UT273+ Clamp Earth Resistance Tester
P/N:110401111227X 2022.07.05 REV.1
This is the earthing resistance of grounding electrode RA. To
understanding the formulas above,
we can regard these three grounding electrodes as a triangle, then the measured resistance is:
Measured resistance = (Resistance of adjacent side 1 + Resistance of adacent side 2 – Resistance of
opposite side)+ 2
The resistances of the two reference grounding electrodes are: RB=Rl-RA,
Clamp meter Battery Calibration loop USB cable User manual Tool box
1 pc 4 pcs (1.SV AA alkaline battery) 1 pc 1 pc (data transmission) 1 pc 1 pc
responsible for other losses caused by use. The content of this user manual cannot be used as a reason for using the product for special purposes. The company reserves the right to modify the contents of the user manual. If there are changes, no
13
Documents / Resources
![]() | UNI-T UT273+ Clamp Earth Resistance Tester [pdf] User Manual UT273, UT275, UT273 Clamp Earth Resistance Tester, UT273, Clamp Earth Resistance Tester, Earth Resistance Tester, Resistance Tester, Tester |