SenseFace 4 Series Multi Biometric Access Control Terminal
“
Specifications
- Near-infrared Flash Camera
- Microphone
- 4.3-inch Touchscreen
- Card Reading Area
- Fingerprint Sensor*
- USB (Type A ; Drive Only)
- Ethernet Port
- RS485 Port
- Power In
- Lock Relay Connection
Product Usage Instructions
1. Overview
The SenseFace 4 Series features a variety of components
including a touchscreen, card reading area, fingerprint sensor, USB
port, Ethernet port, RS485 port, and more. Make sure to remove the
protective film on the fingerprint sensor for accurate
recognition.
2. Installation Environment
- Install indoors only.
- Avoid installation near glass windows, direct sunlight, heat
sources, and moisture. - Handle the device with care and protect it from lightning and
extreme environmental conditions.
3. Standalone Installation
Refer to the provided diagram for connecting various devices
like door sensors, exit buttons, smoke detectors, and locks to the
SenseFace 4 Series.
Connect the door sensor and exit button using the provided
terminals as indicated in the manual.
5. Smoke Detection Connection
Follow the wiring diagram to connect the smoke detector to the
designated terminals on the device.
6. Power Connection
Connect the power supply with higher current ratings to the
specified terminals for proper functioning.
7. RS485 and Wiegand Connection
The RS485 and Wiegand interfaces allow for connection with
compatible devices. Ensure proper wiring based on the intended use
of input or output functions.
8. Ethernet Connection
Configure the IP address and subnet mask for Ethernet connection
as per the provided instructions to enable communication with
network devices.
9. Lock Relay Connection
The system supports both Normally Opened Lock and Normally
Closed Lock configurations. Connect the lock relay terminals
accordingly based on the desired lock behavior.
FAQ
Q: How do I ensure accurate fingerprint recognition?
A: Remove the protective film on the fingerprint sensor before
using it to ensure accuracy.
Q: Can I install the SenseFace 4 Series outdoors?
A: No, the device is recommended for indoor installation only to
prevent damage from environmental factors.
“`
Quick Start Guide
SenseFace 4 Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.
1 Overview
Near-infrared Flash Camera Microphone
84.5mm
21.65mm
175mm
4.3-inch Touchscreen
Card Reading Area Fingerprint Sensor*
USB (Type A ; Drive Only) Reset
Magnetic Tamper Speaker Switch
GND +12V
TX+
RX+ TX-
RX-
Power In
Ethernet
Lock
RS485 Power
Out
NO COM NC 485B 485A 12V-OUT GND
AUX BUT SEN GND GND WG0 WG1
Auxiliary Input Exit Button Sensor
Wiegand Output/Inuput
Note: Y To ensure the accuracy of fingerprint recognition, please remove the
fingerprint sensor protective film before using your fingerprint. Y Not all products have the function with *, the real product shall prevail.
-1-
2 Installation Environment
Please refer to the following recommendations for installation:
INSTALL INDOORS ONLY
AVOID INSTALLATION NEAR
GLASS WINDOWS
AVOID DIRECT SUNLIGHT
AND EXPOSURE
AVOID USE OF ANY HEAT SOURCE
NEAR THE DEVICE
Y Avoid direct contact to sunlight for a long time.
Y Protect the SenseFace 4 Series device from moisture, water, and rain.
Y Handle the SenseFace 4 Series device with care.
Y Make sure that the SenseFace 4 Series device is not installed in close proximity to a sea or other environments where metal oxidation and rust may occur if the
SenseFace 4 Series device is exposed for a long time.
Y Protect the SenseFace 4 Series device from lightning.
Y Make sure that the SenseFace 4 Series device is not working in an acidic or alkaline environment for a long time.
