I-Viatom Blood Pressure Monitor BP2 & BP2A Incwadi Yomsebenzisi

Incwadi yomsebenzisi
I-Blood Pressure Monitor
Imodeli BP2, BP2A

1. Okuyisisekelo

Leli bhukwana liqukethe imiyalo edingekayo yokusebenzisa umkhiqizo ngokuphepha nangokuhambisana nomsebenzi wawo nokusetshenziswa okuhlosiwe. Ukugcinwa kwaleli bhukwana kuyimfuneko yokwenza umkhiqizo ngendlela efanele nokusebenza okuyiyo futhi kuqinisekisa ukuphepha kweziguli nezokusebenza.

1.1 Ukuphepha
Izixwayiso Nezeluleko Zokuxwayisa

  • Ngaphambi kokusebenzisa umkhiqizo, sicela uqinisekise ukuthi ufunde le ncwajana kahle futhi uziqonda ngokuphelele izindlela zokuqapha kanye nezingozi.
  • Lo mkhiqizo wenzelwe ukusetshenziswa okusebenzayo, kepha awuyithathi indawo yokuvakashela udokotela.
  • Lo mkhiqizo awuklanyelwe noma awenzelwe ukuxilongwa okuphelele kwezimo zenhliziyo. Lo mkhiqizo akufanele usetshenziswe njengesisekelo sokuqala noma ukuguqula ukwelashwa ngaphandle kokuqinisekiswa okuzimele ngokuhlolwa kwezokwelapha.
  • Imininingwane nemiphumela ekhonjiswe kumkhiqizo ingeyenkomba kuphela futhi ayinakusetshenziswa ngqo ekuchazelweni noma ekwelashweni.
  • Ungazami ukuzixilonga noma ukuzelapha ngokuya ngemiphumela yokuhlaziya nokuhlaziya. Ukuzihlola noma ukuzelapha kungaholela ekuwohlokeni kwempilo yakho.
  • Abasebenzisi kufanele ngaso sonke isikhathi babonane nodokotela wabo uma bebona ushintsho empilweni yabo.
  • Sincoma ukuthi ungawusebenzisi lo mkhiqizo uma une-pacemaker noma eminye imikhiqizo efakiwe. Landela iseluleko esinikezwa udokotela wakho, uma sikhona.
  • Ungawusebenzisi lo mkhiqizo nge-defibrillator.
  • Ungalokothi ufake umkhiqizo emanzini noma kwezinye iziphuzo. Ungahlanza umkhiqizo nge-acetone noma ngezinye izixazululo eziguqukayo.
  • Ungawushiyi lo mkhiqizo noma uwunikele kumthelela oqinile.
  • Ungawubeki lo mkhiqizo emikhunjini yengcindezi noma kumkhiqizo wokuvala inzalo.
  • Ungahlukanisi futhi uguqule umkhiqizo, ngoba lokhu kungadala ukulimala, ukungasebenzi kahle noma kuphazamise ukusebenza komkhiqizo.
  • Ungaxhumanisi umkhiqizo nomunye umkhiqizo ongachazwanga ku-Instruction for Use, ngoba lokhu kungadala ukulimala noma ukungasebenzi kahle.
  • Lo mkhiqizo awenzelwe ukuthi usetshenziswe ngabantu (kufaka phakathi izingane) abanamakhono avinjelwe ngokomzimba, wezinzwa noma engqondo noma abanesipiliyoni kanye / noma abanolwazi, ngaphandle kokuthi bagadwe ngumuntu onesibopho sokuphepha kwabo noma bathola imiyalelo evela kulo muntu yokuthi uwusebenzisa kanjani umkhiqizo. Izingane kufanele zigadwe kuzungeze umkhiqizo ukuqinisekisa ukuthi azidlali ngawo.
  • Ungavumeli ama-electrode womkhiqizo ukuthi ahlangane nezinye izingxenye eziqhubayo (kufaka phakathi umhlaba).
  • Ungawusebenzisi umkhiqizo nabantu abanesikhumba esibucayi noma i-allergies.
  • UNGAYisebenzisi lo mkhiqizo ezinganeni, ezinganeni, ezinganeni noma kubantu abangakwazi ukuzikhulumela.
  • Ungawugcini umkhiqizo ezindaweni ezilandelayo: izindawo lapho umkhiqizo uvezwa khona yilanga eliqondile, amazinga okushisa aphezulu noma amazinga omswakama, noma ukungcoliswa okukhulu; izindawo eziseduze nemithombo yamanzi noma yomlilo; noma izindawo ezingaphansi kwamathonya anamandla kagesi.
  • Lo mkhiqizo ukhombisa ushintsho kusigqi senhliziyo nomfutho wegazi njll okungaba nezimbangela ezahlukahlukene ezahlukahlukene. Lokhu kungahle kungabi nobungozi, kepha futhi kungadalwa ukugula noma izifo zobukhulu obuhlukile. Sicela uthintane nodokotela wezokwelapha uma ukholwa ukuthi ungaba nokugula noma isifo.
  • Izilinganiso zezimpawu ezibalulekile, njengalezo ezithathwe ngalo mkhiqizo, azikwazi ukukhomba zonke izifo. Ngaphandle kwesilinganiso esithathiwe kusetshenziswa lo mkhiqizo, kufanele ubonane nodokotela wakho ngokushesha uma uhlangabezana nezimpawu ezingakhombisa isifo esibi.
  • Musa ukuzihlola noma ukuzelapha ngokwakho ngesisekelo salo mkhiqizo ngaphandle kokubonisana nodokotela wakho. Ikakhulu, ungaqali ukuthatha noma imuphi umuthi omusha noma ushintshe uhlobo kanye / noma umthamo wanoma imuphi umuthi okhona ngaphandle kokuvunywa kwangaphambili.
  • Lo mkhiqizo awuthathi indawo yokuhlolwa kwezokwelapha noma kwenhliziyo yakho noma okunye ukusebenza komzimba, noma okokuqoshwa kwe-electrocardiogram yezokwelapha, okudinga izilinganiso eziyinkimbinkimbi.
  • Sincoma ukuthi urekhode amajika e-ECG nezinye izilinganiso futhi unikeze udokotela wakho uma kudingeka.
  • Hlanza umkhiqizo kanye ne-cuff ngendwangu eyomile, ethambile noma indwangu dampefakwe ngamanzi kanye nesihlanzi esingathathi hlangothi. Ungalokothi usebenzise utshwala, i-benzene, i-thinner noma amanye amakhemikhali anokhahlo ukuze uhlanze umkhiqizo noma i-cuff.
  • Gwema ukugoqa kabuhlungu ikhafu noma ukugcina ipayipi eligoqwe ngokuqinile isikhathi eside, ngoba ukwelashwa okunjalo kunganciphisa impilo yezingxenye.
