SenseFace 3 Series Based Face Recognition Device

Product Information

Specifications:

  • Product Name: SenseFace 3 Series
  • Version: 1.0
  • Dimensions: 6.54″(166.0mm) x 0.98″(25.0mm) x 2.48″(63.0mm)
  • Features: Microphone, Camera, Near-Infrared Flash, 2.8-inch
    Touch Screen, Fingerprint Sensor, Card Reading Area, Reset
    Function, USB Interface, Speaker, Tamper Switch, Terminal
    Block

Product Usage Instructions

1. Overview

Ensure to refer to the actual product for accurate functions as
mentioned in the manual.

2. Installation Environment

  • Install indoors only
  • Avoid installation near glass windows
  • Avoid direct sunlight and exposure
  • Avoid use of any heat source near the device

3. Device Installation

Follow these steps for device installation:

  1. Attach the mounting template sticker to the wall and drill
    holes accordingly.
  2. Fix the backplate on the wall using mounting screws.
  3. Pass wires through the wiring hole and connect them to the
    device.
  4. Snap the device onto the backplate and push it down into
    place.
  5. Secure the device to the backplate with a security screw.

4. Standalone Installation

For standalone installation, ensure you have the necessary
components like Door Sensor, Wiegand Card Reader, RS485 Lock
Reader, Exit button, Smoke Detector, Wireless Doorbell, TCP/IP,
etc.

5. Terminal Block

The terminal block includes various interfaces like Network
Interface, Lock RS485 Power Out, RX-, RX+, TX-, GND, TX+, 12V, NO
COM NC, 485B 485A, 12VOUT GND, AUX BUT SEN GND GND WD0 WD1, Power
In, Auxiliary Input Exit Button Door Sensor, Wiegand Out / In.

6. Ethernet Connection

To establish an Ethernet connection between the device and
software, set the IP address and subnet mask as per provided
examples.

7. Power Connection

Use an AC Adapter DC12V, 3A for power connection. Recommended
adapter: 12V, 3A.

8. Exit Button, Door Sensor & Auxiliary Connection

Connect the Exit Button, Door Sensor & Auxiliary components
as per the provided instructions.

9. RS485 Connection

Connect the RS485 components as per the provided
instructions.

10. Lock Relay Connection

The system supports both Normally Opened Lock and Normally
Closed Lock connections. Follow the provided instructions for
proper connection.

11. Wiegand Reader Connection

Connect the Wiegand Reader components as per the provided
instructions.

Frequently Asked Questions (FAQ)

Q: Can I install the device outdoors?

A: No, it is recommended to install the device indoors only.

Q: What is the recommended power adapter for this device?

A: The recommended AC adapter is DC12V, 3A. For sharing power
with other devices, use an adapter with higher current ratings.

“`

Quick Start Guide
SenseFace 3 Series
Version: 1.0
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual.

1.Overview

6.54″(166.0mm)

0.98″(25.0mm)
2.48″(63.0mm)
Note: Not all products have the function with , the real product shall prevail.
1

Microphone Camera Near-Infrared Flash 2.8-inch Touch Screen Fingerprint Sensor Card Reading Area Reset USB Interface Speaker Tamper Switch Terminal Block

2.Installation Environment

INSTALL INDOORS ONLY

AVOID INSTALLATION NEAR
GLASS WINDOWS

AVOID DIRECT SUNLIGHT
AND EXPOSURE

AVOID USE OF ANY HEAT SOURCE
NEAR THE DEVICE

3.Device Installation

Install on the wall
Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
Fix the backplate on the wall with the wall mounting screws. After passing the wires through the wiring hole and connecting them to the
device, and then snap the device onto the backplate and push it down into place. Fasten the device to the backplate with a security screw.

1

Baseline

2

1.5m

3

4

1

2

2

4.Standalone Installation

Door Sensor

Wiegand Card Reader

RS485
Lock RS485 Reader

Exit button

Smoke Detector
Wireless Doorbell

TCP/IP

ZKBio CVAccess

5.Terminal Block

Network Interface
Lock RS485 Power Out

RX-

RX+

TX-

GND

TX+

12V

NO COM NC 485B 485A 12VOUT GND

AUX BUT SEN GND GND WD0 WD1

Power In
Auxiliary Input Exit Button Door Sensor
Wiegand Out / In

3

6.Ethernet Connection
Establish the connection between the device and the software using an Ethernet cable. An illustrative example is provided below:

ZKBio CVAccess

Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0

IP address: 192.168.1.130 Subnet mask: 255.255.255.0

Tap on to enter the main menu. And then click on [Comm.] > [Ethernet] > [IP Address] to input the IP address. Note: In LAN, IP addresses of the server (PC) and the device must be in the same network segment when connecting to the software.

