Bodet NTP Digital Clock

When receiving goods, please check that the item is not broken. If the product is damaged, a claim should be addressed to the shipping company.
Initial checks
- Thank you for choosing a BODET clock.
- This product has been carefully designed, adhering to ISO 9001 quality processes, to ensure your satisfaction. We recommend that you read this manual and the general safety measures and operating instructions carefully before handling the clock.
- Retain this manual for reference for the lifespan of your clock.
- The information supplied is non-binding; Bodet reserves the right to make changes to equipment, including functional, technical and aesthetic changes or changes to colours, without notice.
- Failure to observe these instructions may cause irreversible damage to the clock and invalidate the warranty.
- These instructions relate to NTP models. For other models, please refer to the corresponding instructions.
These instructions relate to the following clocks:
- Style 5: hours and minutes display. Height of digits: 5 cm.
- Style 5S (seconds): hours, minutes and seconds display. Height of digits: 5 cm.
- Style 7: hours and minutes display. Height of digits: 7 cm.
- Style 7D (date): hours, minutes, date, day and week display. Height of digits: 7 cm; height of letters: 5 cm.
- Style 7E (ellipse): hours, minutes and revolving seconds display on ellipse design. Height of digits: 7 cm; height of letters: 5 cm.
- Style 7S (seconds): hours, minutes and seconds display. Hours and minutes height of digits: 7 cm. Seconds ,height of digits: 7 cm
- Style 10: hours and minutes display. Height of digits 10 cm.
- Style 10S (seconds): hours, minutes and seconds display. Height of hours and minutes digits: 10 cm; height of seconds digits: 7 cm.
- Style 10D (date): hours, minutes, date, day and week display. Height of digits: 10 cm; height of letters: 7 cm.
- Style 10SD (seconds – date): hours, minutes, seconds, date, day and week display. Height of hours and minutes digits: 10 cm; height of seconds digits and letters: 7 cm.
Unpacking the clock
- Carefully unpack the clock and check the contents of the package. This should include:
- Style clock
- Manual
- IMPORTANT: product identification label An identification label is affixed to the back of the clock. Use the URL link shown to download these instructions.
Cleaning
- Use an anti-static product.
- Never use alcohol, acetone or other solvents, which may damage the clock’s casing or glass.
Pre-requisites
- For the commissioning of the clocks you must install “BODET Detect”. This software is available for download by clicking on the icon below.

- Note: the BODET clock must be connected to a PoE network socket via a PoE switch or a PoE injector. (802.3af, class 3: multicast, class 0: unicast).
- Bodet recommends the following devices:
- PoE injectors: Zyxel, Tp link, D-Link, HP, Cisco, Axis, ITE Power Supply, PhiHong, Abus, Globtek
- PoE switches: D-Link, HP, Planet, Zyxel, Cisco, NetGear, PhiHong
- Select a location to install the clock, preferably away from sources of electrical interference, such as transformers.
- Note: On a double-sided clock, incompatibilities may exist between the master and slave clocks if one of the clocks is version V1.1B11 (or lower) and the other is version V2.1A06 (or higher). It is recommended to set the clock with the most recent version as the master clock.
Installation
Wall mounting – Style 5-5S-7-7D-7E-7S
- The visuals below refer to the Style 5 clock. However, the installation process shown also applies to Styles 5S, 7, 7D and 7E. Refer to the Technical specifications on page 26 for clock dimensions.
- Fix the wall bracket to the wall using the 3 mm Ø screws supplied.along with the 3 wall plugs (Ø6 mm) Use a 6mm drill bit.
- Insert the RJ45 network cable:
- From above: cut through the upper part of the casing u and insert the cable at the back. .
- From behind: dedicated area v.
- Clip the electronic board into the wall bracket. Insert the lower part of the electronic board into the back of the wall bracket, then push the upper part of the board into the back of the bracket until it clicks w.
- Connect the RJ45 network cable to the electronic board connector x.
- Power is supplied by the PoE Ethernet network.
- Connect the network cable to the electronic board using a plastic tie (mounting hole provided in the electronic board).
- Connect the ribbon from the LED modules (clock casing) to the electronic board y.
- ATTENTION: To avoid damaging the product, please, watch for the orientation of the flat cable connector. For that purpose the connector is keyed (A) and marked (B).
- Attach the clock to the wall bracket by inserting the upper part of the clock into the back of the bracket in the slots provided, then press the clock in until it clicks. Secure the clock to the bracket at the bottom, using the mounting screw provided.
- Ensure that the cables are not trapped during this operation.
- The clock may be subsequently detached from the bracket by lifting the lower part of the clock outwards, then removing the upper part.
- Remove the protective film from the front and clean the clock using an anti-static cloth.
- Important: about double face installation on support bracket, refer to the manual supports, ref.: 607847 (included with the bracket).