  • Umkhiqizo nensipho yakho ayizweli emanzini. Vimbela imvula, izithukuthuku namanzi ekungcoleni umkhiqizo nekhafishi.
  • Ukukala umfutho wegazi, ingalo kufanele icindezelwe ikhefu kanzima ngokwanele ukumisa ukugeleza kwegazi okwesikhashana emthanjeni. Lokhu kungadala ubuhlungu, ukuba ndikindiki noma uphawu olubomvu lwesikhashana engalweni. Lesi simo sizovela ikakhulukazi lapho isilinganiso siphindwa ngokulandelana. Noma yibuphi ubuhlungu, ukuba ndikindiki, noma amamaki abomvu azonyamalala ngokuhamba kwesikhathi.
  • Izilinganiso ezivame kakhulu zingadala ukulimala esigulini ngenxa yokuphazamiseka kokugeleza kwegazi.
  • Xhumana nodokotela wakho ngaphambi kokusebenzisa lo mkhiqizo engalweni ene-arterio-venous (AV) shunt.
  • Xhumana nodokotela wakho ngaphambi kokusebenzisa lesi siqaphi uma ngabe unesisu se-mastectomy noma se-lymph node.
  • Ukucindezelwa kwe-CUFF kungadala okwesikhashana ukulahleka kokusebenza komkhiqizo wokuqapha osetshenziswe ngasikhathi sinye kulowo mzimba ofanayo.
  • Xhumana nodokotela wakho ngaphambi kokusebenzisa umkhiqizo uma unezinkinga ezinzima zokugeleza kwegazi noma ukuphazamiseka kwegazi njengoba ukukhuphuka kwemali kwe-cuff kungadala ukulimala.
  • Sicela uvimbele lokho kusebenza kwemiphumela yomkhiqizo ekukhubazekeni isikhathi eside kokujikeleza kwegazi lesiguli.
  • Musa ukufaka ikhiphu engalweni nomunye umshini osebenza ngogesi wezokwelapha. Imishini kungenzeka ingasebenzi kahle.
  • Abantu abanenkinga enkulu yokujikeleza kwegazi engalweni kufanele babonane nodokotela ngaphambi kokusebenzisa umkhiqizo, ukugwema izinkinga zezokwelapha.
  • Ungazithobi imiphumela yesilinganiso sakho bese uqala ukwelashwa wedwa. Njalo thintana nodokotela wakho ngokuhlola imiphumela nokwelashwa.
  • Musa ukufaka ikhiphu engalweni enenxeba elingapholi, ngoba lokhu kungadala ukulimala okuthe xaxa.
  • Musa ukufaka ikhiphu engalweni ethola i-drip emithanjeni noma ukumpontshelwa igazi. Kungadala ukulimala noma izingozi.
  • Susa izingubo ezikubambayo noma ezijiyile engalweni yakho ngenkathi uthatha isilinganiso.
  • Uma ingalo yeziguli ingaphandle kwebanga lesikwele elishiwo elingabangela imiphumela yokulinganisa engalungile.
  • Umkhiqizo awenzelwe ukuthi usetshenziswe nezingane ezisanda kuzalwa, ezikhulelwe, kufaka phakathi i-pre-eclamptic, iziguli.
  • Ungawusebenzisi umkhiqizo lapho kukhona amagesi avuthayo afana namagesi okubulala izinzwa. Kungadala ukuqhuma.
  • Ungawusebenzisi umkhiqizo endaweni yemishini yokuhlinza ye-HF, i-MRI, noma isithwebuli se-CT, noma endaweni ecebile nge-oxygen.
  • Ibhethri okuhloswe ngalo ukuthi liguqulwe kuphela ngabasebenzi bensizakalo abasebenzisa ithuluzi, futhi ukushintshwa ngabasebenzi abaqeqeshwe ngokwanele kungaholela ekulimaleni noma ekushisweni.
  • Isiguli kungu-opharetha ohlosiwe.
  • Musa ukwenza isevisi nokulungisa ngenkathi umkhiqizo usasebenza.
  • Isiguli singayisebenzisa ngokuphepha yonke imisebenzi yomkhiqizo, kanti isiguli singagcina umkhiqizo ngokufunda ngokucophelela iSahluko 7.
  • Lo mkhiqizo ukhipha amaza omsakazo (RF) kwibhendi engu-2.4 GHz. UNGAWUSEBENZISI lo mkhiqizo ezindaweni lapho i-RF ivinjelwe khona, njengakwindiza. Vala isici seBluetooth kulo mkhiqizo bese ukhipha amabhethri uma usezindaweni ezivinjelwe i-RF. Ngeminye imininingwane ngemikhawulo engahle ibhekiswe kumadokhumenti okusetshenziswa kwe-Bluetooth yi-FCC.
  • UNGAYisebenzisi lo mkhiqizo neminye imishini yezokwelapha kagesi (ME) ngasikhathi sinye. Lokhu kungaholela ekusebenzeni okungalungile komkhiqizo futhi / noma kubangele ukufundwa kwengcindezi yegazi okungalungile kanye / noma nokurekhodwa kwe-EKG.
  • Imithombo yokuphazamiseka kwe-electromagnetic ingathinta lo mkhiqizo (isb. Izingcingo eziphathwayo, ama-microwave cookers, i-diathermy, i-lithotripsy, i-electrocautery, i-RFID, ama-electromagnetic anti-theft systems, kanye nemitshina yensimbi), sicela uzame ukuziqhelelanisa nabo lapho wenza izilinganiso.
  • Ukusetshenziswa kwezesekeli nezintambo ngaphandle kwalezo ezichaziwe noma ezihlinzekwe ngomshini kungaholela ekukhuphukeni kokuphuma kukagesi noma kwehle ukuzivikela komzimba womkhiqizo futhi kuholele ekusebenzeni okungafanele.
  • Ukuhunyushwa okwenziwe lo mkhiqizo kungukutholakala okungenzeka, hhayi ukuxilongwa okuphelele kwezimo zenhliziyo. Konke ukutolika kufanele kwenziwe kabushaviewihlelwe uchwepheshe wezokwelapha ukuze kuthathwe izinqumo zomtholampilo.
  • UNGAWUSEBENZISI lo mkhiqizo lapho kukhona ama-anesthetics avuthayo noma izidakamizwa.
  • UNGAYisebenzisi lo mkhiqizo ngenkathi ushaja.
  • Hlala uthule ngenkathi uqopha i-ECG.
  • Imitshina ye-ECG yenziwe futhi yahlolwa ekuqophelweni kwe-Lead I no-II kuphela.

