I-Zykronix Symphony XL 11.6 Intshi Yokufaka Iphaneli Yokuthinta Umhlahlandlela
Kufakwe ebhokisini
- 1ea Device
- 1ea Mounting bracket
- 4ea Mounting screws
Isingeniso
To install the device you will also need one of the following electrical junction boxes or low-voltage brackets.
Imiyalo ebalulekile yokuphepha
Read, understand and follow ALL safety and installation instructions included in this manual. Failure to follow the included documentation may damage the product and will void the manufacturer’s warranty. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments, in close proximity to heat sources and/or non-recommended locations WILL impede, interfere and/or damage the intended operation of the product. Only use attachments and accessories which have been specified for use by the manufacturer. The use of abrasive, liquid or solvent-based cleaning fluids WILL damage the product. Product Servicing may ONLY be completed by authorized or certified service centers & personnel. For a complete list of product servicing options, please follow instructions included in the product documentation and/or contact the original manufacturer for details.
Le mishini ihlolwe kwatholakala ukuthi iyahambisana nemikhawulo yedivayisi yedijithali yeClass B, ngokulandela ingxenye ye-15 Yemithetho yeCCC.
Le mikhawulo yakhelwe ukuhlinzeka ngokuvikelwa okufanele ekuphazanyisweni okuyingozi ekufakweni kwendawo yokuhlala. Le mishini ikhiqiza, isebenzise futhi ingakhipha amandla amaza omsakazo futhi, uma ingafakiwe futhi isetshenziswe ngokuyalelwa, ingadala ukuphazamiseka okuyingozi ekuxhumaneni nomsakazo. Noma kunjalo, asikho isiqinisekiso sokuthi ukuphazamiseka ngeke kwenzeke ekufakweni okuthile. Uma lo mshini ubangela ukuphazamiseka okuyingozi emsakazweni noma ekwamukelweni kwethelevishini, okunganqunywa ngokucisha nokuvula imishini, umsebenzisi uyakhuthazwa ukuthi azame ukulungisa ukuphazamiseka ngenye yezinyathelo ezilandelayo:
- Qondisa kabusha noma ususe i-antenna etholayo.
- Khulisa ukwehlukana phakathi kwemishini nesamukeli.
- Xhuma okokusebenza endaweni oyisebenzisayo esiteshini esihlukile kunaleso exhunywe kuso umamukeli.
- Xhumana nomthengisi noma uchwepheshe we-TV / we-TV onolwazi ukuthola usizo.
Device – Overview
Note: Only Symphony XL equipped with hue lights.
Ukuhlela ukufakwa
The device is designed to be wall mounted in either Portrait or Landscape orientation, or on tabletop with stand.
Ukufaka idivayisi
A. Mounting height
The recommended mounting height for the device is 57”- 65” (145 cm -165 cm) from the finished floor to the center of the unit.
B. Landscape/Portrait mounting
Device can be mounted and oriented in Portrait or Landscape.
C. Installing the device mounting bracket
The device package includes a stainless steel mounting bracket that MUST be used for installation. Please note the mounting bracket in the box is designed for the US standard 2-gang and supplied Arlington mounting ring supplied in the box. You can order additional stainless steel mounting brackets for UK or European electrical boxes. Verify that the bracket is level before tightening the captive screws on the device. (US mounting bracket included in the box)
D. Connecting the device to power
The device is designed to be powered over the Ethernet connection (PoE) or by connecting a 24Vdc power supply (not included), but not both. If both the PoE and a 24Vdc power supply are connected, the device will draw power from the 24V DC source.
Uxhumano lwe-PoE
PoE connection requires IEEE 802.3af standard. Utilize a network switch or PoE injector that meets this standard. Connect the device using a standard T568A or T568B Ethernet cable from the network switch to the LAN/PoE jack on the back of the device.
I-24V DC Supply Power
You can provide power locally or remotely to device by utilizing a 24V DC power supply (not included). Please note that running the wire through the wall in accordance with local codes when powering locally. If powering remotely, please ensure to use wire of adequate gauge for the length of the run. Please use approved 24V DC power supply.