Wall mounting – Style 10-10S-10D-10SD
- The visuals below refer to the Style 10 clock. However, the installation process shown also applies to Styles 10S, 10D and10SD. Refer to the Technical specifications on page 26 for clock dimensions.
- Fix the wall bracket to the wall using the four Ø4 mm screws supplied.along with the 4 wall plugs (Ø6 mm) Use a 6mm drill bit.
- Insert the RJ45 network cable:
- From above: cut through the casing at the top, between the two labels u.
- From behind: dedicated area v.
- From above: cut through the casing at the top, between the two labels u.
- From behind: dedicated area v.
- ATTENTION: To avoid damaging the product, please, watch for the orientation of the flat cable connector. For that purpose the connector is keyed (A) and marked (B).
- Attach the clock to the wall bracket by inserting the upper part of the clock into the back of the bracket in the slots provided, then press the clock in until it clicks. Secure the clock to the bracket at the bottom, using the mounting screw provided.
- Ensure that the cables are not trapped during this operation.
- The clock may be subsequently detached from the bracket by lifting the lower part of the clock outwards, then removing the upper part.
- Remove the protective film from the front and clean the clock using an anti-static cloth.
Important: about double face installation on support bracket, refer to the manual supports, ref.: 607847 (included with the bracket).

Recess mounting Style 5-5S-7-7D-7S-10
- Mounting without back cover
- According to the model of the clock make the cut-out following le dimensions listed in table below

- a) Insert the clock in the cut-out in order to mark the position of the mountig screws.
- b) Remove the clock and drill 4 holes Ø 6mm to insert the wall plugs.
- c) Feed the power cable and the synchronisation cable throught the cut-out
- d) Connect the clock and set the time (refer to page 13).
- e) Fix the clock to the wall with the 4 screws Ø4 mm


Mounting with back cover for recess mouting
According to the model of the clock make the cut-out following le dimensions listed in table below

- b) Remove the back cover and drill 2 holes Ø 6 mm (X ) to insert the wall plugs.for the back cover mounting
- c) Drill 4 holes Ø 10mm (Y ) to make room for the back cover clock mounting rivets.
- d) Feed the power cable, the synchronisation cable and the keypad cable throught the cut-out and cable glands of the back cover.
- e) Fix the back cover to the wall with the 2 screws Ø 4mm
- f) Connect the clock, adjust the brightness (page 7) and set the time (refer to page 10)
- g) Fix the clock to the back cover with the 4 screws Ø 4mm

Mounting – Style 7-7D-10-10S waterproof IP65
The clock is supplied wired and assembled. Before fitting it to the wall, connect the clock to the time distribution network in a dry environment.

Attach the clock to the wall using the 2 hexagon-head screws 1 (used to tighten the bracket to the wall) with a Ø4mm dowel:

Location of “S” and “+” keys
- These two keys are located on the back of the clock:
- Right side: when viewed from the back
- Left side: when viewed from the front (when being handled)
- The “S” key is above the “+” key.
- When pressed, an LED lights up to indicate the selected key. Example (Style 7D) showing the two keys pressed simultaneously

