14POINT7-LOGO

14POINT7 Spartan 3 v2 Lambda Controller

14POINT7-Spartan-3-v2-Lambda-Controller-PRODUCT

Specifications

  • Product: Spartan 3 v2
  • Package Contents: 1x Spartan 3 v2, 1x USB Converter, 1x Waterproof blade fuse holder, 2x 5 Amp blade fuse

Product Usage Instructions

Exhaust Installation
Insert a 5 amp fuse into the fuse holder, cut the wire at the midpoint, and securely close the lid. Connect one end of the fuse holder to the Spartan 3 red wire and the other end to a switched 12V source, preferably the fuel pump relay.

Wiring

Wire Color Name
Red Power
Black Electronics Ground

USB Communications
The Spartan 3 comes with a USB converter for communication with a computer. The USB converter uses the FTDI chipset, which is typically preinstalled on most operating systems.

Windows 10 Serial Terminal Setup
To communicate with the Spartan 3 via serial commands on Windows 10:

  1. Ensure Electronics Ground (Black), Heater Ground (White), and Power (Red) are connected and the Spartan 3 is powered.
  2. Download and install the Termite software from https://www.compuphase.com/software_termite.htm.
  3. In the Windows search bar, type “Device Manager” and open it.
  4. Locate the Spartan 3 USB converter listed as “USB Serial Port” (e.g., COM3).
  5. In Termite, click on Settings, verify the Port is correct (e.g., COM3) and set the Baud rate to 9600.

Serial Commands

To enter serial commands:

  • Connect Electronics Ground (Black), Heater Ground (White), and Power (Red).
  • Use commands like GETHW, GETFW, SETTYPE, etc., followed by specific values as per the usage note below.

Usage Note
Refer to the provided examples to understand how to format and use the serial commands effectively based on the desired settings.

Warning

  • Do not connect or disconnect the Lambda Sensor while Spartan 3 is powered.
  • The Lambda Sensor will get very hot during normal operation, please be careful when handling it.
  • Do not install the Lambda Sensor in such a manner that the unit is powered before your engine is running. An engine start can move condensation in your exhaust system to the sensor, if the sensor is already heated this can cause thermal shock and cause the ceramic internals inside the sensor to crack and deform.
  • While the Lambda Sensor is in an active exhaust stream, it must be controlled by Spartan 3. Carbon from an active exhaust can easily build up on an unpowered sensor and foul it.
  • Lambda sensor life when used with leaded fuels is between 100-500 hrs.

14POINT7-Spartan-3-v2-Lambda-Controller-FIG-1

Package Contents

1x Spartan 3 v2, 1x USB Converter, 1x Waterproof blade fuse holder, 2x 5 Amp blade fuse

Exhaust Installation

The Lambda sensor should be installed between the 10 o’clock and the 2 o’clock position, less than 60 degrees from vertical, this will allow gravity to remove water condensation from the sensor.
For all Oxygen sensor installations, the sensor must be installed before the catalytic converter.

For normally aspirated engines the sensor should be installed about 2ft from the engine exhaust port. For Turbocharged engines the sensor should be installed after the turbocharger. For Supercharged engines the sensor should be installed 3ft from the engine exhaust port.

Fuse

Insert 5 amp fuse into fuse holder, cut wire at midpoint, and secure lid. One end of the fuse holder connects to Spartan 3 red wire the other end of the fuse holder connects to a switched 12[v] source, fuel pump relay is normally recommended.

14POINT7-Spartan-3-v2-Lambda-Controller-FIG-2

Wiring

Wire Color Name Connects to Note
Red Power Switched 12[v] Use fuse holder, 12[v] should be live only when engine is running. Fuel pump relay is the recommended source.
Black Electronics Ground Ground Ground where interfacing device is grounded
White Heater Ground Ground Ground to chassis or engine block
Green High Performance Analog

Output

Interfacing device;

ECU/Gauge/datalogger/etc…

Default output is linear output; 0[v] @ 0.68 [Lambda] Linear to 5[v] @ 1.36 [Lambda], equivalent to 10-20 [AFR] for gasoline fuel
Brown Standard Performance Analog Output Default output is heater status; 0[v] = waiting for trigger before heating sensor, 1[v] = sensor heatup started, 2[v] = sensor heatup complete and sensor heater is in closed loop control
Blue CAN High
Purple CAN Low
Orange UART TX “Rx-Orange” on USB converter
Yellow UART RX “Tx-Yellow” on USB converter
Grey UART Ground “Gnd-Grey” on USB converter

USB Communications

Spartan 3 comes with a USB converter to provide USB communications with your computer. The converter is based on the popular FTDI chipset so most operating systems already have the driver preinstalled.

Windows 10 serial terminal

Electronics Ground (Black), Heater Ground (white), and Power (Red) must be connected and Spartan 3 powered to enter serial commands.
Spartan 3 cannot be powered through USB.

The recommended serial terminal is Termite, https://www.compuphase.com/software_termite.htm, please download and install the complete setup.

