RAB MVS50 Microwave Sensor Instruction Manual

RAB MVS50 Microwave Sensor Instruction Manual

RAB MVS50 Microwave Sensor Instruction Manual

PERFORMANCE

RAB MVS50 Microwave Sensor Instruction Manual - PERFORMANCE

MVS SENSOR FACTORY SETTINGS

RAB MVS50 Microwave Sensor Instruction Manual - MVS SENSOR FACTORY SETTINGS

DIMENSIONS (UNIT: INCH)

RAB MVS50 Microwave Sensor Instruction Manual - DIMENSIONS

DETECTION COVERAGE (UNIT: FEET)

RAB MVS50 Microwave Sensor Instruction Manual - DETECTION COVERAGE

Highest mounting height is 50ft (optimal performance is 30ft)
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.

Well Detected Area
Possibly Detected Area

LUX ON-OFF

Sensor automatically turns on light when ambient brightness is lower than preset lux level. Following preconditions apply to use the Lux On-Off function: Use below settings for the Lux on-off function:

  • Stand-by period: Set to infinity (♾)
  • Stand-by dimming level set to: 10%, 20% or 30% (only)
  • Daylight threshold set to: 30lux, 50lux, 80lux or120lux, 200lux, 250lux, 300lux, 350lux, 400lux

RAB MVS50 Microwave Sensor Instruction Manual - LUX ON-OFF

  1. With daylight Lux setting selectedRAB MVS50 Microwave Sensor Instruction Manual - With daylight Lux setting selected
  2. MICROWAVE Sensor With daylight threshold disabledRAB MVS50 Microwave Sensor Instruction Manual - MICROWAVE Sensor
  3. With daylight threshold

RAB MVS50 Microwave Sensor Instruction Manual - With daylight threshold

Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.

RAB Logo© 2022 RAB LIGHTING Inc.
MVS50 – IN -0822 P-100162

Easy Answers
rablighting.com Visit our website for product info
Tech Help Line Call our experts: 888 722-1000
e-mail Answered promptly – sales@rablighting.com
Free Lighting Layouts Answered online or by request

Documents / Resources

PDF thumbnailMVS50 Microwave Sensor
Instruction Manual · MVS50 Microwave Sensor, MVS50, Microwave Sensor, Sensor
PDF thumbnailMVS50 Microwave Sensor
Owner's Manual · P-100162, MVS50, MSR1, MVS50 Microwave Sensor, Sensor, MVS50 Sensor, Microwave Sensor

References

Questions and answers

Helpful product questions tied to this manual. Each item links to the full Q&A page.

Browse all questions about this manual

Questions & Answers

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

  1. what is the pin out for the RAB MVS50 sensor. 3 pins with no instructions

    🇺🇸 Anonymous asks what is the pin out for the RAB MVS50 sensor. 3 pins with no instructions
    Manuals+ clarified question
    Question

    What is the pinout for the RAB MVS50 microwave sensor's 3-pin connector?

    Answer

    Based on the RAB MVS50 performance specifications, the sensor operates on a 10.5 - 15V DC input and provides a 0-10V DIM output. While the provided manual does not explicitly label the physical pins in a diagram, a standard 3-pin configuration for this type of sensor typically corresponds to the following functions:

    • V+ (Input): 10.5 - 15V DC Power
    • GND: Common Ground
    • DIM+ (Output): 0-10V Dimming Signal

    Because the manual does not provide a specific pin map, please verify the markings on the sensor housing or the receiving socket of your RAB fixture. If no markings are present, we recommend contacting RAB Technical Support at 888-722-1000 or emailing sales@rablighting.com to prevent damage to the sensor or the LED driver.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.