Style 5S-7S-10S – Timer mode
- The Style Timer Controller keypad operates in count or countdown modes. It has the following functions: start, stop, split time, closure of a dry contact when the count or countdown ends (stops at a pre-programmed time). The timer keypad can control up to ten Style 5S, Style 7S or Style 10S clocks. The electronic board for Style 5S, Style 7S and Style 10S clocks is fitted with a connector strip (j).
- Connect the Style Timer controller to the strip (j) using a 4-core cable (T-, T+, 0V and 15V) for the first clock. Wiring example with three Style 5S clocks:

Double-sided case:
-
- To display the counter on both sides connect the keypad on the master clock.
- To display the counter on only one side and the local time on the other side, connect the keypad on the slave clock.
- To link several Style 5S, Style 7S or Style 10S clocks to a single timer keypad, connect the T- and T+ terminals together using a 2-core cable (twin telephone cable). The first clock remains connected to the timer keypad via a 4-core cable.
- For more information, please refer to the StyleTimer Controller instructions.
Default configuration
- To restore factory settings, press the red button on the electronic board until the clock turns black. Open the clock to access this button (see Installation).
- Location of button on the electronic board (e.g. a Style 5 clock):

- The full factory configuration is as follows:
- IP configuration by DHCP (DHCP: ON)
- Time zone: EUR
- Synchronisation: Multicast
- Synchronisation address: 239.192.54.1
- These four parameters are displayed on the electronic board.
- Clock name: BODET-@MAC
- Pool period for unicast synchronisation: 15 mins.
- SNMP disabled
- Trap type: V2C
- Temperature alarm threshold: -5°C to +55°C
- Trap status issue period: 24 hrs
- No password
- Luminosity: level 3
- 12 hr/24 hr mode: 24hr
- Display of a non-significant 0: without.
- Eco mode: Nor
- ON & OFF time: 23 hrs OFF / 6 hrs ON
- On the electronic board connector:
- Green LED: network activity + power
- Yellow LED: network type (ON = 100 m, OFF = 10 m)
Basic configuration
- Setting time/date/year – all models except Style 7D-10D-10SD
- To set time, date and year, press and hold “S” for 3 seconds.

Configuration menu – all models except Style 7D-10D-10SD
Access the configuration menu by pressing and holding “S” then “+” for 3 seconds.

Setting time/date/year – Style 7D
To set time, date and year, press and hold “S” for 3 seconds.

Configuration menu – Style 7D
Access the configuration menu by pressing and holding “S” then “+” for 3 seconds

Available display languages:
French (F), English (GB), German (D), Spanish (SP), Italian (I), Portuguese (P), Greek (GR), Dutch (NL), Denmark (DK), Norway (N), Swedish (S), Finland (FI), Poland (PL), Hungarian (HG), Russian (RU), Croatian (HR), Romanian (RO), Czech (CZ), Slovenian (CL), Arabic (AR), Turkish (TR) Catalan (CA), Basque (BA).
Setting time/date/year – Style 10D-10SD
To set time, date and year, press and hold “S” for 3 seconds. The visuals below refer to the Style 10SD clock. However, the installation process shown also applies to Styles 10D because the seconds are not configurable.

Configuration menu – Style 10D-10SD
Access the configuration menu by pressing and holding “S” then “+” for 3 seconds.

Available display languages:
French (F), English (GB), German (D), Spanish (SP), Italian (I), Portuguese (P), Greek (GR), Dutch (NL), Denmark (DK), Norway (N), Swedish (S), Finland (FI), Poland (PL), Hungarian (HG), Russian (RU), Croatian (HR), Romanian (RO), Czech (CZ), Slovenian (CL), Arabic (AR), Turkish (TR) Catalan (CA), Basque (BA).
Web interface
There are two ways to access the web interface to configure the clock:
- Open a web browser and enter the IP address of the clock in the address bar.
- Run BODET Detect software and click on to open the appropriate web server for the networked clock (refer to the software instructions, ref.: 607548)
- BODET Detect software can be used to:
- Detect all clocks on the network
- Configure each clock (individually or by copying the settings for one clock to a group of clocks)
- Update the clock’s software version
- Check clock status
- Access downloaded MIB files
Home page

- The clock web server home page contains general information about the clock.
- The information is displayed as follows:
- Product: product type + SF (Single Face) + SUP (Supervised)
- Name: user-defined clock name
- Synchro: synchronisation status (“Strat 2” indicates that the clock is at the 2nd level from the synchronisation source) + IP address of the server on which the clock is synchronised.