2. Isingeniso

Ukusetshenziswa Okuhlosiwe
Idivayisi ifakwe ukulinganisa umfutho wegazi noma i-electrocardiogram (ECG) ekhaya noma ezikhungweni zezempilo.
Le divayisi yisiqaphi somfutho wegazi esenzelwe ukusetshenziselwa ukukala umfutho wegazi kanye nezinga lokushaya kwenhliziyo kubantu abadala.
Umkhiqizo uhloselwe ukukala, ukubonisa, ukugcina nokuvuselelaview isigqi se-ECG sesiteshi esisodwa sabantu abadala futhi sinikeza izimpawu ezithile eziphakanyisiwe njengokushaya okuvamile, ukushaya okungajwayelekile, i-HR ephansi ne-HR ephezulu.
2.2 Ukungafani
Lo mkhiqizo uphikisiwe ukuze usetshenziswe ezindaweni ezihamba ngamagciwane.
Lo mkhiqizo uphikisiwe ukuze usetshenziswe ezindizeni.
2.3 Mayelana nomkhiqizo
igama lomkhiqizo: I-Blood Pressure Monitor
Imodeli yomkhiqizo: I-BP2 (faka i-NIBP + ECG), i-BP2A (i-NIBP kuphela)

I-Viatom Blood Pressure Monitor BP2

1. Isikrini se-LED

  • Idethi yokubonisa, isikhathi namandla, njll.
  • Khombisa inqubo nemiphumela yokulinganiswa kwengcindezi yegazi.

Inkinobho yokuqala / yokumisa

  • Amandla ku / Valiwe
  • Ukuvula amandla: Cindezela inkinobho ukuvula.
  • Vala amandla: Cindezela bese ubamba inkinobho ukucisha.
  • Cindezela ukufaka amandla kumkhiqizo bese ucindezela futhi ukuqala ukukala umfutho wegazi.
  • Cindezela ukufaka amandla kumkhiqizo bese uthinta ama-electrode ukuqala ukukala i-ECG.