14POINT7-Spartan-3-v2-Lambda-Controller-FIG-3 14POINT7-Spartan-3-v2-Lambda-Controller-FIG-4 14POINT7-Spartan-3-v2-Lambda-Controller-FIG-5 14POINT7-Spartan-3-v2-Lambda-Controller-FIG-6
In windows 10 search bar, please type “Device Manager” and open it. Spartan 3 USB converter will show up as “USB Serial Port”, in this example “COM3” is assigned to Spartan 3. In Termite, click “Settings” Make sure the Port is correct and that the

Baud rate is “9600”.

Serial Commands

Electronics Ground (Black), Heater Ground (white), and Power (Red) must be connected and Spartan 3 powered to enter serial commands. Spartan 3 cannot be powered through USB.

Serial Command Usage Note Purpose Example Factory Default
GETHW Gets Hardware Version
GETFW Gets Firmware version
SETTYPEx If x is 0 then Bosch LSU 4.9

If x is 1 then Bosch LSU ADV

Sets LSU sensor type SETTYPE1 x=0, LSU 4.9
GETTYPE Gets LSU sensor type
SETCANFORMATx x is an integer 1 to 3 character long. x=0; default

x=1; Link ECU

x=2; Adaptronic ECU x=3; Haltech ECU x=4; % Oxygen*100

x=5; Extended CAN format

SETCANFORMAT0 x=0
GETCANFORMAT Gets CAN format
SETCANIDx x is an integer 1 to 4 characters long Sets 11 bit CAN id SETCANID1024

SETCANID128

x=1024
GETCANID Gets 11 bit CAN id
SETCANBAUDx x is an integer 1 to 7 characters long Sets CAN Baud Rate SETCANBAUD1000000

will set CAN Baud rate

to 1Mbit/s

X=500000,

500kbit/s

GETCANBAUD Gets CAN Baud Rate
SETCANRx If x is 1 the resistor is enabled. If x is 0 the

resistor is disabled

Enable/Disable CAN

Termination Resistor

SETCANR1

SETCANR0

x=1, CAN term Res

Enabled

GETCANR Gets CAN Term Res State;

1=enabled, 0=disabled

SETAFRMxx.x xx.x is a decimal exactly 4 characters long

including decimal point

Sets AFR Multiplier for Torque

app

SETAFM14.7

SETAFM1.00

xx.x=14.7
GETAFRM Gets AFR Multiplier for Torque

app

SETLAMFIVEVx.xx x.xx is a decimal exactly 4 characters long including decimal point. Minimum value is 0.60, maximum value is 3.40. This value can be

higher or lower than the SETLAMZEROV value.

Sets Lambda at 5[v] for the linear output SETLAMFIVEV1.36 x.xx=1.36
GETLAMFIVEV Gets the Lambda at 5[v]
SETLAMZEROVx.xx x.xx is a decimal exactly 4 characters long including decimal point. Minimum value is 0.60, maximum value is 3.40. This value can be

higher or lower than the SETLAMFIVEV value.

Sets Lambda at 0[v] for the linear output SETLAMZEROV0.68 x.xx=0.68
GETLAMZEROV Gets Lambda at 0[v]
SETPERFx If x is 0 then standard performance of 20ms. If x is 1 then high performance of 10ms. If x is 2

then optimize for lean operation.

SETPERF1 x=1, high performance
GETPERFx Gets performance
SETSLOWHEATx If x is 0 then sensor is heated at normal rate during initial power up.

If x is 1 then sensor is heated at 1/3 the normal rate during initial power up.

If x is 2 then wait, a max of 10 min, for MS3 CAN RPM signal before heating.

If x is 3 then wait, a max of 10 min, for exhaust gas to heat sensor to 350C before heating.

Requires Firmware 1.05 and above

SETSLOWHEAT1 x=0, normal sensor heatup rate
GETSLOWHEAT Gets slowheat setting
MEMRESET Reset to factory settings.
SETLINOUTx.xxx Where x.xxx is a decimal exactly 5 characters long including decimal point, greater than 0.000 and less than 5.000. Linear Output will resume

normal operation on reboot.

Allows the user to set the High Perf Linear Output to a specific voltage SETLINOUT2.500
DOCAL Pull sensor out of the exhaust. Power on wideband controller with sensor connected for about 5 minutes then issue the DOCAL command. Do Free Air Calibration and display the value. A perfect sensor will have a value of 1.00. Recommended for clone

sensors only.

GETCAL Requires Firmware 1.04 and above Gets Free Air Calibration value
RESETCAL Requires Firmware 1.04 and above Resets Free Air Calibration

value to 1.00

SETCANDRx x is an integer 1 to 4 characters long Requires Firmware 1.04 and above Sets CAN Data Rate in hz For optimal performance, CAN Data

Rate should be 200hz

x=50
GETCANDR Requires Firmware 1.04 and above Gets CAN Data Rate
SETNBMODEx If x is 0 then Standard Performance Analog Output is Simulated Narrowband.

