WVC-2800 Wireless Series R3 Micro Inverter User Manual
WVC-2800 Wireless Series R3 Micro Inverter

IoT Monitoring Platform

Smart mobile “core” life 

IoT Monitoring Platform

App Store Logo Google Play Logo

  • CO-2 induced environmental analysis
  • Daily and total energy generation inkWh
  • Actual DC input voltage, current and power
  • Actual AC output voltage, current and power
  • Inverter temperature
  • Historical (daily, weekly, monthly) power curve
  • Power losses due to weather induced effects
  • Optional limitation of power output
  • Online switch for the inverter start stop

IoT Monitoring Platform

Symbols CO-2 induced environmentalanalysis
Symbols Daily and total energy generation in kWh
Symbols Actual DC input voltage, current and power
Symbols Actual AC output voltage, current andpower
Symbols Inverter temperature
Symbols Optional limitation of power output
Symbols Online switch for the inverter start stop
Symbols Historical (daily, weekly, monthly) power curve

modelWVC-2800
Recommend use panels4*875Watt
Output voltage mode120/230V Auto switch
PV Open circuit voltage30-54VOC
Operating voltage range22-60V
Starting voltage range22-60V
short-circuit  current4*32A
Maximum working current4*27A
Output parameters@120V@230V
Output peak power3000Watt3000Watt
Rated output power2800Watt2800Watt
Output current23.5A12.2A
AC voltage range80-160VAC180-280VAC
AC frequency range48-51Hz/58-61Hz48-51Hz/58-61Hz
Power factor>95%>95%
Number of branch connections2PCS (Single)4PCS (Single)
Output efficiency

 

@120V

 

@230V

 

Static MPPT efficiency99.5%99.5%
Max output efficiency95%95%
Loss of power at night<0.5W<0.5W
Total current harmonics<5%<5%
Appearance and technical features
Temperature range40°c to +65°C
Size ( LxWxH)370mmx300mmx41.6mm
Net amount3.0kg
Waterproof gradeIp65 NEMA3R
Heat dissipation modeSelf-cooling
Communication mode433MHz
Power transmission modeReverse t ran sm i ssio n, Lo ad priority
monitoring systemAPP
Electromagnetic DetectionEN61000-6-1:2007 EN6100-6-3:2007 +Al:2011+AC:2012
Power Grid standardEN50549-1, EN 50549-2, NBR 16149:2013, UL1741
Power grid detectionEC/EN 62109-1, IEC/EN 62109-2, IEC 62116, IEEE 1547
CertificateCE, ETL, IN METRO, Patented technology
Packing weight
SpecificationsEach (Packing)Box( 4PCS)
weight4.36KG18.38 KG
Size430x375xl40mm430x405x380mm

Detailed

Detailed

System diagram

System diagram 

Description of the connector and cable core of the micro inverter 

Description

Warning Icon Note: You can purchase a professionally customized AC bus with a T-type connector.
Use this AC bus as the AC bus for each branch. Connect it hand in hand to form a modular micro-inverter branch wiring system.

LED indicator function of micro inverter

  1. Red light keeps on ——————The equipment enters the preparatory working state;
  2. Red light flashes ——————-The device enters the delayed start-up stale;
  3. Blue light flashes quickly ———–MPPT maximum power point search status;
  4. Blue light keep son———-1v, PPT maximum power point locked state;
  5. Blue light turns to red light for along time – a)Island protection; b)Frequency protection; c)Fault; d)Software shutdown;
    e)AC voltage over-voltage protection; f)DC voltage over-voltage protection;

Normal working indicator flashing process 

Connect the micro-inverter correctly to the AC and DC terminals and then power on:
The red light keeps on for 3 seconds —->the red light flashes for 30 seconds – > the blue light flashes quickly (MPPT maximum power point search)–> the blue light keeps on, (MPPT lock).

DOWNLOAD Cloud Intelligence APP

Please use the QR code to scan and install the “Cloud Intelligence” client application,System version: Android 5.0, !OS 9 and above

DOWNLOAD Cloud Intelligence APP

App Store Logo Google Play Logo

QR Code

Icons  note

a) Connect the two communication antennas on the collector (Modem) as required;
b) Place the collector in an appropriate location to ensure that the wifi signal source can be received normally and Form a good Entry equipment
When the smart APP changes to the QR code scanning state, scan the QR code label at the bottom of the Modem. At this time, the APP will automatically collect the body code of the Modem,and automatically jump to the Wi-Fi connection page, and enter the current Wi-Fi Click Next after the password;
communication distance with the inverter;
c) The connected Wi-Fi network needs to be in 2.4G communication mode;
d) Please reset the collector for the first use;

Icons Reset

Press and hold the reset button for more than 5 seconds, and Reday will go out and light up again after 5 seconds.
Release the button at this time, and the device will complete the reset.

Add device

Add device

Open the intelligent monitoring software “Cloud Intelligence” APP to log in Account, click the “+” icon in the upper right corner to start adding.
If a device has been created under the current account,(You can click on the device icon below to enter the details page for query or operation)

Entry equipment

Entry equipment

When the smart APP changes to the QR code scanning state, scan the QR code label at the bottom of the Modem. At this time, the APP will automatically collect the body code of the Modem,and automatically jump to the Wi-Fi connection page, and enter the current Wi-Fi Click Next after the password;

Distribution network

Distribution network

Connect the Modem to the power supply as required, and quickly press the “Reset” button.
When the “Reday” indicator turns from a long on state to a fast flashing state, the Modem will enter the network distribution state;

Initialization

Initialization

After completing the network configuration of the modem, return to the phone initialization device operation page,check the “I have completed the above operations” below and click the “start connection” button, then the page will jump to the signal search page and the Link on the modem The indicator light will become a fast flashing state.
When a WiFi signal is found,the indicator light will flash slowly until the network configuration is completed, and the — 39.8″ Temperature indicator light will return to a steady state.
The page jumps to the completion page, please click “Finish”

Add inverter

Add inverter

When the initialization is completed, please click the “Settings” menu in the upper right corner, find the inverter list item on the setting page, click the “Edit” button, and fill in the 8-digit code on the inverter to complete the inverter Add to.

Remarks

  1.  When multiple inverters need to be added, the in the English state,”,” comma separated and ended. Such as: 60001234, 6000E312,
  2. Each Modem can monitor 60 inverters at the same time;3. A total of 2 lists, each list can be filled with 30 inverter codes;

Features

Icons

Smart APP can realize real-time data transmission with the cooperation of Alibaba Cloud loT Through graphs and graphic displays in time, users can understand the operation of the power station. The user can monitor the operation and adjust the output power function of the system.

Features

INTELLIGENT lot MONITORING MODEM
Number of data collectors per Modem Built-in WiFi loT data terminal Can be used on any smart device (Android/iOS)

  • CO-2 induced environmental analysis
  • Daily and total energy generation in kWh
  • Actual DC input voltage, current and power
  • Actual AC output voltage, current and power
  • Inverter temperature
  • Historical (daily, weekly, monthly) power curve
  • Power losses due to weather induced effects
  • Optional limitation of power output
  • Online switch for the inverter start stop