Verify the polarity of the barrel connector on your power supply before connecting it to the device. The center pin of the device power connector is positive and the outer ring is negative. If the wire is extended, please ensure that the routing is in compliance with local codes.
Plug the connector into the device DC jack on the back of the device.
Powering up the device
The device will automatically power on when power is applied. Wait for the unit to boot up. When it’s connected to a network switch by Ethernet cable, the device will acquire a network address via DHCP and automatically connect to the system.
Temperature ranges/humidity
E. Mounting the device
- Loosen the captive screws of the unit first. Screws should not be moved apart from the unit. Please meet the indicated line.
- Align the mounting frame hooks with the mounting slots and gently pull the unit down the mounting bracket. Make sure the mounting hooks are properly engaged.
- To complete the installation, tighten the 2-captive screws on the bottom part of unit, to secure the device on the mounting bracket.
- For Portrait orientation, rotate mounting bracket and 90 degrees in counterclockwise direction before installation.
Isusa idivayisi
Using a precision Philips head screw driver to loosen the 2-captive screws on the device, then slightly pull straight up from the mounting frame to disengage the unit.
Setting screen orientation
On the touch panel setup screen, select Landscape or Portrait display modes. Press Start device to launch the user interface.
To change orientation:
- Remove power from device.
- Re-apply power to device.
- Select landscape or portrait orientation.
Thank you for including the device as part of the user interface strategy for your customer. The device has been designed to provide years of trouble free operation when wired and installed properly. The device is designed for installation in low humidity indoor environments and should never be installed outdoors or in high humidity areas.
Noma yiluphi ushintsho noma ukuguqulwa okungavunyelwanga ngokucacile ngumnikezeli wale divayisi kungasusa igunya lomsebenzisi lokusebenzisa okokusebenza.
Le divayisi ihambisana nengxenye 15 yemithetho ye-FCC. Ukusebenza kungaphansi kwale mibandela emibili elandelayo: (1) le divayisi ayinakubanga ukuphazamiseka okuyingozi, futhi (2) le divayisi kufanele yamukele noma yikuphi ukuphazamiseka okutholakele, kufaka phakathi ukuphazamiseka okungadala ukusebenza okungafuneki.
Isexwayiso sokuvezwa kwe-RF
Le mishini kufanele ifakwe futhi isetshenziswe ngokuya ngemiyalo enikeziwe futhi izintambo (ama) ezisebenzisela lesi sixhumi kumele zifakwe ukunikezela ngebanga lokwehlukanisa okungenani amasentimitha angama-20 kubo bonke abantu futhi akumele zibambisane noma zisebenze ngokubambisana ne noma iyiphi enye i-antenna noma i-transmitter. Abasebenzisi bokugcina kanye nabafaki kufanele banikeze ngemiyalo yokufaka i-antenna nezimo zokudlulisela zokusebenza ukwanelisa ukuhambisana nokuchayeka kwe-RF.
I-Canada, Izaziso ze-Industry Canada (IC)
Le divayisi ithobelana nemithetho ye-RSS yokungakhokhi ilayisense yase-Canada.
Ukusebenza kungaphansi kwale mibandela emibili elandelayo: (1) le divayisi kungenzeka ingabangeli ukuphazamiseka, futhi (2) le divayisi kufanele yamukele noma yikuphi ukuphazamiseka, kufaka phakathi ukuphazamiseka okungadala ukusebenza okungafuneki kwedivayisi.
Consult the dealer or contact [i-imeyili ivikelwe] ukuthola usizo
English V1.1
Amadokhumenti / Izinsiza
![]() |
Zykronix Symphony XL 11.6 Inch Touch Panel [pdf] Umhlahlandlela wokufaka LBEE5ZZ1PJ, 2AGRR-LBEE5ZZ1PJ, 2AGRRLBEE5ZZ1PJ, Symphony XL 11.6 Inch Touch Panel, Symphony XL, 11.6 Inch Touch Panel |