Inkinobho yememori

  • Cindezela ukuvula kabushaview idatha yomlando.

4. Inkomba ye-LED

  •  Isibani esiluhlaza sivuliwe: ibhethri liyashajwa.
  • Ukukhanya okuluhlaza okwesibhakabhaka kucishiwe: ibhethri ligcwele ngokugcwele hhayi ukushaja

5. I-electrode ye-ECG

  • Bathinte ukuze baqale ukukala i-ECG ngezindlela ezahlukene.

6. Isixhumi se-USB

  • Ixhuma ngentambo yokushaja.

Izimpawu ze-2.4

I-Viatom Blood Pressure Monitor BP2 - Izimpawu

3. Usebenzisa uMkhiqizo

3.1 Shaja ibhethri
Sebenzisa ikhebula le-USB ukushaja umkhiqizo. Xhuma ikhebula le-USB kushaja ye-USB noma kwi-PC. Ukushaja ngokugcwele kuzodinga amahora amabili. Lapho ibhethri lishaja ngokugcwele inkomba izoba luhlaza okwesibhakabhaka.
Umkhiqizo usebenza ngokusetshenziswa kwamandla okuphansi kakhulu futhi inkokhiso eyodwa imvamisa isebenza izinyanga.
Izimpawu zebhethri ezisesikrinini ezibonisa isimo sebhethri zingabonakala esikrinini.
Note: Umkhiqizo awukwazi ukusetshenziswa ngesikhathi sokushaja, futhi uma ukhetha i-adaptha yokushaja yenkampani yangaphandle, khetha eyodwa ehambisana ne-IEC60950 noma i-IEC60601-1.

3.2 Linganisa Umfutho Wegazi
3.2.1 Ukufaka inkomishi yengalo

  1. Songa ikhafu ezungeze ingalo engaphezulu, cishe u-1 kuye ku-2 cm ngenhla kwengqiniba, njengoba kukhonjisiwe.
  2. Beka ikhafula ngqo esikhunjeni, ngoba okokwembatha kungadala ukushaya kwenhliziyo okufiphele futhi kube nomphumela wesilinganiso sokulinganisa.
  3. Ukuvaleka kwengalo ephezulu, okubangelwa ukusonga ishethi, kungavimbela ukufundwa okunembile.
  4. Qinisekisa ukuthi uphawu lwesikhundla somthambo luhambisana nomthambo.

3.2.2 Uhlala kanjani kahle
Ukuze wenze isilinganiso, udinga ukukhululeka futhi uhlale kahle. Hlala esihlalweni imilenze yakho ingavundululiwe izinyawo zakho zibe phansi phansi. Beka ingalo yakho yesobunxele etafuleni ukuze ikhafu ilingane nenhliziyo yakho.

IViatom Blood Pressure Monitor BP2 - Ungahlala kanjani kahle

Qaphela:

  • Umfutho wegazi ungahluka phakathi kwengalo yangakwesokudla nengalo yesobunxele, futhi ukufundwa komfutho wegazi okulinganisiwe kungahluka. IViatom incoma ukuthi ngaso sonke isikhathi isebenzise ingalo efanayo ukukala. Uma ukufundwa kwengcindezi yegazi phakathi kwezingalo zombili kwehluka kakhulu, hlola udokotela wakho ukuthola ukuthi iyiphi ingalo ongayisebenzisela izilinganiso zakho.
  • Isikhathi singama-5s adingekayo ukuze umkhiqizo ufudumale kusuka kubuncane besilinganiso sokugcina phakathi kokusetshenziswa kuze kube yilapho umkhiqizo ulungele ukusetshenziswa kwawo okuhlosiwe lapho izinga lokushisa eliku-20 ° C, kanti isikhathi simayelana nama-5 adingekayo ukuze umkhiqizo uphole kusuka izinga lokushisa eliphakeme lokugcina phakathi kokusetshenziswa kuze kube yilapho umkhiqizo ukulungele ukusetshenziswa kwawo okuhlosiwe lapho izinga lokushisa eliku-20 ° C.

3.2.3 Inqubo yokukala

  1. Cindezela ukufaka amandla kumkhiqizo bese ucindezela futhi ukuqala ukukala umfutho wegazi.
  2. Umkhiqizo uzokhipha inkomishi kancane kancane ngesikhathi sokulinganisa, isilinganiso esivamile sithatha cishe ama-30s.
    I-Viatom Blood Pressure Monitor BP2 - Inqubo yokukala 1
  3. Ukufundwa kwengcindezi yegazi kuzovela lapho kuvela umkhiqizo lapho isilinganiso sesiphelile.
    I-Viatom Blood Pressure Monitor BP2 - Inqubo yokukala 2
  4. Umkhiqizo uzokhipha ngokuzenzakalela igesi yekhafu ngemuva kokuthi isilinganiso sesiphelile.
  5. Cindezela inkinobho ukucisha ugesi ngemuva kwesilinganiso, bese ususa ikhafu.
  6. Cindezela inkinobho yememori kabushaview idatha yomlando. Ukufundwa kwengcindezi yegazi kuzovela kumkhiqizo

