Посібник із встановлення сенсорної панелі Zykronix Symphony XL 11.6 дюймів

Symphony XL 11.6 Inch Touch Panel

Symphony XL
11.6″ Touch Panel Quick Installation Guide

Device – Overview
Speaker Speaker Camera

Датчик освітленості

Відтінки вогнів

Microphone Hue Lights

Входить в коробку
1ea Device 1ea Mounting bracket 4ea Mounting screws
введення
To install the device you will also need one of the following electrical junction boxes or low-voltage brackets.

Standard NEMA 2-gang US electrical
розподільна коробка

Низький об'ємtage mounting ring Arlington LV2 (Bracket supplied in the box)

UK standard 2-gang electrical box

European/Italian 16204 muiltibox

Важливі вказівки з техніки безпеки
Read, understand and follow ALL safety and installation instructions included in this manual. Failure to follow the included documentation may damage the product and will void the manufacturer’s warranty. Follow ALL installation guidelines included with the product. Installation of the product in high humidity environments, in close proximity to heat sources and/or non-recommended locations WILL impede, interfere and/or damage the intended operation of the product. Only use attachments and accessories which have been specified for use by the manufacturer. The use of abrasive, liquid or solvent-based cleaning fluids WILL damage the product. Product Servicing may ONLY be completed by authorized or certified service centers & personnel. For a complete list of product servicing options, please follow instructions included in the product documentation and/or contact the original manufacturer for details.
Це обладнання було протестовано та встановлено, що воно відповідає обмеженням для цифрових пристроїв класу B відповідно до частини 15 Правил FCC.
Ці обмеження покликані забезпечити розумний захист від шкідливих перешкод у житловій установці. Це обладнання генерує, використовує та може випромінювати радіочастотну енергію і, якщо його не встановити та використовувати відповідно до інструкцій, може спричинити шкідливі перешкоди для радіозв'язку. Однак немає жодних гарантій того, що перешкоди не виникатимуть у певній установці. Якщо це обладнання спричиняє шкідливі перешкоди для радіо- чи телевізійного прийому, що можна визначити, вимкнувши та ввімкнувши обладнання, користувачеві рекомендується спробувати виправити перешкоди одним або кількома з наступних заходів:
- Переорієнтуйте або перемістіть приймальну антену. - Збільште відстань між обладнанням та приймачем. - Підключіть обладнання до розетки, що відрізняється від тієї, до якої підключений приймач. - Зверніться за допомогою до дилера або досвідченого радіо- та телевізійного спеціаліста.
Consult the dealer or contact [захищено електронною поштою] для допомоги

LAN + Power over Ethernet

USB DC Power Input

Note:Only Symphony XL equipped with hue lights.

Планування установки
The device is designed to be wall mounted in either Portrait or Landscape orientation, or on tabletop with stand.

На стіні

On the stand Part No.:89-123-1030A1F

The device requires a minimum mounting depth of 1″(2.45cm) from the wall surface to the room for cable/s. Power may be supplied by Power Over Ethernet (PoE) or by a 24V DC power supply (not included). PoE connecting must meets the IEEE 802.3af standard. Direct power connecting via a 24V DC external power supply requires a minimum current output of 1A. The device connects to the local network via a hard wired Ethernet connection. Or connecting with WiFi in the case of the units with WiFi function.

Встановлення пристрою
A. Mounting height
The recommended mounting height for the device is 57″- 65″ (145 cm -165 cm) from the finished floor to the center of the unit.

165 см / 65 "145 см / 57"

B. Landscape/Portrait mounting Device can be mounted and oriented in Portrait or Landscape.

English V1.1

Symphony XL
C. Installing the device mounting bracket
The device package includes a stainless steel mounting bracket that MUST be used for installation. Please note the mounting bracket in the box is designed for the US standard 2-gang and supplied Arlington mounting ring supplied in the box. You can order additional stainless steel mounting brackets for UK or European electrical boxes. Verify that the bracket is level before tightening the captive screws on the device. (US mounting bracket included in the box)

E. Mounting the device
1. Loosen the captive screws of the unit first. Screws should not be moved apart from the unit. Please meet the indicated line. 2. Align the mounting frame hooks with the mounting slots and gently pull the unit down the mounting bracket. Make sure the mounting hooks are properly engaged. 3. To complete the installation, tighten the 2-captive screws on the bottom part of unit, to secure the device on the mounting bracket. 4. For Portrait orientation, rotate mounting bracket and 90 degrees in counterclockwise direction before installation.