7.Power Connection

AC Adapter DC12V, 3A
Recommended AC adapter: 12V, 3A To share power with other devices, use an AC adapter with highercurrent ratings.
4

8.Exit Button, Door Sensor & Auxiliary Connection

NO COM

Smoke Detector +12V DC

AUX

BUT

SEN

GND

GND

WD0

WD1

Exit button

9.RS485 Connection

Door Sensor

NO COM NC 485B 485A 12VOUT GND
5

485+ 485+12V GND
RS485 Reader

10.Lock Relay Connection

The system supports both Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally opened at power on) is connected with ‘NO’ and ‘COM’ terminals, and the NC LOCK (normally closed at power on) is connected with ‘NC’ and ‘COM’ terminals. Take NC Lock as an example below:
1) Device not sharing power with the lock2)Devicesharing power with the lock

+12V DC

GND

12V

+12V DC
FR107
Normally Closed Lock

NO COM NC 485B 485A 12VOUT GND

+12V DC

GND

12V

NO COM NC 485B 485A 12VOUT
FR107
GND

Normally Closed Lock

11.Wiegand Reader Connection

NO COM NC 485B 485A 12VOUT GND

AUX BUT SEN GND GND WD0 WD1

WD0
WD1 Wiegand Device
GND +12V

Note: The Wiegand interface is shared, and the user can choose to use either the Wiegand input or Wiegand output function to interface with different Wiegand devices.
6

12.User Registration
Click to enter the Main Menu screen. When a super administrator is set up, administrator verification is required when entering the menu. For security purposes, it is recommended to register a super administrator when using it for the first time. Method 1: Registering on the device Click >[UserMgt.]>[NewUser]toregisteranewuser.TheoptionsincludeenteringtheuserIDandName,settingUserRoleandAccess Control Role, registering Face, Fingerprint, Card Number, Password and Profile Photo.
7

Method 2: Register on ZKBio CVAccess software Please set the IP address and cloud service server address in the COMM. menu option on the device. 1. Click [Access] > [Access Device] > [Device] > [Search] to search the device on
the software. When an appropriate server address and port is set on the device, the searched devices are displayed automatically.
2. Click [Add] in operation column, a new window will pop-up. Select Icon type, Area, and Add to Level from each dropdowns and click [OK] to add the device.
3. Click [Personnel] > [Person] > [New] and fill in all the required fields to register a new users in the software.
4. Click [Access] > [Device] > [Control] > [Synchronize All Data to Devices] to synchronize all the data to the device including the new users. For more details, please refer to the ZKBio CVAccess User Manual.
8

Method 3: Register on the phone Once the ZKBio CVAccess software is installed, the users could enroll their face via a browser application on their own mobile phone. 1. Click [Personnel] > [Parameters], input`’http://Server address: Port”in the QR
Code URL bar. The software will automatically generate a QR code. Scan the QR code or login onto `’http://Server address: Port/app/v1/adreg” by the mobile phone to register users.
10
2. The users will be displayed in [Personnel] > [ Pending Review].
9

13.Ethernet and Cloud Server Settings
Click > [COMM.] > [Ethernet] to set the network parameters. If the TCP/IP communication of the device is successful, the icon will be displayed in the upper right corner of the standby interface. Click > [COMM.] > [Cloud Server Setting] to set the server address and server port, that is, the IP address and port number of the server after the software is installed. If the device communicates with the server successfully, the icon will be displayed in the upper right corner of the standby interface.
Note: While pairing the device with ZKBio CVAccess software. Make sure that the option Enable Domain Name is disabled and the correct server address and port are entered.
10

14.Con guring Wi-Fi
Tap on to view the menu. Click [COMM.] > [Wi-Fi Settings] to configuring Wi-Fi. When Wi-Fi is enabled, select the searched network. Enter the password, and click Connect to Wi-Fi (OK). The connection succeeds, with icon displayed on the status bar.You can also select AddWi-Fi Network to addWi-Fi manually.

