WEINTEK logotipi PLC ulanish bo'yicha qo'llanma
Weintek o'rnatilgan KODESISI
Qo'llab-quvvatlanadigan seriyalar: Weintek o'rnatilgan CODESYS HMI

HMI sozlamalari:

ParametrlarTavsiya etilganVariantlarEslatmalar
PLC turiWeintek o'rnatilgan KODESISI
PLC I/FEthernet
Onlayn simulyatorYO'Q

Qanday import qilinadi Tags:

  1. "Asosiy Vazifa" ostida POU PLC_PRG ni o'rnating.WEINTEK o'rnatilgan CODESYS HMI
  2. Qurilmalar ro'yxatiga "Symbol konfiguratsiyasi" ni qo'shing.WEINTEK o'rnatilgan CODESYS HMI - Qurilmalar
  3. PLC_RPG va uni tanlang tag ma'lumot ko'rsatiladi, loyihani tuzing.
    [qurish] -> [Kodni yaratish]WEINTEK o'rnatilgan CODESYS HMI - Diagramma 1
  4. A *.xml file loyiha katalogida yaratiladi.WEINTEK o'rnatilgan CODESYS HMI - Qurilmalar 1
  5. Qurilmalar roʻyxatiga Weintek Oʻrnatilgan CODESYS drayverini qoʻshish uchun Tizim parametrlari sozlamalarida [Yangi] tugmasini bosing va [Tag menejer].WEINTEK o'rnatilgan CODESYS HMI - menejer
  6. In Tag Menejer "Olish" tugmasini bosing tag -> Import Tagni bosing va keyin ni tanlang tag file (.xml) PLC dasturi tomonidan yaratilgan.WEINTEK o'rnatilgan CODESYS HMI - menejer 1
  7. Qachon tags muvaffaqiyatli import qilinsa, chiqish uchun [Chiqish] tugmasini bosing.WEINTEK o'rnatilgan CODESYS HMI - menejer 2

Qo'llab-quvvatlash qurilmasi turi:

Ma'lumotlar turiEasyBuilder ma'lumotlar formatiEslatma
Boolbit
Bayt16-bitli BCD, Hex, Binary, Unsigned8-bit
SInt16-bitli BCD, Hex, Binary, Signed8-bit
USInt16-bitli BCD, Hex, Binary, Unsigned8-bit
So'z16-bitli BCD, Hex, Binary, Unsigned16-bit
Int16-bitli BCD, Hex, Binary, Signed16-bit
UInt16-bitli BCD, Hex, Binary, Unsigned16-bit
DWord32-bitli BCD, Hex, Binary, Unsigned32-bit
DInt32-bitli BCD, Hex, Binary, Signed32-bit
Haqiqiy32-bitli Float32-bit
UDInt32-bitli BCD, Hex, Binary, Unsigned32-bit
LInt64-bit imzolangan64-bit
ULInt64-bitli imzosiz64-bit
LWord64-bitli imzosiz64-bit
LReal64-bitli Float64-bit
StringASCII kiritish va ko'rsatish uchun so'z massiviUzunlik = so'z

Eslatma 1: String uzunligi Codesys dasturidagi uzunlik bilan bir xil bo'lishi kerak.
Eslatma 2: EBPro V6.03.02 yoki undan keyingi versiyalari 64 bitli ma'lumotlar turini qo'llab-quvvatlaydi (faqat cMT seriyali), lekin manzil chegarasi diapazoni maksimal 48 bit ekanligini unutmang.

Ulanish diagrammasi:

Diagramma 1
Ethernet kabeli:

WEINTEK o'rnatilgan CODESYS HMI - diagrammaWEINTEK logotipi

Hujjatlar / manbalar

WEINTEK o'rnatilgan CODESYS HMI [pdf] Foydalanuvchi uchun qoʻllanma
Oʻrnatilgan CODESYS HMI, oʻrnatilgan, CODESYS HMI, HMI

Ma'lumotnomalar