3 Standalone Installation
RS485 RS485 Reader
Smoke Detector
Wireless Doorbell
Door Sensor Lock
Exit Button
TCP/IP
ZKBio CVAccess
Wiegand Card Reader
-2-
4 Exit Button and Door Sensor Connection
NO COM NC 485B 485A 12V-OUT GND
AUX BUT SEN GND GND WG0 WG1
Door Sensor ExitButton
5 Smoke Detection Connection
NO COM NC 485B 485A 12V-OUT GND
AUX COM BUT SEN GND NO GND WG0 WG1
Smoke Detector
-3-
6 Power Connection
GND 12V
GND 12V DC
Recommended Power Supply:
Y 12V ± 10%, at least 3000mA. Y To share power with other devices, use a power
supply with higher current ratings.
7 RS485 and Wiegand Connection
RS485 Reader
485485+ +12V GND
NO COM NC 485B 485A 12V-OUT GND
AUX BUT SEN GND GND WG0 WG1
Wiegand Device
Note: The Wiegand interface is shared, and the user can choose to use either the Wiegand input or Wiegand output function to interface with different Wiegand devices.
-4-
8 Ethernet Connection
RX-
RX+ TX-
TX+
1
2
3
4 5
RJ
45
6
7
8
ZKBio CVAccess
Default IP Address: 192.168.1.201 IP Address: 192.168.1.130
Subnet Mask: 255.255.255.0
Subnet Mask: 255.255.255.0
Click COMM. > Ethernet > IP Address on the SenseFace 4 Series device, to input the IP address and then click OK. Note: In LAN, the IP address of the server (PC) and the device must be in the same network segment when connecting to the software.
9 Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (Normally opened at Power On) is connected with “NO1” and “COM” terminals, and the NC LOCK (Normally closed at Power On) is connected with”NC1″and”COM”terminals. Take NC Lock as an example below:
Device not sharing power with the lock:
Device sharing power with the lock:
NO COM NC 485B 485A 12V-OUT GND
+
+
–
–
+
FR107
–
Normally Closed Lock
DC12V
NO
COM
–
+
NC
485B FR107
485A 12V-OUT
–
+
Normally Closed Lock
GND
–
–
GND +12V
+
DC12V
GND +12V
-5-
+
DC12V
10 User Registration
When there is no super administrator set in the SenseFace 4 Series device, click icon to enter the menu. Add a new user, set their User Role to Super Admin, and the system will request administrator verification before granting access to the menu. It is strongly recommended to register a super administrator initially for security purposes.
Method 1: Register on the SenseFace 4 Series device
Click on > User Mgt. > New User to register a new user. The options include entering the User ID and Name, Setting User Role, Registering Fingerprint*, Face, Card Number, Password and Adding Profile Photo.
2
3
1
-6-
Method 2: Register on ZKBio CVAccess Software Register on the PC
Please set the IP address and cloud service server address, in the Comm. Menu option on the SenseFace 4 Series device. 1. Click Access > Access device > device > Search to search the SenseFace 4 Series
device on the software. When an appropriate server address and port are set on the device, the searched devices are displayed automatically.
2. Click Add in an operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each drop downs and click OK to add the device.
3. Click Personnel > Person > New and fill in all the required fields to register new users in the software.
4. Click Access > device > Control > Synchronize All Data to devices to synchronize all the data into the device including the new users.
For more details, please refer to the ZKBio CVAccess User Manual.
-7-
Register on the Phone Once the ZKBio CVAccess software is installed, the users could enroll their face template via a browser application on their own mobile phone. 1. Click Personnel > Parameters, input`’http://Server address: Port”in the QR Code
URL. The software will automatically generate a QR code. To register users, scan the QR code or log in at ‘http://ServerAddress:Port/app/v1/adreg’ using a mobile phone.
10
2. The users will be displayed in Personnel > Pending Review.
-8-
11 Ethernet and Cloud Server Settings
Click on > COMM. > Ethernet to set the network parameters. If the TCP/IP communication of the SenseFace 4 Series device is successful, the icon will be displayed in the upper right corner of the standby interface. Click on > COMM. > Cloud Server Settings to set the server address. If the SenseFace 4 Series device communicates with the server successfully, the icon ….. will be displayed in the upper right corner of the standby interface.
1
2
1 2
-9-
12 SIP Settings
Calling Options Click >Intercom > SIP Settings > Calling Options to set the SIP common parameters.
