, a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line: at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send the data assigned to address 1 to that unit, no matter where it is located in the DMX chain.

Data Cable (DMX Cable) Requirements (For DMX Operation)
Data Cable (DMX Cable) Requirements (For DMX Operation): The 18LED par light can be controlled via DMX protocol. The 18LED par light has 2 DMX channels. Your unit and your DMX controller can accept either a standard 3-pin XLR connector for data input and data output. Be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male XLR connector at one end of the cable and a female XLR connector at the other.

CONTROL PANEL

The fixture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made.

  • MENU: Leave the current menu and return to the previous menu level.
  • UP: Scroll up in the currently displayed menu.
  • DOWN: Scroll down in the currently displayed menu.
  • ENTER: Select an option or confirm a selection. OPPSK-Par-Light-fig-4

SYSTEM MENU

Mode Programming Description
 

 

OMX Mode

d001~d512 OMX Mode: 4 CH

(Digital blinking: OMX connection complete)

 

A001~A512

OMX Mode: 8 CH

(Digital blinking: OMX connection complete)

Slave Mode A001 Automatically switches to slave mode if a

master-slave signal is detected in

OMX mode

Red r 000-255 Red 0-100%
Green g 000-255 Green 0-100%
Blue b 000-255 Blue 0-100%
White U 000-255 White 0-100%
 

Strobe

StO0~St15 Strobe Speed Adjustment
C001~C032 Color 1-32
Static Color CL01~CL32 Color 1-32
Jump CC00~CC15 Jump Speed Adjustment
Fade dE00~dE15 Fade Speed Adjustment
Pulse Cp00-Cp15 Pulse Speed Adjustment
 

Sound

SOU1-SOU3 SEN1-SEN9 3 Sound Mode,

Sound Sensitivity Adjustment

OPERATING INSTRUCTIONS

Operating Modes: The 18LEDs par light has five operating modes:

  • DMX control mode – This function will allow you to control each fixture’s traits with a standard DMX 512 controller.
  • RGBW Mode – Choose one of the 4 colors to remain static or adjust the intensity of each color to create your own custom color.
  • Sound Active Mode – The unit will react to sound, chasing through the built in programs. The sound sensitivity is adjustable.
  • Auto Run Mode – The unit will cycle through a set of preset internal programs. Color change and color fade speeds are adjustable.
  • Static Color Mode – There are 32 colors to choose from.

DMX Mode: Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs. The 18-LED par light has 2 DMX Channel modes. See the DMX Traits section of this manual for detailed information.

  1. This function will allow you to control each fixture’s traits with a standard DMX 512 controller.
  2. To run your fixture in DMX mode press the MENU button until “A-xxx” is displayed. “xxx” represents the currently selected address. Use the UP or DOWN buttons to select your desired DMX address.

DMX Connection
Set the product in DMX mode/A001 to control with a DMX controller.

  • Connect the product to a suitable power outlet.
  • Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on the produc.tOPPSK-Par-Light-fig-5

OPERATING INSTRUCTIONS

Static Color Mode

  1. Plug the fixture in and press the MENU button until “CL-xx” is displayed. “xx” is the number of currently selected color.
  2. There are 32 colors to choose from. Select your desired color by pressing the UP and DOWN buttons.

Program Mode
In this mode you can choose Hopping, Fade Changing, Pulse programs to run. The fade speed and program speed are both adjustable.

  1. Hopping: Plug the fixture in and press the MENU button until “CC-xx” is displayed. “xx” is the currently selected program speed from “00-15”.
  2. Fade: Plug the fixture in and press the MENU button until “dE-xx” is displayed. “xx” is the currently selected program speed from “00-15”.
  3. Pulse: Plug the fixture in and press the MENU button until “Cp-xx” is displayed. “xx” is the currently selected program speed from “00-15”.

Sound Active Mode
In this mode, the 18LEDs par light will react to sound and chase through the different colors.

  1. Plug the fixture in and press the MENU button until “Sou-x” is displayed. “x” is the currently selected sound mode from “1-3”, “Sou1-3” represents 3 sound modes, press the ENTER button, “SEN1-9” represents the sound sensitivity level.
  2. Use the UP and DOWN buttons to adjust the sensitivity. “1” is the lowest sensitivity, “9” is the highest.