Qaphela:

  • Umkhiqizo unomsebenzi wokuvala amandla othomathikhi, ocisha ugesi ngokuzenzakalela ngomzuzu owodwa ngemuva kokulinganisa.
  • Ngesikhathi sokulinganisa, kufanele uhlale uthule futhi ungaminyeli ikhafu. Misa ukukala lapho umphumela wengcindezi uvela kumkhiqizo. Ngaphandle kwalokho isilinganiso singenziwa futhi ukufundwa kwengcindezi yegazi kungahle kunganembi.
  • Umshini ungagcina ukufundwa okuphezulu okungu-100 kwemininingwane yengcindezi yegazi. Irekhodi elidala kakhulu lizobhalwa lapho kufundwa ama-101. Sicela ulayishe idatha ngesikhathi.

Isimiso Sokulinganisa se-NIBP
Indlela yokukala ye-NIBP iyindlela ye-oscillation. Isilinganiso se-Oscillation sisebenzisa ipompo ye-inflator ezenzakalelayo. Lapho ingcindezi iphezulu ngokwanele ukuvimba ukugeleza kwegazi okuvela emithanjeni, khona-ke ibizoncipha kancane, bese iqopha lonke ushintsho lwengcindezelo yenqwaba kunqubo ye-deflation ukubala umfutho wegazi ngokuya nge-algorithm ethile. Ikhompyutha izokwahlulela ukuthi ikhwalithi yesiginali inembile ngokwanele. Uma isiginali inganembi ngokwanele (njengokuhamba okungazelelwe noma ukuthinta ikhafu ngenkathi kukalwa), umshini uzoyeka ukwehlisa noma ukufuthisa kabusha, noma ushiye lesi silinganiso nokubala.
Izinyathelo zokusebenza ezidingekayo ukuthola isilinganiso esinembile sokuphumula komfutho wegazi wesimo somfutho wegazi ophezulu okubandakanya:
- Isikhundla sesineke ekusetshenzisweni okujwayelekile, kufaka phakathi ukuhlala kahle, imilenze engavundlwanga, izinyawo ziyisicaba phansi, emuva nangengalo kusekwe, phakathi kwesikhwama ezingeni le-atrium elungile lenhliziyo.
- Isiguli kufanele sikhululeke ngangokunokwenzeka futhi akufanele sikhulume ngesikhathi senqubo yokukala.
- Imizuzu emi-5 kufanele idlule ngaphambi kokufunda kokuqala.
- Isikhundla se-Operator ekusetshenzisweni okujwayelekile.

3.3 Kala i-ECG
3.3.1 Ngaphambi kokusebenzisa i-ECG

  • Ngaphambi kokusebenzisa umsebenzi we-ECG, naka lawa maphuzu alandelayo ukuze uthole izilinganiso eziqondile.
  • I-electrode ye-ECG kumele ibekwe ngqo esikhumbeni.
  • Uma isikhumba sakho noma izandla zakho zomile, zithambise usebenzisa isikhangisoamp indwangu ngaphambi kokuthatha isilinganiso.
  • Uma ama-electrode e-ECG engcolile, susa ukungcola usebenzisa indwangu ethambile noma ihlumela likakotini dampened ngotshwala obulala amagciwane.
  • Ngesikhathi sokulinganisa, ungathinti umzimba wakho ngesandla othatha ngaso isilinganiso.
  • Sicela wazi ukuthi akumele kube khona ukuxhumana kwesikhumba phakathi kwesandla sakho sokudla nesobunxele. Ngaphandle kwalokho, isilinganiso asikwazi ukuthathwa kahle.
  • Hlala uthule ngesikhathi sokulinganisa, ungakhulumi, futhi ubambe umkhiqizo unganyakazi. Ukuhamba kwanoma yiluphi uhlobo kuzokokotela ukulinganisa.
  • Uma kungenzeka, thatha isilinganiso lapho uhleli hhayi lapho umile.

3.3.2 Inqubo yokukala

1.Cindezela ukufaka amandla kumkhiqizo bese uthinta ama-electrode ukuqala ukukala i-ECG.
→ Indlela A: Hola mina, isandla sokudla siye kwesokunxele
I-Viatom Blood Pressure Monitor BP2 - Inqubo yokukala 3
→ Indlela B: Umholi II, isandla sokudla kuye esiswini sobunxele

I-Viatom Blood Pressure Monitor BP2 - Inqubo yokukala 4

2.Gcina ama-electrode athinta kahle imizuzwana engama-30.

Qhubeka uthinte ama-electrode kamnandi imizuzwana engama-30.

3. Lapho ibha uma igcwele ngokugcwele, umkhiqizo uzokhombisa umphumela wokulinganisa.

I-Viatom Blood Pressure Monitor BP2 - umphumela wokulinganisa

Cindezela inkinobho yememori ukuze uphinde uyisebenziseview idatha yomlando.

