3DEVOK MT 3D Scanner
Product List
Device Introduction
Device Interaction Instructions
Trigger Button
- Power On: With the device off, press and hold the button for 2 seconds to power on. Normal Power Off: With the device on, press and hold for 5 seconds, then tap “Power Off” on the screen prompt to shut down.
- Forced Power Off: Press and hold for 12 seconds under any status to force the device off. Scan Control: Short-press the button to start or pause scanning.
- Scan Mode Switch: With blue laser scanning enabled, double-press the button to switch between cross-line, parallel-line, and single-line modes.
Screen Functions

Device Charging, Discharging, and Temperature Control Instructions
The device supports three charging methods:
- Fast Charging: Use the data cable together with a power adapter for rapid charging.
- Slow Charging: Connect the data cable to a computer Type-C port for low-power charging.
- Standard Charging: Use a dedicated battery charger to charge the battery at the rated charging speed.
Scanning Power Consumption:
The computer USB port cannot fully meet scanning power requirements. The battery will still discharge during scanning, but a USB connection can extend battery runtime compared with battery-only operation.
Battery Usage Limit:
If battery charge is lower than 30%, unstable voltage may appear. The device can only power on with scanning locked automatically. Recharge the battery to ≥30% or swap in a new battery to unlock scanning.
When the ambient temperature exceeds 40°C, the built-in overheat protection mechanism of the battery will activate automatically with two levels of response:
- Level 1 Protection (55°C): Once the battery temperature rises to 55°C, the device will display a high-temperature warning and cut off the charging circuit to stop charging automatically.
- Level 2 Protection (60°C): When the battery temperature rises to 60°C, the device will force a full shutdown to prevent damage to the battery and circuits caused by excessive heat.
Specifications
Light Source Introduction
Infrared VCSEL Mode:
Supports geometric feature alignment, texture feature alignment and hybrid alignment without the markers. It is suitable for scanning medium-sized objects such as human bodies and artistic carvings.
3 Blue Laser Modes:
- 34 Crossed Blue Laser: Features the highest number of laser lines and the fastest scanning speed, ideal for rapid scanning of medium-sized parts over 50 cm.
- 7 Parallel Blue Laser Lines: Provides finer laser lines and higher resolution, suitable for high-precision scanning of small parts and artistic carvings with intricate details.
- Single Blue Laser Lines: Designed for deep holes, blind spots, complex cavities, and other areas that are difficult to cover with cross or parallel laser modes, enabling supplementary data scanning.
Scan Mode Configuration:
- Preset modes for workpieces, art carvings and human bodies can auto-match the light source and alignment algorithm for beginner-friendly operation.
- Custom mode supports manual parameter adjustment according to actual demands.
How to Perform Your First Scan
Software Download
- Download the 3DeVOK Studio scanning software.
- You may scan the QR code to get the download link, or directly visit the PC official download page: www.3devok.com/download-center

Software Installation
Install 3DeVOK Studio following the recommended PC hardware specifications.
Note: The installer will automatically install the wireless network adapter driver during the installation process.

Device Power-On
- Install batteries as shown on the label inside the battery compartment. Press and hold the side trigger button for 2 seconds to power on.
- Follow the on-screen prompts to complete language settings and enter the connection interface.

Wireless Connection
- Plug the wireless network adapter into a USB 3.0 port on your computer, then select “Wireless” on the device screen.
- Open the 3DeVOK Studio software on your computer, click “Connect Now”, and pair with the device.

Preparations Before Scanning
Place the object on a turntable or desktop, and attach several 6 mm markers randomly around it with a spacing of 6–8 cm. Ensure the scanned object and markers remain stationary relative to each other during scanning.

First Scan Workflow
- Complete device calibration (Standard & White Balance Calibration) before scanning.
- Tap “New Scan”, follow the Beginner’s Guide to get familiar with basic operations and finish the entire process of data acquisition and post-processing. Refer to the user manual and tutorial videos for detailed instructions.

Device Power-Off
After scanning, press and hold the side trigger button for 5 seconds, then tap the “Power Off” button on the screen to power off the device.

Wired Charging
You can charge the battery installed in the battery compartment using a data cable paired with a power adapter. Alternatively, remove the battery and charge it separately with a dedicated charger.

ABOUT COMPANY
- Visit our official website for more details: www.3devok.com
- SCANTECH (Hangzhou) Co., Ltd.
- Address: No. 12, Chujiatang Road, Cangqian Subdistrict, Yuhang District, Hangzhou, Zhejiang, China
- Email: iad@3d-scantech.com
- Tel: 0571-85370380
FCC Statement
- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
- Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. Install and operate this equipment with a minimum distance of 20 cm between the radiator and your body.
Operations in the 5.15-5.25GHz band are restricted to indoor use only.
Documents / Resources
![]() | MT 3D Scanner |
References
- 3DeVOK | Professional 3D Scanner Brandwww.3devok.com
- 3DeVOK Studio Scanning Softwarewww.3devok.com
- User Manualmanual.tools