Mode 1: Local Area Network
Note: When the SIP Server is enabled, the Contact List menu are not displayed.
Calling by IP Address
1. Set the IP address on the indoor station, Tap Menu > Advanced > Network > 1. Network > 1. IPv4.
Note: Indoor station IP address and the SenseFace 4 Series device IP address must be in the same network segment.
Network
Accounts Network Security
1. Connection Mode 2. IP Address 3. Mask
Static IP 192.168.163.199 255.255.255.0
Maintenance Device
4. Gateway 5. Primary DNS 6. Secondary DNS
192.168.163.1 114.114.114.114 8.8.8.8
2. Click icon on the standby page to enter the call page, users can call the IP address of the indoor station.
Enter IP Address
-10-
Calling by Shortcut 1. Click >Intercom > SIP Settings > Contact List. 2. Click Add, input device number and call address to add a new contact member.
Note: Call address and the SenseFace 4 Series device must be in the same network segment. 3. Click SIP Settings > Calling Shortcut Settings, select any item except admin, and enter the form information you just uploaded. 4. Then you can enter the device number or click shortcut key in the call screen to directly implement the video intercom.
Enter Device Number
Direct Calling Mode 1. Click >Intercom > SIP Settings > Contact List. 2. Click Add, input device number and call address to add a new contact member.
Note: Call address and the SenseFace 4 Series device must be in the same network segment. 3. Click SIP Settings > Calling Shortcut Settings > Call Mode > Direct Calling Mode > Add. Select the IP addresses of the indoor stations that you want to call, then the indoor stations will be displayed in the list. 4. Then you can tap the icon on the device to call the indoor stations at the same time.
-11-
Mode 2: SIP Server 1. Click >Intercom > SIP Settings > Local Settings to enable the SIP server. 2. Click Master Account Setting/Backup Account Setting to set the SIP server
parameters. 3. Click icon on the standby page to enter the call page, once the SIP is set up
correctly, a green dot will appear in the upper right corner of the call page to indicate that the SenseFace 4 Series device is connected to the server. You can call the account name of the indoor station.
Enter indoor station name
Note: When users need to enable SIP server, they need to purchase the server address and password from the distributor, or build the server confidently.
-12-
13 Connect the Wireless Doorbell
This function needs to be used with the wireless doorbell. First, power on the wireless doorbell. Then, press and hold the music button for 1.5 seconds until the indicator flashes to indicate it’s in pairing mode. After that, click on the SenseFace 4 Series device icon , if the wireless doorbell rings and the indicator flashes, it means the connection is successful.
Volume Button Music Button
SenseFace 4 Series
Wireless Doorbell
After a successful pairing, clicking the icon of SenseFace 4 Series device will ring the wireless doorbell.
Note: Generally, each SenseFace 4 Series device connects to 1 wireless doorbell.
-13-
14 ONVIF Settings
This function needs to be used with the Network Video Recorder (NVR). 1. Set SenseFace 4 Series device to the same network segment as the NVR. 2. Click >Intercom > ONVIF Settings to set the User Name and Password.
Note: If the Authentication function is disabled, then there is no need to input the User Name and Password when adding the device to the NVR.
2 1
3. On the NVR system, click Start > Menu > Channel Manage > Add Channel > Refresh to search for the SenseFace 4 Series device.
-14-
4. Select the checkbox for the device you want to add and edit the parameters in the corresponding text field, then click on OK to add it to the connection list.
5. After successfully adding, the video image obtaining from the device can be viewed in real-time.
For more details, please refer to the NVR User Manual.
-15-
ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 – 82109991 Fax : +86 755 – 89602394 www.zkteco.com
Copyright © 2024 ZKTECO CO., LTD. All Rights Reserved.
Documents / Resources
![]() |
ZKTECO SenseFace 4 Series Multi Biometric Access Control Terminal [pdf] User Guide SenseFace 4 Series Multi Biometric Access Control Terminal, SenseFace 4 Series, Multi Biometric Access Control Terminal, Access Control Terminal, Control Terminal, Terminal |