ZYLUX - logo

2PCB-0002135 TX 2PCB-0002136 RX
DDaattaa SShheeeett
Module name:IA9QH5 5G_MODULE_FPC Module
Wireless Module
Model Number: ZY- IA9QH5
TX P/N: 2PCB-0002135
RX P/N: 2PCB-0002136
Version 1
September. 8, 2022

Features

  • 5.2GHz/5.8GHz ISM Band
  • GFSK modulation
  • Low BOM cost
  • Long distance > 30m (Line of sight)
  • Support 1-1 duplex mode or 1-N broadcasting mode
  • Digital I2S audio interface
  • Support no audio detection function
  • Antenna diversity
  • Short delay time variation
  • Audio format 16/24bit , 32/44.1/48K/96KHz sampling rate
  • Robust Packet error correction
  • Low power consumption
  • No RF induced audio noise
  • Audio latency time < 20ms
    (Programmable according customized spec.)

Application

  • Wireless HTiB Rear Speaker
  • Wireless Outdoor Speaker
  • Wireless TV theater
  • Wireless Audio Sender
  • Wireless Headphone
  • Wireless Stereo Ear Microphone

RF Specification

ItemMinTypMaxUnitNote
Channel Range51605245MHz
-20dB bandwidth2.5MHz2M Mode
RF Output Power12dBm
Sensitivity-91dBmThe smaller, the better

Table 1 5.2GHz RF Specification

ItemMinTypMaxUnitNote
Channel Range57355875MHz
-20dB bandwidth2.5MHz2M Mode
RF Output Power8dBm
Sensitivity-89─-dBmThe smaller, the better

Table 2 5.8GHz RF Specification

Electrical Specification

ItemMinTypMaxUnitNote
Power Supply Voltage3.03.33.6V
Operating Temperature02555
2.1CH Audio Mode
Consumption Current (TX_MODE)210mARF Power :11dBm No GPIO driving
Consumption Current (RX_MODE)103mA
0.1CH Audio Mode
Consumption Current (TX_MODE)132mARF Power :11dBm No GPIO driving
Consumption Current (RX_MODE)91mA

Table 3 

Item
SymbolParameterMinTypMaxUnitConditions
VIHInput High Threshold2.03.33VLDO_OUT=3V
VILInput Low Threshold-0.30.8VLDO_OUT=3V
VOHOutput High Threshold2.4VLDO_OUT=3V
VOLOutput Low Threshold0.4VLDO_OUT=3V

Table 5 

ZYLUX IA9QH5 5G FPC Module -

RC circuit delay time constant online calculator

ZYLUX IA9QH5 5G FPC Module - online

Mechanical Specification

ZYLUX IA9QH5 5G FPC Module - Mechanical Specification

Fig 5.1 5G_MODULE_FPC Module TX with shielding caseTX Button View Top View

ZYLUX IA9QH5 5G FPC Module - Mechanical Specification1

Fig 5.2 5G_MODULE_FPC Module

  • Dimension:46 * 25 * 1 mm
  • PCB 4 Layers
    Mechanical Drawing:

ZYLUX IA9QH5 5G FPC Module - Mechanical Drawing

Fig 5.3 Mechanical Drawing of 5G_MODULE_FPC Module with shielding case

Block Diagram

ZYLUX IA9QH5 5G FPC Module - Block Diagram

Fig 6.1 Block Diagram of IA9QH5 5G_MODULE_FPC Module

Interface

ZYLUX IA9QH5 5G FPC Module - Interface

Fig 7.1 Pin sequence of 5G_MODULE_FPC Module

PinNameI/OTX Function DefineRX Function Define
1VCCIOPDC 3.0 ~ 3.6V INDC 3.0 ~ 3.6V IN
2VCCIOPDC 3.0 ~ 3.6V INDC 3.0 ~ 3.6V IN
3DGNDPDigital GNDDigital GND
4GPIO 14I/OGPIOGPIO
5GPIO 17I/OGPIOAMP RESET(L Act)
6GPIO 16I/OGPIOGPIO
7GPIO 30I/OGPIOGPIO
8GPIO 21I/OGPIOGPIO
9SPB_I2S_DATAI/OSPB I2S audio DataSPB I2S audio Data
10SPA_I2S_DATAI/OI2S DATA 0SYNC LED
11SPA_I2S_LRCKI/OSPA I2S audio LRCKSPA I2S audio LRCK
12SPA_I2S_BCKI/OSPA I2S audio BCKSPA I2S audio BCK
13DGNDPDigital GNDDigital GND
14SPB_I2S_MCLKI/OSPB I2S audio MCLKSPB I2S audio MCLK
15SPB_I2S_LRCKI/OSPB I2S audio LRCKSPB I2S audio LRCK
16SPB_I2S_BCKI/OSPB I2S audio BCKSPB I2S audio BCK
17GPIO 13I/OGPIOGPIO
18GPIO 32I/OGPIOGPIO
19I2C_CLK_MI/OGPIOI2C Master/Slave clock signal , must be connected to VCC via a pull high resistor
20I2C_DATA_MI/OGPIOI2C Master/Slave data signal , must be connected to VCC via a pull high resistor
21I2C_CLK_SI/OI2C Master/Slave clock signal , must be connected to VCC via a pull high resistorGPIO
22I2C_DATA_SI/OI2C Master/Slave data signal , must be connected to VCC via a pull high resistorGPIO
23GPIO15I/OGPIOGPIO
24GPIO0I/OGPIOGPIO