Qaphela:

  • Ungawucindezeli umkhiqizo ngokuqinile esikhunjeni sakho, okungabangela ukuphazamiseka kwe-EMG (electromyography).
  • Idivayisi ingagcina amarekhodi ayi-10 aphezulu wedatha ye-ECG. Irekhodi elidala kakhulu lizobhalwa lapho irekhodi le-11 lingena. Sicela ulayishe idatha ngesikhathi.

Isimiso Sokulinganisa se-ECG
Umkhiqizo uqoqa idatha ye-ECG ngomehluko ongaba khona womzimba womzimba nge-electrode ye-ECG, bese uthola idatha eyiyo ye-ECG ngemuva kokuba ampihlungiwe futhi ihlungiwe, bese iboniswa esikrinini.
Ukushaya okungajwayelekile: Uma ijubane lokushintsha kwesilinganiso senhliziyo lidlula umkhawulo othile ngesikhathi sokulinganisa, libhekwa njengokushaya kwenhliziyo okungajwayelekile.
I-HR ephezulu: Isilinganiso senhliziyo > 120 / min
I-HR ephansi: Izinga lokushaya kwenhliziyo < 50 / min
Uma imiphumela yesilinganiso ingahlangabezani ne- “Irregular beat”, “High HR” ne- “Low HR”, bese wehlulela i- “Regular beat”.

3.4 I-Bluetooth
Umkhiqizo we-Bluetooth uzonikwa amandla ngokuzenzakalela kuphela lapho isikrini sikhanya.
1) Qinisekisa ukuthi isikrini somkhiqizo sivuliwe ukugcina umkhiqizo we-Bluetooth unikwe amandla.
2) Qiniseka ukuthi i-Bluetooth yocingo inikwe amandla.
3) Khetha i-ID yomkhiqizo efonini, khona-ke umkhiqizo uzobhangqwa ngempumelelo nefoni yakho.
4) Ungathumela idatha elinganisiwe kufaka phakathi idatha ye-SYS, DIS, ECG efonini yakho.

Qaphela:

  • Ubuchwepheshe be-Bluetooth bususelwa kusixhumanisi somsakazo esinikeza ukuthunyelwa kwedatha okusheshayo nokuthembekile.
    I-Bluetooth isebenzisa ububanzi obungenamalayisense, obutholakala emhlabeni wonke kubhande le-ISM elihloselwe ukuqinisekisa ukuhambisana kokuxhumana emhlabeni jikelele.
  • Ibanga lokubhanqa nokudlulisa umsebenzi ongenantambo ngamamitha ayi-1.5 kokujwayelekile. Uma ukuxhumana okungenawaya kungukubambezeleka noma ukwehluleka phakathi kocingo nomkhiqizo, uzozama ukunciphisa ibanga eliphakathi kwefoni nomkhiqizo.
  • Umkhiqizo ungabhangqa futhi udlulise nefoni ngaphansi kwendawo yokuhlangana okungenantambo (isb. Ama-microwave, omakhalekhukhwini, ama-routers, imisakazo, amasistimu kagesi kagesi wokulwa nokweba, kanye nemitshina yensimbi), kepha omunye umkhiqizo ongenazintambo usengaxhumana nokubhanqa nokudluliswa phakathi kocingo kanye nomkhiqizo ngaphansi kwemvelo engaqinisekile. Uma ifoni nomkhiqizo kukhombisa ukungahambisani, kungadingeka ukuthi ushintshe indawo.

4. Ukudubula Okunenkinga

I-Viatom Blood Pressure Monitor BP2 - Ukudubula Okunenkinga

I-5. Izesekeli

I-Viatom Blood Pressure Monitor BP2 - Izesekeli

I-6. Imininingwane

I-Viatom Blood Pressure Monitor BP2 - Imininingwane 1

I-Viatom Blood Pressure Monitor BP2 - Imininingwane 2

I-Viatom Blood Pressure Monitor BP2 - Imininingwane 3

7. Ukugcinwa nokuhlanzwa

Ukulungiswa kwe-7.1
Ukuvikela umkhiqizo wakho ekulimaleni, sicela uqaphele okulandelayo:

  • Gcina umkhiqizo nezakhi endaweni ehlanzekile nephephile.
  • Ungagezi umkhiqizo nanoma iziphi izakhi noma ucwilise emanzini.
  • Ungahlukanisi noma uzame ukulungisa umkhiqizo noma izingxenye zawo.
  • Ungawubeki umkhiqizo emazingeni okushisa aphezulu, umswakama, uthuli, noma ilanga eliqondile.
  • Isikhafu siqukethe ibhamuza elibamba umoya elizwelayo. Phatha lokhu ngokucophelela futhi ugweme zonke izinhlobo zokuhlunga ngokujija noma ukugoqa.
  • Hlanza umkhiqizo ngendwangu ethambile, eyomile. Ungasebenzisi i-petroli, i-thinner, noma i-solvent efanayo. Amachashaza ku-cuff angasuswa ngokucophelela ngesikhangisoamp indwangu kanye nensipho. Isikhwama akumele sigezwe!
  • Ungayilahli insimbi noma uyiphathe kabi nganoma iyiphi indlela. Gwema ukudlidlizela okunamandla.
  • Ungalokothi uvule umkhiqizo! Ngaphandle kwalokho, ukulinganiswa komkhiqizi kuba okungavumelekile!

