Function/Application

The CondenseSpot is an infrared temperature measuring instrument with an integrated hygrometer that permits non-contact temperature measurements on surfaces as well as the measurement of relative humidity and ambient temperature. The instrument measures how much electromagnetic energy is emitted in the infrared wavelength range and uses this information to calculate surface temperature. During this process, two additional integrated sensors detect relative humidity and ambient temperature. The dew point is also calculated.

Laserliner Condense Spot XP - figure 1Laserliner Condense Spot XP 3

1 low battery charge 6 min/max and average measurement values
2 stability progress bar for relative
humidity measurement
7 dew point temperature (D Temp) and ambient temperature  (A Temp) in °C or °F
3 laser beam switched on, temperature measurement (infrared) 8 condense water indicator
4 measurements in °C or °F 9 last measurement value will be displayed brie y (7s)
5 relative humidity in % 10 replace battery

Laserliner Condense Spot XP 4Laserliner Condense Spot XP 5

Laser: The laser is a targeting aid to sight the location for the infrared measurement. Only the surface‘s temperature is measured. Laserliner Condense Spot XP 6

7. Displaying Min/Max/Avg, Ambient temperature, Dew point temperatureLaserliner Condense Spot XP 7

8. Dew point temperature is the temperature at which current air conditions would produce condensation. The CondenseSpot calculates the dew point temperature from ambient temperature, relative humidity, and ambient atmospheric pressure. In combination with the infrared thermometer, thermal bridges are easily detected. If the temperature of the measured location drops below the dew point, condensation (water) will form on the surface.Laserliner Condense Spot XP 8

9. Ubuntu bezizalwane
The relative humidity is indicated in relation to the maximum possible humidity (100 %) at which air forms water vapor. The ability of air to hold water is temperature-dependent. Thus humidity is the volume of water vapor in the air. The range for humidity is 0 … 100%. 100% = saturation point.
Under these conditions for temperature and atmospheric pressure, air cannot absorb any more water.Laserliner Condense Spot XP 9

When temperature fluctuations (± 1 °C) and/or changes to relative humidity (± 1%) are rapid, the sensor must adapt itself to the new conditions. An hourglass with a progress bar is displayed during this stabilization process.
During this process, displayed values are only approximations. Only after these symbols have been switched off is a stable value presented which represents maximum accuracy.

10. Setting the emission coef cientLaserliner Condense Spot XP 10

A built-in sensor head detects the material/surface-specific infrared rays emitted by every object. The level of these emissions is determined by the material‘s emission coefficient (0.01 to 0.99). This instrument is preset to an emission coefficient of 0.95, which is applicable to most organic materials as well as plastics,  ceramics, wood, rubber, and stone. For details of those materials with a different emission coefficient, please refer to the table.

I-coefficient yokukhutshwa okungaziwayo:
Apply masking tape or black matt paint to the surface of the area whose temperature you wish to measure. Wait until the tape/paint has heated up.
The temperature of the surface can then be measured with an emission coefficient of 0.95.

11. Emission coef cient tables
Iintsimbi ezingezizo

Asbestos 0.93 Limestone 0.98
Asphalt 0.95 Marble
Black, dull finish Greyish, polished
0.94
0.93
lebasalt 0.70
Isitena, esibomvu 0.93
ICarborundum 0.90 Ukuxoka 0.93
ukubumba 0.95 ukupeyinta
Mnyama, Mat
Heat-resistant White
0.96-0.98 0.92
0.85 -0.95
iTshayina
Brilliant white With glaze
0.7 - 0.75 0.92
Ibala 0.95 Iphepha
Yonke imibala
0.95-0.97
Coal Non-oxidised 0.8-0.9
iplastiki
Translucent PE, P, PVC
0.95
0.94
Concrete, plaster, mortar 0.93
umqhaphu 0.77 IRubber
lukhuni
Ithambile, ingwevu
0.94-0.95 0.89
Izinto zodongwe, Mat 0.93
Indwangu 0.95
iglasi 0.85 -0.94 Iglasi yeQuartz 0.93
IGraphite 0.7 -0.8 ikhephu 0.80
Igravel 0.95 Umhlaba 0.9 -0.98
Gypsum 0.8-0.95 Tar 0.79 -0.84
Heat sink Black, anodized 0.98 Iphepha leTar 0.91 -0.93
Ipeyinti yokuguqula 0.94
Ulusu lomntu 0.98 Iphepha lodonga, elikhanyayo 0.88-0.90
umkhenkce
Cacileyo
Ngeqabaka enzima
0.97
0.98
amanzi 0.93
iinkuni
Ukunganyangwa
Beech, icwangcisiwe
0.8 -0.95 0.94
Lamoni 0.3 -0.4
Lime maim brick 0.95