- Local date: current date.
- Local time: current time.
Network configuration

- This page is used to configure the clock on the network. The warning indicates that the clock might lose network connectivity if the settings are incorrect.
- The following information is displayed:
- MAC Address: This is the clock’s MAC address. This address is unique to each device. This number is indicated on a label on the back of the Bodet clock.
- Name: User-defined clock name.
- Enable DHCP checkbox: If checked, the device’s network IP settings will be configured automatically.
- If this box is unchecked, the following settings are available:
- IP Address: Manually sets the device’s IP address (required).
- Subnet Mask: The subnet mask associates a clock with the local network (required).
- Gateway: The gateway can be used to connect the clock to two data networks.
- DNS Address: This can be used to associate a domain name with an IP address. This avoids having to enter an IP address in the browser as a user-defined name can be used instead. For example: www.bodet.com is easier to remember than 172.17.10.88.
saves your configuration and reboots the clock.
Time and synchronisation configuration
The Time Configuration page is divided into two parts. One is used to set the time zone, the other to set the synchronisation mode. The following information is displayed: Time Zone: drop-down menu to select the time zone (summer/winter time is automatically managed according to the time zone selected). It is also possible to set a time zone not defined by default in the drop-down menu ‘PROG’. When ‘PROG’ is selected in the drop-down menu, this function is used to define the offset from GMT: month, rank, day and fixed time for time changeovers.

- NTP Mode: Used to select one of 3 mode types:
- Unicast: In Address IP 1, enter the IP address of the NTP server. In this case, it is the clock that calls the NTP server.
- It is also possible to set up redundancy (if the first server fails to respond, the second is requested and so on). For this purpose up to 5 server addresses may be entered (IP address 1/2/3/4/5).
- The Periodicity field sets the frequency with which the clock requests the configured NTP servers.
- Multicast: In this case, the NTP server broadcasts the time on the Multicast address given to it. The Multicast address of the clients (receivers) must be the same as that on which the server broadcasts.
- By default, Bodet products transmit or receive using the Multicast address: 239.192.54.1
- The Multicast addresses are included between 224.0.0.0 and 239.255.255.255.
- By DHCP: As for Unicast mode, except the NTP server addresses are automatically retrieved via the DHCP server (option 42 enabled on the DHCP server).
- The checkbox “Continue to display” is used to define how the clock should respond if NTP synchronisation has been lost for 48 hours:
- If “Continue to display” is OFF, the clock blacks out and the colon is fixed.
- If “Continue to display” is ON, the clock continues to operate using its internal time base and the colon «:» ceases to flash.
is used to save any settings made on this page.
Parameters

- This page allows you to set the clock display on the network.
- The information displayed is described below:
- Luminosity: Used to set clock brightness between 4 levels from 1 (low) to 4 (high). Default brightness is 3.
- Mode 12H/24H: Used to display the time in 12- hour or 24-hour mode. Example: 8:00 (in 12-hour mode) or 20:00 (in 24-hour mode).
- Display format: Used to display the time, day and month with or without a non-significant 0. Example: 8:00 (time without non-significant 0) / 08:00 (time with non-significant 0).
- Eco Mode: Used to enable the clock’s energy-saving mode with brightness level selection. In Eco mode, the clock displays the flashing colon. This mode is set for a period configured below (Enable). This mode is disabled if the user opens the configuration menu (using the “S” and “+” keys) or changes the settings on the web server or if the clock is rebooted.
- Enable: Used to define the period when Eco mode is enabled. This mode is only enabled when the status changes. Example: if Eco mode is set at 8:30 for 8:00 (day D), the clock switches to this mode at 8:00 on the following day (D+1).
- Eco luminosity: Used to adjust the clock brightness in Eco mode to one of four levels. By default, the brightness in Eco mode is set to 25%.
- Alternate Display: Used to choose the information to be displayed alternately.
- Language: Only available on Style 7 Date. This parameter displays the default language of the Style 7 Date. Two drop-down menus are available to switch languages.
- Central Display: Only available on Style 7 Date. This parameter allows you to choose the information that will be displayed on the centre line. It is possible to display the alternation of week number and selected centre information.
- Temperature: Used to set the temperature offset value.
is used to save any settings made on this page
Alarm configuration