Table 6 IO Function Define

Design Reference

ZYLUX IA9QH5 5G FPC Module - Design Reference

Fig 8.1 Design Circuit

I2S Interface

I² S interface is supported by pin Sound Port A&B (SPA&SPB). Sound Port A (SPA), including SPA0, SPA1, SPA2 and SPA3, are defined as I2S_MCLK, BCK, LRCK, and I2S_DATA respectively. Sound Port B (SPB), including SPB0, SPB1, SPB2, and SPB3, are also defined as I2S_MCLK, BCK, LRCK, and I2S_DATA respectively.
IA9QH5 I2S audio interface can work for master and slave mode.
In master mode, IA9QH5 generate I2S_MCLK/LRCK/BCK for external audio codec. In slave mode, IA9QH5 accept external LRCK/BCK signal. IA9QH5 will synchronize with external audio clock. Mono channel data can feed through left channel (Lch) pr right channel (Rch) as Figure 10.1

ZYLUX IA9QH5 5G FPC Module - Signal

I² S timing chart is shown Figure 10.2 and Table 9

ZYLUX IA9QH5 5G FPC Module - timing chart

SymbolParameterMinTypMaxUnit
tBLRBCK rising to LRCK edge60ns
tLRBLRCK edge to BCK rise60ns
tSDSSDATA setup time60ns
tSDHSDATA hold time60ns

Table 7
Audio output clock jitter is shown Table 10

SymbolParameterMinTypMaxUnitConditions
△I2S_MCLKLocking rangevs nominal I2S_MCLK frequency-800+800ppm256Fs

Table 8 Audio Output clock Jitter

DC Power Supply

10.1 Power-On Timing
On Board Flash power on timing is shown Figure 11.1 and Table 11

ZYLUX IA9QH5 5G FPC Module - Timing

SymbolParameterMinMaxUnit
tVSLVCC(min) To CS# Low10us
tPUWTime Delay From VCC(min) To Write Instruction110ms
VWIWrite Inhibit Voltage VCC(min)13.V

Table 9

10.2 DC Power
Recommend system DC power supply for IA9QH5 5G_MODULE_FPC Module as below :

ZYLUX IA9QH5 5G FPC Module - DC Power

Long power supply lines on the PCB should be avoided. VCC connections and VCC bypass capacitors must be connected as close as possible to 5G_MODULE_FPC module. Power supply ripple of module side must be below 150mVpp to ensure RF normal operation.
LDO Spec.:

⇒High PSRR Low Dropout Voltage Linear Regulators
⇒ Iout ≧ 500mA
⇒ PSRR ≧ 65dB

Antenna Application

1.1 Suggested Clear Area
The recommended antenna clearance for embedded PCB antennas are shown below. Note that this clearance should be maintained when mounting the module on a motherboard.

ZYLUX IA9QH5 5G FPC Module - Antenna Clearance

Do not place any copper, metal or even PCB in the area marked with cross lines.
Unit : mm

11.2 Antenna Pattern

  1. Port 1
    ZYLUX IA9QH5 5G FPC Module - Antenna Pattern
  2. Port 2
    ZYLUX IA9QH5 5G FPC Module - Antenna Pattern1

11.3 ANTENNA EFFICIENCY & PEAK GAIN

Frequency(GHz)Efficiency(%)(1/2)Peak Gain(dBi)(1/2)
516070.34/64.674.2/4.97
524566.12/68.713.79/5.38
573564.21/86.424.35/5.20
584058.96/78.103.73/4.22

Label

ZYLUX IA9QH5 5G FPC Module - Label

Regulatory approvals – FCC/IC

FCC and ISED certification
Label Information
The ZY-IA9QH5 module has been certified by the requirements set by the US Federal Communications Commission (Part 15) and Industry Canada (RSS-Gen, Issue 2, June 2006 and RSS-210e) for certification as modular intentional radiators. The certification identification numbers are as follows: FCC ID: XN6-IA9QH5V1
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/ TV technician for help.

CAUTION:
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment.
RF exposure warning
This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Innovation, Science and Economic Development Canada’s Notices
This device complies with Innovation, Science and Economic Development Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
Radio Frequency (RF) Exposure Information
The radiated output power of the Wireless Device is below the Innovation, Science and Economic Development Canada radio frequency exposure limits.
The Wireless Device should be used in such a manner such that the potential for human contact during normal operation is minimized.
This device has also been evaluated and shown compliant with the IC RF Exposure limits under mobile exposure conditions. (antennas are greater than 20cm from a person’s body).
Equipment labeling requirements
The statement shown below, or its equivalent, must appear on the external label of every piece of equipment that contains ZY-IA9QH5 module. If the size of the final equipment is too small to support such a label, the statement described in must appear in the user manual for that equipment.
Contains XN6-IA9QH5V1
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

ZYLUX - logo

Documents / Resources

ZYLUX IA9QH5 5G FPC Module [pdf] Owner's Manual
IA9QH5 5G FPC Module, IA9QH5, 5G FPC Module, FPC Module, Module

References

Leave a comment

Your email address will not be published. Required fields are marked *