If x is 2 then Standard Performance Analog

Output is Heater Status

Selects the function of the Standard Performance Analog Output between Simulated

Narrowband and Heater Status

SETNBMODE0 x=2, Heater Status
GETNBMODE Gets Standard Performance

Analog Output mode

SETNBSWLAMx.xxx x.xxx is a decimal exactly 5 characters long including decimal point. Requires Firmware

1.08 and above

Sets the Simulated Narrowband Switch Point in Lambda SETNBSWLAM1.005 x.xxx=1.000
GETNBSWLAM Gets the Simulated Narrowband

switch point in Lambda

*All commands are in ASCII, case does not matter, spaces do not matter.

CAN Bus Protocol Default Format (Lambda)

For %O2 CAN Format please see “Spartan 3 and Spartan 3 Lite for Lean Burn and Oxygen Metering Applications.pdf” Spartan 3’s CAN Bus operates with 11 bit addressing.

  • Default CAN Baud rate is 500kbit/s
  • Default CAN Termination resistor is enabled, this can be changed by sending “SETCANRx” serial command.
  • Default CAN Id is 1024, this can be changed by sending “SETCANIDx” serial command.
  • Data Length (DLC) is 4.
  • Default Data Rate is 50 hz, data is sent every 20[ms], this can be changed by sending “SETCANDRx” serial command. Big-endian for all data
  • Data[0] = Lambda x1000 High Byte
  • Data[1] = Lambda x1000 Low Byte
  • Data[2] = LSU_Temp/10
    Data[3] = Status
  • Lambda = (Data[0]<<8 + Data[1])/1000
  • Sensor Temperature [C] = Data[2]*10

Status

Status Value (decimal) Meaning
0 Reserved
1 Waiting for trigger before heating up
2 Sensor is heating up
3 Sensor in normal operation
4+ Reserved

Supported CAN Formats

CAN Format Name CAN Format Serial

Command

CAN Id Serial

Command

CAN BAUD Rate Serial

Command

Note
Link ECU CAN Format SETCANFORMAT1 SETCANID950 SETCANBAUD1000000 Read “Link G4+ ECU CAN Bus Configuration

for Spartan 3.pdf”

Adaptronic ECU CAN

Format

SETCANFORMAT2 SETCANID1024

(Default from factory)

SETCANBAUD1000000
MegaSquirt 3 ECU

CAN Format

SETCANFORMAT0

(Default from factory)

SETCANID1024

(Default from factory)

SETCANBAUD500000

(Default from factory)

Read “Interfacing Spartan 3 to MegaSquirt

3.pdf”

Haltech ECU CAN

Format

SETCANFORMAT3 Not required SETCANBAUD1000000 Spartan 3 Emulates Haltech WBC1

wideband controller

YourDyno Dyno

Controller CAN Format

SETCANFORMAT0

(Default from factory)

SETCANID1024

(Default from factory)

SETCANBAUD1000000
MaxxECU SETCANFORMAT0

(Default from factory)

SETCANID1024

(Default from factory)

SETCANBAUD500000

(Default from factory)

Read “Interfacing Spartan 3 to

MaxxECU.pdf”

Extended CAN Format SETCANFORMAT5 Read “Spartan 3 Extend CAN Format.pdf”

Requires Firmware 1.08 and above.

CAN Termination Resistor:
Suppose we call the ECU; Master, and devices that send/receive data to/from the ECU we call; Slave (Spartan 3, digital dashboard, EGT controller, etc…). In most applications there is one Master (ECU) and one or more Slaves that all share the same CAN Bus. If Spartan 3 is the only Slave on the CAN Bus then the CAN Termination Resistor on Spartan 3 should-be enabled using the serial command “SETCANR1”. By default the CAN Termination Resistor on Spartan 3 is enabled. If There are multiple Slaves, the Slave that is farthest from the Master (based on wire length) should have the CAN Termination Resistor enabled, all other Slaves should have their CAN Termination Resistor
disabled/disconnected. In practice; it often does not matter if the CAN Termination Resistors are properly set, but for highest reliability the CAN Termination Resistors should be properly set.

Bootloader
When Spartan 3 is powered up without the LSU Heater Ground, white wire, connected it will enter bootloader mode. Powering up Spartan 3 with the Heater Ground connected will not trigger the bootloader and Spartan 3 will work as normal.

Warranty

14Point7 warrants Spartan 3 to be free from defects for 2 years.

Disclaimer
14Point7 is liable for damages only up to the purchase price of its products. 14Point7 products should not be used on public roads.

FAQ

What is included in the Spartan 3 v2 package?

The package includes the Spartan 3 v2 unit, a USB converter, a waterproof blade fuse holder, and two 5 Amp blade fuses.

How do I set up USB communications with Spartan 3?

Simply connect the USB converter to your computer. Most operating systems already have the necessary drivers preinstalled for the FTDI chipset used in the converter.

Can I power the Spartan 3 through USB?

No, the Spartan 3 must be powered separately using a switched 12V source.

Documents / Resources

14POINT7 Spartan 3 v2 Lambda Controller [pdf] User Manual
Spartan 3 v2 Lambda Controller, Spartan 3 v2, Lambda Controller, Controller

References