- This page is used to enable clock supervision, to define the information to be transmitted and the destination server. One or more settings can be defined and configured as alarms.
- The following information is displayed:
- Enable SNMP checkbox: enables monitoring of the clock from a SNMP manager.
- Community: A set of clocks defined by the user. All the clocks on the network must have the same Community name.
- Enable SNMP Trap: If enabled, error messages are sent to the SNMP Manager(s) automatically.
- SNMP Manager 1/2/3: IP addresses of servers receiving alerts from the clocks. SNMP Manager redundancy increases the reliability of alerts.
- Synchronisation failure: This parameter allows losses of synchronisation with the master clock (Sigma type) or the time server (Netsilon type) to be notified after an adjustable period. The default period is 48 hours. It is recommended that you set the loss-of-synchronisation period to approximately 3 times the value of the NTP synchronisation period selected, in order to avoid sending traps in a loop.
- Reboot: This setting is used to detect a clock reboot.
- Manipulation: This setting is used to trigger an alert if a setting is changed manually on the clock (using the “S” and “+” keys).
- Server access: This setting is used to trigger an alert if a user connects to the web server of the clock.
- Authentication failure: This setting is used to trigger an alert if a user sends an incorrect ID to the web server of the clock.
- Periodic Status: This setting is used to verify that the device is still working correctly (in case alerts are “lost”). This verification is carried out at a set frequency.
Information: The errors or faults reported are minor and a visit by a maintenance technician to correct the fault is not strictly necessary.
Warning: The errors or faults reported are significant and a visit by a maintenance technician to correct the fault is necessary.
Critical: The errors or faults reported are serious and an urgent visit by a maintenance technician to correct the fault is necessary.
is used to save any settings made on this page
. is used to send a trap status to all of the configured SNMP managers to ensure that supervision is configured correctly.
System

- This page is divided into four parts as follows:
- Part 1: Information panel displaying software version, time elapsed since the clock was powered on and the date of manufacture of the product (year/week).
- Part 2: A warning message to inform the user that once set, the correct password must be used to establish the connection with the web server. To save a username and password, enter the information in the fields provided for this purpose. Click to store your new ID and password.
- Part 3: A warning message to inform the user that a clock reboot will cause network connectivity to be lost when the reboot occurs. The button reboots the clock.
- Part 4: A warning message to inform the user that a reboot restoring factory settings will delete all user-defined settings and may cause the clock to lose network connectivity if there is no DHCP server on the network. The button reboots the clock, restoring factory settings.
- Adjusting the brightness
- Brightness can be adjusted when the Style clock is in normal operating mode, i.e. when it is neither in the configuration menu nor in the set time menu. The default brightness is level 3.

- Memory backup
- Style clocks have a permanent backup feature which stores all of the configuration parameters and display settings, even in the event of prolonged power failure.
- X – Technical specifications
- Synchronisation status: colon flashes if the clock is synchronised; colon steady then blackout if a clock is not synchronised.
- Power supply: PoE (Power over Ethernet).
- Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU.



Maintenance menu
To access the maintenance menu, open the configuration menu by pressing and holding “S” then “+” for 3 seconds. Release both keys, then press and hold “S”, then “+” again for 7 seconds.
Maintenance menu – all models except Style 7D-7E-10D-10SD

Maintenance menu – Style 7D-7E

Maintenance menu – Style 10D-10SD

What to do if…

Appendix

FAQs
Q: Can I use alcohol for cleaning the clock?
Q: What are the network requirements for connecting the clock?
Documents / Resources
![]() | NTP Digital Clock |
References
- European leader in time measurement and managementwww.bodet-time.com
- BODET Group: leader in time measurement and time managementwww.bodet.com
- User Manualmanual.tools