For low-voltage mounting ring-like Arlington LV2 (Supplied in the box)
Part No.:80-128-1210-21

For UK standard 2-gang electrical box
Part No.:84-128-1230-00

For standard NEMA 2-gang For European/Italian

US electrical junction box

16204 muiltibox

Part No.:80-128-1210-21 Part No.:84-128-1220-00

D. Connecting the device to power
The device is designed to be powered over the Ethernet connection (PoE) or by connecting a 24Vdc power supply (not included), but not both. If both the PoE and a 24Vdc power supply are connected, the device will draw power from the 24V DC source.
PoE Connection PoE connection requires IEEE 802.3af standard. Utilize a network switch or PoE injector that meets this standard. Connect the device using a standard T568A or T568B Ethernet cable from the network switch to the LAN/PoE jack on the back of the device.

Розпушити

Затягнути

To device
PoE Injector Network Switch

Мережевий комутатор PoE

24V DC Power Supply You can provide power locally or remotely to device by utilizing a 24V DC power supply (not included). Please note that running the wire through the wall in accordance with local codes when powering locally. If powering remotely, please ensure to use wire of adequate gauge for the length of the run. Please use approved 24V DC power supply.
Verify the polarity of the barrel connector on your power supply before connecting it to the device. The center pin of the device power connector is positive and the outer ring is negative. If the wire is extended, please ensure that the routing is in compliance with local codes.
Plug the connector into the device DC jack on the back of the device.

Line in wall

24V DC 2.1mm Coaxial Plug

Powering up the device
The device will automatically power on when power is applied. Wait for the unit to boot up. When it’s connected to a network switch by Ethernet cable, the device will acquire a network address via DHCP and automatically connect to the system.

Temperature ranges/humidity

Операційний

±0 °C to +45 °C

Storage/transport -20 °C to +70 °C

Relative humidity max. 95%(no condensation)

Tighten the 2-captive screws to secure the device to the mounting bracket.
Зняття пристрою
Using a precision Philips head screw driver to loosen the 2-captive screws on the device, then slightly pull straight up from the mounting frame to disengage the unit.
Розпушити
Setting screen orientation
On the touch panel setup screen, select Landscape or Portrait display modes. Press Start device to launch the user interface.
To change orientation: – Remove power from device. – Re-apply power to device. – Select landscape or portrait orientation.
Thank you for including the device as part of the user interface strategy for your customer. The device has been designed to provide years of trouble free operation when wired and installed properly. The device is designed for installation in low humidity indoor environments and should never be installed outdoors or in high humidity areas.
Any changes or modifications not expressly approved by the grantee of this device could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RF exposure warning This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provide with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Canada, Industry Canada (IC) Notices This device complies with Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Canada, avis d’Industry Canada (IC) Cet appareil est conforme avec Industrie Canada exemptes de licence RSS standard(s). Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne doit pas causer d’interférence et (2) cet appareil doit accepter toute interférence, notamment les interférences qui peuvent affecter son fonctionnement.

Consult the dealer or contact [захищено електронною поштою] для допомоги

English V1.1

Документи / Ресурси

Zykronix Symphony XL 11.6 Inch Touch Panel [pdf] Інструкція з встановлення
LBEE5ZZ1PJ, 2AGRR-LBEE5ZZ1PJ, 2AGRRLBEE5ZZ1PJ, Symphony XL 11.6 Inch Touch Panel, Symphony XL, 11.6 Inch Touch Panel

Залишити коментар

Ваша електронна адреса не буде опублікований.