Elitech T-log B100EH Temperature and Humidity Data Logger

Humidity Data Logger

USER MANUAL

What’s Include

  • Temperature (Humidity} Data Logger x 1
  • User Manual x 1
  • Certificate of Verification x 1
  • Certificate of Quality x 1

OVERVIEW

Tlog series data loggers are used to monitor and record the temperature (humidity} for foods, pharmaceuticals, and other products during their storage and transport, and in each stage of cold chain logistics, such as refrigerated containers/trucks,  cooler bags, cooling cabinets, medical cabinets, freezers, and laboratories,

Tlog series features a USB port, LCD screen and two buttons designed to prevent accidental touches. You can view device status and parameters by button press, or customize various parameters, such as start/stop modes, multiple thresholds, storage modes, etc. You can also view automatically generated PDF report without using the Elitechlog software.
Its Tlog 8100 series are Bluetooth versions that allow operations without opening package via the Elitech app. Such as parameter configuration, data viewing, Bluetooth print, etc. that provides simple, practical, and convenient experiences.

Humidity Data Logger

USB Data Loggers

Humidity Data Logger

Bluetooth Data Loggers

Humidity Data Logger

OPERATION

1. Download & Install Software

Please download and install the free Elitechlog software (macOS and Windows) from Elitech US: www.elitechustore.com/pages/download
or Elitech UK: www.elitechonline.co.uk/software or Elitech BR: www.elitechbrasil.com.br.

2. Configure Parameters

First, connect the data logger to the computer via USS cable, wait until the U icon shows on the LCD, then Configure via Elltechlog software: If you do not need to change the default parameters (In Appendix), please click Quick Reset under Summary menu to synchronize local time before usage; If you need to change the parameters, please click the Parameter menu, enter your preferred parameters, and cllck Save P;uameter button to complete the configuration, Womlngl For first time user or ofter battery replacement:

To ovoid time or time zone errors, please make sure you click Quick Reset or Sa11e Parameter before usage to configure your loco/ time into the logger.

3. Start Logging

Press B utton:
Press and hold the left button for S seconds until the icon ► shows on the LCD, indicating the logger starts logging,

Auto Start:

Immediate Start: The logger starts logging after plugged out from the computer.

Timed Start: The logger starts counting after removed from the computer, and will automatically start logging when the set date/time comes.

Note: If the ► icon keeps flashing, it means the logger configured with start delay; it will start logging a?er the set delay time elapses. I

4. Mark Events

Double click the left button to mark current temperature and time, up to 10 groups. After events marked, the LCD wlll display l§iE , currently marked groups and !El ,

5. Stop Logging

Press B utton: Press and hold the right button for S seconds until the ■ icon shows on the LCD, indicating the logger stops logging,

Auto Stop: When the recorded points reach the maximum memory, the logger will stop automatically.
Use Software: Open Elitechlog software, click Summary menu, and Stop Lauln1 button.

Note: stop via Press Button is the default. If set as disabled, this function will be invalid, please open ElitechLog software and click Stop Logging button to stop It.

6. Download Data

Connect the data logger to your computer via USS cable, wait until the icon U shows on the LCD, then download:

Without software: A PDF report will generate automatically. Please find and open the removable storage device Tlog and save the POF report to your computer for viewing.

Vla ElltechLo1 software: The logger wlll auto-upload data to Elitechlog, then please click Export to select your desired file format to export. If data failed for auto-upload, please manually click Download and then repeat above operation.

7. Re-use the Logger

To reuse a stopped logger, please connect it to the computer, and make sure you have saved or exported the data;
Next reconfigure the logger by repeating the operation In 2. Conff1ure Parameters*. After finished, please follow 3. Start Logging to restart the logger for new logging,
Womlng! “All previous logging data inside the logger will be deleted after re-configuration os to make space for the new logging. If you forgot to sove/export data, please check and manage the logger in the History menu of ElitechLog software.

8. Repeat Start

Simply press and hold the left button to quickly restart the stopped logger without any configuration.
Please backup data before Repeat Start, by repeating 6. Download Data. Wrthout ElitechLot Software.

App Operation

1. Turn ON Bluetooth

Press and hold the left and right button for more than 5 seconds until both LED indicators flash and the icon $ flashes on the top right of the LCD,

2. Install App

Use your mobile browser to scan the QR code below or find Elitech app (the App) on your App Store to download and install it, then register a new account and log in.

Humidity Data Logger

3. Configure Parameters

(1) Click the icon ::= on the top left and select Data logger.
(2) Click the Start menu on the bottom left for parameter configuration, and then click Next on the top right for further operation.

Humidity Data Logger

(3) Press and release the right button of the logger, the app will highlight this logger. Click it to view details.
(4) Confirm the parameters and click OK on top right to complete the configuration.

Humidity Data Logger

4. View Data

1) In Nearby menu page, click llil on the top right to refresh the device list. Press the right button of the logger;,the app will highlight and top this logger. Click the logger and select Read data.

Humidity Data Logger

2) After data is read, you may view It In the graph and detailed list.Click the Icon  on the top right to stop the logger that Is logging. Under Data mend, click Cienerate Report to export your report In the desired format (PDF, Excel), click Print to print the report via the connected Bluetooth printer.

Humidity Data Logger

5. Scan Bar Code for parameter configuration and data viewing

Switch to Nearby Menu, then click the icon  on top right to scan the bar code at the back of the logger for a further operation (Configure, Read Data).

Humidity Data Logger

6. Bulk Operation

1) Switch to Nearby menu, click the sub menu Record or Stopped, and then cllck Hon the top right to refresh the device 11st.
2) Hold one logger In the 11st. and you may switch to multi-select status (IDS APP click m on the top right). Check the loggers and then click Delete, C onfigure or Read Data to handle several loggers simultaneously.

Humidity Data Logger

Status Indication

1. Buttons

Humidity Data Logger

2. LCD Screen

Humidity Data Logger

3. LCD Interface

Humidity Data Logger

4. LCD-LED Indication

Humidity Data Logger

Battery Replacement

Humidity Data Logger

Warning!

  • Please store your logger at room temperature.
  • If you use the logger for the first time, please use ElitechLog software to synchronize system time and configure parameters.
  • Do not remove the battery if the logger is recording.
  • The LCD screen will be automatically off o?er 15 seconds of inactivity. Press the button again to turn on the screen.
  • Parameter configuration on ElltechLog software wl/1 clear previously recorded data Inside the logger. Please save all history doto before you apply new configurations.
  • To ensure the humidity accuracy, please ovoid contact with unstable chem/col solvents or compounds, especlafly ovoid fang-term storage or exposure to the environments with high concentrations of ketene, acetone, ethanol, isoproponol, toluene, etc.
  • Do not use the logger for long-distance transport if the battery icon is fess thon ho/f os .
  • Before using the Bluetooth data logger, please turn on its Bluetooth function first.

Default Parameter Configurations

Humidity Data Logger

Telefono 56 4859 0213
Correo: cotiza@lacecalibracion.com
Direcci6n: Av. Adolfo L6pez Mateos #16, CP 54D50,
Tlalnepantla de Baz

Documents / Resources

Elitech T-log B100EH Temperature and Humidity Data Logger [pdf] User Manual
T-log B100EH, Tlog_100.E.H.EH.EC.EL.B.BE.BH.BEH, T-log B100EH Temperature and Humidity Data Logger, T-log B100EH, Temperature and Humidity Data Logger, and Humidity Data Logger, Humidity Data Logger, Data Logger

References