7.2 Ukuhlanza
Umkhiqizo ungasetshenziswa kaninginingi. Sicela uhlanze ngaphambi kokuphinda usebenzise kabusha njengokulandelayo:

  • Hlanza umkhiqizo ngendwangu ethambile, eyomile ngotshwala obungama-70%.
  • Ungasebenzisi i-petrol, thinner noma i-solvent efanayo.
  • Hlanza ikhekhe ngokucophelela ngendwangu efakwe 70% kotshwala.
  • Isikhwama akumele sigezwe.
  • Hlanza umkhiqizo kanye nesigaxa sengalo, bese usivumela somile.

7.3 Ukulahlwa


Amabhethri nezinsimbi ezisebenza ngogesi kufanele kulahlwe ngokuya ngemithetho esebenzayo endaweni, hhayi ngemfucuza yabasebenzi.

8. Isitatimende seFCC

I-ID yeFCC: 2ADXK-8621
Noma yiluphi ushintsho noma ukuguqulwa okungavunyelwanga ngokucacile iqembu elibhekele ukuthobela kungabhubhisa igunya lomsebenzisi lokusebenzisa okokusebenza.
Le divayisi ihambisana nengxenye 15 yeMithetho ye-FCC. Umsebenzi ungaphansi kwale mibandela emibili elandelayo:
(1) Le divayisi ayinakubanga ukuphazamiseka okuyingozi, futhi
(2) le divayisi kufanele yamukele noma yikuphi ukuphazamiseka okutholakele, kufaka phakathi ukuphazamiseka okungadala ukusebenza okungafuneki.

Note: Le mishini ihlolwe kwatholakala ukuthi iyahambisana nemikhawulo yedivayisi yedijithali yeClass B, ngokulandela ingxenye ye-15 Yemithetho ye-FCC. Le mikhawulo yakhelwe ukuhlinzeka ngokuvikelwa okufanele ekuphazanyisweni okuyingozi ekufakweni kwendawo yokuhlala. Le mishini ikhiqiza ukusetshenziswa futhi ingakhipha amandla amaza omsakazo futhi, uma ingafakiwe futhi isetshenziswe ngokuyalelwa, ingadala ukuphazamiseka okuyingozi ekuxhumaneni nomsakazo. Noma kunjalo, asikho isiqinisekiso sokuthi ukuphazamiseka ngeke kwenzeke ekufakweni okuthile. Uma lo mshini ubangela ukuphazamiseka okuyingozi emsakazweni noma ekwamukelweni kwethelevishini, okunganqunywa ngokucisha nokuvula imishini, umsebenzisi uyakhuthazwa ukuthi azame ukulungisa ukuphazamiseka ngenye yezinyathelo ezilandelayo:
-Ukuvuselela noma ukuhambisa kabusha i-antenna etholayo.
-Khulisa ukwehlukana phakathi kwemishini nesamukeli.
-Xhuma okokusebenza endaweni oyisebenzisayo esiteshini esihlukile kunaleso okuxhunywe kuso umamukeli.
-Thola usizo kumthengisi noma uchwepheshe onomsakazo / we-TV onolwazi.

Idivayisi ihlolwe ukuhlangabezana nemfuneko yokuchayeka ejwayelekile ye-RF. Idivayisi ingasetshenziswa esimweni sokuvezwa okuphathekayo ngaphandle komkhawulo.

9.Ukuhambisana kwe-Electromagnetic

Umkhiqizo uhlangabezana nezidingo ze-EN 60601-1-2.
ISEXWAYISOIzixwayiso Nezeluleko Zokuxwayisa

  • Ukusebenzisa izesekeli ngaphandle kwalezo ezichazwe kuleli bhukwana kungaholela ekukhuphukeni kokuphuma kukagesi noma kwehle ukuzivikela kwamagesi ngogesi.
  • Umkhiqizo noma izingxenye zawo akufanele zisetshenziselwe eduze noma ukustakwa neminye imishini.
  • Umkhiqizo udinga izixwayiso ezikhethekile maqondana ne-EMC futhi udinga ukufakwa bese usebenza ngokuya ngemininingwane ye-EMC enikezwe ngezansi.
  • Eminye imikhiqizo ingaphazamisa lo mkhiqizo noma ngabe ihlangabezana nezidingo ze-CISPR.
  • Lapho isignali efakiwe ingaphansi kobuncane ampI-litude enikezwe ngemininingwane yezobuchwepheshe, kungahle kube nezilinganiso eziyiphutha.
  • Imishini yokuxhumana ephathekayo nephathekayo ingathinta ukusebenza kwalo mkhiqizo.
  • Eminye imikhiqizo ene-RF transmitter noma umthombo ingathinta lo mkhiqizo (isb. Amaselula, ama-PDA, nama-PC anomsebenzi ongenantambo).