Metals

Alloy A3003 Oxidised
Irhangqwe
0.3
0.1 - 03
Intsimbi, eyenziwe ngokwenziwa Mat 0.9
Khokela
Elihle
Oxidised
0.4
0.2 - 0.6
Aluminium Oxidised
Iphosiwe
0.2 - 0.4
0.04 - 0.06
Molybdenum Oxidised 0.2 - 0.6
Brass
Iphosiwe
Oxidised
0.3
0.5
Nickel Oxidised 0.2 - 0.6
Platinum Black 0.9
ubhedu
Oxidised
Elect. terminal strips
0.4 - 0.8 0.6 steel
Cold rolled Ground plate
Ipleyiti ekhazimlisiweyo
Ingxubevange (8% nickel,
18% chromium) Galvanised Oxidised
Heavily oxidised
Freshly rolled Rough, flat surface
Rusty, red
Sheet, nickel-plated Sheet, rolled
0.7 - 0.9 0.4 - 0.6 0.1
0.35
0.28
0.80
0.88
0.24
I-0.95- 0.98 0.69
0.11
0.56
Haynes Metal alloy 0.3 - 0.8
Ikhoneli
Oxidised
Sandblasted Electropolished
0.7 - 0.95 0.3 - 0.6 0.15
intsimbi
Oxidised
Ngomhlwa
With red rust
0.5 - 0.9 0.5 - 0.7 0.61 - 0.85
Intsimbi, intsimbi
Oxidised
Non-oxidised
Ubunzima obunyibilikisiweyo
0.6 - 0.95 0.2
02 - 03
Zinc Oxidised 0.1

data Technical

Technical revisions reserved. 08.13

Measured quantities °C (°F) infrared temperature measurement, %rH relative humidity, °C (°F) ambient temperature measurement
Infrared measurement range -40 °C … 350 °C (-40 °F … 662 °F)
Ambient temperature measurement range -10 °C … 60 °C (14 °F … 140 °F)
Relative humidity measurement range 20 % … 90 % rH
Dew point indicator -20 ° C… 60 ° C
Ukuchaneka kwe-infrared t 1 °C (-10 °C … 60 °C); t 1.5 °C (< 10 °C and > 60 °C) or t 1.5 % whichever value is greater
Ambient temperature accuracy t 2 °C
Relative humidity accuracy t 3%
Isisombululo seso 0.1 ° C
Relative humidity resolution 1%
Dew point resolution 1 ° C
I-coefficient yokukhutshwa Adjustable, 0.10 … 0.99
lobushushu yokusebenza 0 ° C… 40 ° C
bushushu egcinwe -20 ° C… 70 ° C
I-Optics 8:1 (distance: measured spot)
Ivelength ye Laser 650 nm
Uhlobo lwe laser Class 2, < 1 mW
Power unikezelo Type 9 V E block battery

General safety instructions.
Attention: Do not look directly into the laser beam! The laser may not get into the hands of children! Do not point this device unnecessarily toward persons.Laserliner Condense Spot XP - warning

Imiyalelo ye-EU kunye nokulahlwa
Laserliner Condense Spot XP - ce
Esi sixhobo sihambelana nayo yonke imigangatho eyimfuneko yokuhamba ngokukhululekileyo kwempahla ngaphakathi kwe-EU.
Le mveliso sisixhobo sombane kwaye kufuneka siqokelelwe ngokwahlukeneyo ukuze silahlwe ngokwe-European Directive kwinkunkuma yombane kunye nezixhobo zombane.
Ukhuseleko olongezelelweyo kunye nezaziso ezongezelelweyo apha: www.laserliner.com/info
CondenseSpotLaserliner Condense Spot XP - CondenseSpot

Laserliner Condense Spot XP - iconINKONZO
Umarex GmbH & Co KG
-Laserliner -
Möhnestraße 149, 59755 Arnsberg, eJamani
Umnxeba: +49 2932 638-300, Ifeksi: +49 2932 638-333
[imeyile ikhuselwe]
Umarex GmbH & Co KG
Donnerfeld 2
Ngo-59757 eArnsberg, eJamani
Umnxeba: +49 2932 638-300, Ifeksi: -333
www.laserliner.com
Laserliner - uphawuLaserliner Condense Spot XP - ce

Amaxwebhu / Izibonelelo

Laserliner Condense Spot XP [pdf] Incwadi yomsebenzisi
Condense Spot XP

Ushiye uluvo

Idilesi yakho ye email aziyi kupapashwa.