15.Connect the Wireless Doorbell

This function needs to be used with the wireless doorbell.
First, power on the wireless doorbell. Then, press and hold the music button for 1.5 seconds until the indicator flashes to indicate it’s in pairing mode. After that, click on the device icon , if the wireless doorbell rings and the indicator flashes, it means the connection is successful.

Volume Button

Music Button
1

2
Wireless Doorbell 11

After a successful pairing, clicking the icon of the device will ring the wireless doorbell. Note: Generally, each device connects to one wireless doorbell.
16.SIP Settings Setting call options on the device
Click >[Intercom] > [SIP Settings] > [Call Options] to set the SIP common parameters.
Mode 1: Local Area Network Note: When the SIP Server function is enabled, the Contact List menu are not displayed. To use Contact List, turn off the SIP Server.
Calling by IP Address 1. SettheIPaddressontheindoorstation,Tap[Menu]>[Advanced]>[Network] >
[1. Network] > [1. IPv4]. Note: Indoor station IP address and the device IP address must be in the same network segment.
12

Accounts Network Security Maintenance Device

Network

1. Connection Mode

2. IP Address

1

3. Mask

4. Gateway 5. Primary DNS 6. Secondary DNS

Static IP 192.168.163.199 255.255.255.0 192.168.163.1 114.114.114.114 8.8.8.8

2. Click icon on the standby page to enter the call page, users can call the IP address of the indoor station.
192.168.163.199
3
2 4 5
Calling by Shortcut 1. Click >[Intercom]>[SIPSettings]>[ContactList]. 2. Click[Add],inputdevicenumberandcalladdresstoaddanewcontactmember.
Note: Call address and the device must be in the same network segment. 3. Click[SIPSettings]>[CallingShortcutSettings], select any item except admin,
and enter the form information you just uploaded. 4. Then you can enter the device number or click shortcut key in the call screen
to directly implement the video intercom.
13

Enter Device Number or
Direct Calling Mode 1. Click >[Intercom]>[SIPSettings]>[ContactList]. 2. Click[Add],inputdevicenumberandcalladdresstoaddanewcontactmember.
Note: Call address and the device must be in the same network segment. 3. Click [SIP Settings] > [Calling Shortcut Settings] > [Call Mode] > [Direct Calling
Mode] > [Add]. Select the IP addresses of the indoor stations that you want to call, then the indoor stations will be displayed in the list. 4. Thenyoucantapthe icononthedevicetocalltheindoorstationsatthesame time.
14

Mode 2: SIP Server 1. Click >[Intercom]>[SIPSettings]>[LocalSettings]toenabletheSIPserver. 2. Click [Master Account Setting] / [Backup Account Setting] to set the SIP server
parameters. 3. Click icon on the standby page to enter the call page, once the SIP is set up
correctly, a green dot will appear in the upper right corner of the call page to indicate that the device is connected to the server. You can call the account name of the indoor station.
Enter Indoor Station Name
Note: When users need to enable SIP server, they need to purchase the server address and password from the distributor, or build the server confidently.
15

17.ONVIF Settings
This function needs to be used with the Network Video Recorder (NVR). 1. Set the device to the same network segment as the NVR. 2. Click > [Intercom] > [ONVIF Settings] to set the User Name and Password.
Note: If the Authentication function is disabled, then there is no need to input the User Name and Password when adding the device to the NVR.
3. OntheNVRsystem,click[Start]>[Menu]>[ChannelManage]>[AddChannel] > [Refresh] to search for the device.
16

4. Select the checkbox for the device you want to add and edit the parameters in the corresponding text field, then click on [OK] to add it to the connection list.
5. After successfully adding, the video image obtaining from the device can be viewed in real-time.
For more details, please refer to the NVR User Manual.
17

ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China. Phone : +86 769 – 82109991 Fax : +86 755 – 89602394 www.zkteco.com
Copyright 2024 ZKTECO CO., LTD. All Rights Reserved.

Documents / Resources

ZKTECO SenseFace 3 Series Based Face Recognition Device [pdf] User Guide
ZK_SenseFace-3-Series-QSG_EN_v1.0_20240318, ZK_SenseFace-3-Series-QSG_EN_v1.0_20240318_105X145mm, ZK_SenseFace-3-Series-QSG_EN_v1.0, SenseFace 3 Series Based Face Recognition Device, SenseFace 3 Series, Based Face Recognition Device, Face Recognition Device, Recognition Device

References

Leave a comment

Your email address will not be published. Required fields are marked *