Isiqondisi kanye neSimemezelo - Ukukhishwa kwe-Electromagnetic

Isiqondisi kanye neSimemezelo - Ukuvikelwa Kwamagesi
Isiqondisi kanye neSimemezelo - Ukuvikelwa Kwamagesi
Isiqondisi kanye neSimemezelo - Ukuvikelwa Kwamagesi

Isiqondisi kanye neSimemezelo - I-Electromagnetic Immunity 1

Isiqondisi kanye neSimemezelo - I-Electromagnetic Immunity 2

Qaphela 1: Ku-80 MHz kuye ku-800 MHz, ibanga lokwehlukanisa ibanga lemvamisa eliphakeme liyasebenza.
Qaphela 2: Le mihlahlandlela ingahle ingasebenzi kuzo zonke izimo. Ukusakazwa kwe-Electromagnetic kuthinteka ukumuncwa nokubonisa kusuka kuzakhiwo, izinto nabantu.

a Ama-ISM (izimboni, ezesayensi nezokwelapha) amabhendi aphakathi kuka-0,15 MHz no-80 MHz angama-6,765 MHz kuya ku-6,795 MHz; 13,553 MHz kuya ku-13,567 MHz; 26,957 MHz kuya ku-27,283 MHz; futhi 40,66 MHz kuye ku-40,70 MHz. Amabhendi omsakazo we-amateur aphakathi kuka-0,15 MHz no-80 MHz ayi-1,8 MHz kuya ku-2,0 MHz, 3,5 MHz kuya ku-4,0 MHz, 5,3 MHz kuye ku-5,4 MHz, 7 MHz kuye ku-7,3 MHz , 10,1 MHz kuya ku-10,15 MHz, 14 MHz kuya ku-14,2 MHz, 18,07 MHz kuya ku-18,17 MHz, 21,0 MHz kuya ku-21,4 MHz, 24,89 MHz kuya ku-24,99 MHz, 28,0 , 29,7 MHz kuye ku-50,0 MHz naku-54,0 MHz kuye ku-XNUMX MHz.

b Izinga lokuhambisana kumabhendi emvamisa ye-ISM aphakathi kuka-150 kHz no-80 MHz nakububanzi bemvamisa i-80 MHz kuya ku-2,7 GHz kuhloswe ngalo ukunciphisa amathuba okuthi imishini yokuxhumana ephathekayo / ephathekayo ingadala ukuphazamiseka uma ingeniswa ngokungenhloso ezindaweni zesiguli. Ngalesi sizathu, into eyengeziwe engu-10/3 ifakiwe kumafomula asetshenzisiwe ekubaleni ibanga lokwehlukanisa elinconyiwe labathumeli kulezi zigaba zokuvama.

c Amandla enkambu avela kuzidlulisi ezingaguquki, njengeziteshi eziyisisekelo zezingcingo zomsakazo (amaselula / angenazintambo) kanye nemisakazo yomhlaba ehamba phambili, umsakazo we-amateur, i-AM, ne-FM yokusakazwa komsakazo nokusakazwa kwe-TV akukwazi ukubikezelwa ngokwethiyori ngokunemba. Ukuhlola imvelo kagesi ngenxa yezidlulisi ezingaguquki ze-RF, kufanele kubhekwe inhlolovo yesayithi kagesi kagesi. Uma amandla enkambu alinganisiwe asendaweni lapho kusetshenziswa khona i-Blood Pressure Monitor yeqa izinga lokuhambisana le-RF elingenhla, i-Blood Pressure Monitor kufanele ibhekwe ukuqinisekisa ukusebenza okujwayelekile. Uma kwenziwa ukusebenza okungajwayelekile, kungadingeka izinyathelo ezengeziwe, njengokuqondisa kabusha noma ukuhambisa kabusha i-Blood Pressure Monitor.

d Ngaphezulu kobubanzi bemvamisa engu-150 kHz kuye ku-80 MHz, amandla enkambu kufanele abe ngaphansi kuka-3 V / m.

Kunconywe amabanga wokwehlukanisa phakathi kokuxhumana okuphathekayo nokweselula kwe-RF

uphawu
IShenzhen Viatom Technology Co, Ltd.
4E, Isakhiwo 3, iTingwei Industrial Park, No. 6
ILiufang Road, iBlock 67, iXin'an Street,
Isifunda saseBaoan, iShenzhen 518101 Guangdong
China
www.viatomtech.com
[i-imeyili ivikelwe]

PN: 255-01761-00 Inguqulo: A Oct, 2019

Imanuwali Yomsebenzisi We-Viatom Pressure Monitor BP2 & BP2A - Landa [kuthuthukisiwe]
Imanuwali Yomsebenzisi We-Viatom Pressure Monitor BP2 & BP2A - Thwebula

Joyina ingxoxo

4 Amazwana

  1. Siyabonga ngokwenza kahle. Bengingathanda ukwazi ukuthi singasibeka kanjani isikhathi nosuku. Ozithobayo

    UDanke für die gute Ausführung.
    Ich hätte gerne gewusst wie Uhr und Datum eingestellt werden.
    MFG

Shiya amazwana

Ikheli lakho le ngeke ishicilelwe.