Master-Slave Mode
In this mode, the 18LED par light allows you to link units together; one unit will act as the controlling unit, and the others will react to the controlling unit’s built-in programs. Any unit can act as a Primary or as a Secondary, but only one unit can be programmed to act as the “Master” Example: Set the slave unit to DMX mode “A001”, select the master unit and perform light control, the slave unit will detect the master-slave signal and switch to slave mode automatically, and finally the slave unit will follow the master unit. OPPSK-Par-Light-fig-6

DMX TRAITS: 4 CHANNEL MODE

CHANNEL DMXVALUE FUNCTION
1 0-255 Red 0-100%
2 0-255 Green 0-100%
3 0-255 Blue 0-100%
4 0-255 White 0-100%

DMX TRAITS: 8 CHANNEL MODE

CHANNEL DMXVALUE FUNCTION
1 0-255 All Dimmer
2 0-255 Red 0-100%
3 0-255 Green 0-100%
4 0-255 Blue0-100%
5 0-255 White 0-100%
6 0-7 No Function
8-255 Strobe Speed
 

 

 

7

0-9 No Function
10-50 15 Static Color Mode (CHB Control the color)
51-100 Jump Mode (CHB Control the speed)
101-150 Fade Mode (CHB Control the speed)
151-200 Pulse Mode (CH8 Control the speed)
201-220 Sound Mode 1: Jump
221-240 Sound Mode 2: Strobe
241-255 Sound Mode 3: Fade
8 0-255 Color (about CH7 9-50 ) Speed (about CH7 51-200 )

RF REMOTE OPERATION OPPSK-Par-Light-fig-7

Icon Button Function Display on Panel Function Description
  UP   Adjust brightness/ speed/ sensitivity
2 DOWN   Adjust brightness/ speed/ sensitivity
3 OFF OFF Turn off the light
4 ON Random Turn on the light
5 R rEd Red
6 G GrEE Green
7 B bluE Blue
8 w Uhlt White
9 STATIC COLOR rG1-3, Gb1-3, rb1-3 9 Mixed colors
10 AUTO Cp00-Cp15 Run auto mode
11 STROBE St00-St15 Strobe mode,

Press again +/- to adjust strobe speed

12 FADE dE00-dE15 Fade mode,

Press again +/- to adjust fade speed

13 JUMP CC00-CC15 Jump mode, Press again +/- to adjust jump speed
14 SOUND Sou1-Sou3,

 

SEn1-SEn9

Run 3 sound-active modes, Press again +/- to adjust sound sensitivity

DIMENSIONAL

OPPSK-Par-Light-fig-8

Documents / Resources

PDF thumbnailPar Light
User Manual · Par Light, Par, Light

References

Questions and answers

Helpful product questions tied to this manual. Each item links to the full Q&A page.

Browse all questions about this manual

Questions & Answers

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

  1. Is there a way to disable RF. Even in static color mode, an outside signal (not remote) will cause the fixture to change color

    🇺🇸 Anonymous asks Is there a way to disable RF. Even in static color mode, an outside signal (not remote) will cause the fixture to change color
    Manuals+ clarified question
    Question

    How do I disable the RF remote receiver on the OPPSK Par Light to prevent interference?

    Answer

    Based on the OPPSK Par Light User Manual, there is no documented menu setting or physical switch to disable the RF/IR receiver. The fixture is designed to remain responsive to remote signals while in standalone modes like Static Color Mode.

    To prevent interference from outside signals, you may try the following:

    • Switch to DMX Mode: If you are not using the remote, connecting the fixture to a DMX controller and setting it to a specific DMX address (e.g., d001 or A001) typically overrides remote input, as the fixture will prioritize the signal from the DMX cable.
    • Physical Obstruction: Since the manual refers to the remote as both "RF" and "IR" (Infrared) in different sections, if your model uses IR, you can try placing a small piece of black electrical tape over the IR receiver sensor (usually located near the LED face or the display) to block incoming signals.

    If the issue persists, you can contact OPPSK support at support@oppsk.com or +86-137-9853-9318 for further technical assistance regarding signal interference.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.