User's Manual for Bradford White models including: FT Series Floor Standing Heating Only Boiler, FT Series, Floor Standing Heating Only Boiler, Standing Heating Only Boiler, Heating Only Boiler, Only Boiler
Apr 3, 2025 — this or any other appliance. WHAT TO DO IF YOU SMELL GAS. • Do not try to light any appliance. • Do not touch any electrical switch; do not.
File Info : application/pdf, 12 Pages, 3.01MB
DocumentDocumentUser's Manual User's Manual for Document 1511 Floor Standing, Modulating Gas, Condensing, Heating Only Boiler Model FTHF199N 199,000 BTU/h · · Propane Gas (LP) - Field-Convertible FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, death. Improper installation and/or operation will void the warranty. , property damage, or WARNING If the information in this manual is not result causing property damage, personal injury or loss of life. Do not store or use gasoline or other this or any other appliance. WHAT TO DO IF YOU SMELL GAS · Do not try to light any appliance. · Do not touch any electrical switch; do not use any phone in your building. · Immediately call your gas supplier from a nearby phone. Follow the gas supplier's instructions. · If you cannot reach your gas supplier, call Installation and service must be performed supplier. AVERTISSEMENT Assurez-vous de bien suivres les instructions données dans cette notice pour réduire au minimum le risque d'incendie ou d'explosion ou pour éviter tout dommage matériel, toute blessure ou la mort. Ne pas entreposer ni utiliser d'essence ou ni le à proximité de cet appareil ou de tout autre appareil. QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ: · Ne pas tenter d'allumer d'appareils. · Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones dans le bâtiment où vous vous trovez. · Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. · Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le sservice des incendies. L'installation et l'entretien doivent être assurés par ou par le fournisseur de gaz. H2420000- Page 2 CONTENTS Pgs - 1. Familiarizing yourself with the FT ..........................2 2. Caring For Your FT ................................................ 4 3. Start Up and Shut Down. ...................................... 4 4. Control Display and Operation .........................5-10 1. Familiarizing yourself to THE FT The FT is a floor standing, condensing and fully modulating, residential boiler. This Users Manual will guide you into the basics of operating your FT Please reference the Installation and Operation Manual for complete details ). User's Manual - The FT Series Floor Standing, Heating Only Boiler Page 3 1.1 Names of Components 7 65 4 8 9 10 11 12 13 14 15 16 17 18 19 20 # Name of Component 1 Pressure Relief Valve 2 Air Vent (air eliminator) 3 Boiler Return Connection 4 Boiler Supply Connection 5 Vent Pipe Collar 2 6 Boiler Pressure Gauge 7 Air Intake Collar 1 8 Gas Inlet Adapter 3 9 Air/ Gas Venturi 30 10 Gas Valve 29 11 BLDC Fan (Blower) 12 Low Water Cut Off 28 13 Burner High Limit Switch 27 14 Flame Detecting Sensor 26 15 Manual Power Switch (ON / OFF) 16 Heat Exchanger 25 17 Main PCB 24 18 Boiler Pump 19 Blocked Condensate Switch 20 Condensate Trap 23 21 Condensate neutralizer and Drain pump (optional equipment) 22 Drain Valve 23 Low Loss Header 24 Terminal Block 25 Overheat Temperature Sensor 26 Sight Glass 22 27 Igniter 21 28 Exhaust Pipe 29 Control Panel and Display 30 Air Pressure Sensor Page 4 2. Caring For Your FT Your FT will require very little maintenance. However, as with any fine appliance there are certain steps that should be taken to ensure continuing optimum performance. 2.1 General Care Keep the area around the FT clean and free from combustible materials, gasoline and other flammable liquids and vapors. The FT must be completely isolated and protected from any source of corrosive chemical fumes such as trichlorethylene, perchlorethylene, chlorine, etc. Keep bottom and top openings on the boiler free for proper ventilation of interior components. Do not obstruct or block a free flow of air to the boiler to ensure proper ventilation. If desired, clean the jacket surfaces with a damp cloth and mild detergent. Do not use flammable cleaning materials. If sidewall vented, keep the vent terminal clear of obstructions -- do not allow snow to cover the vent terminal. Clean the intake screen often, and then develop an appropriate maintenance schedule. 2.2 Annual Inspection of Flue and Vents Visually inspect the vent pipe once a year. Should any deterioration exist, have the affected parts replaced by a qualified service person. 2.3 In the Event of a Power Failure The FT can not be operated during an electrical power outage. If there is an extended power outage with danger from freezing, then the FT (and all other water systems) should be drained completely. When draining the boiler, turn off main electrical disconnect switch. When placing back in service, refer to Section 3 of this Manual for instruction. All draining and filling must only be done by a qualified service person. 2.4 Full Service Every Year In addition to the annual visual inspections, a qualified service agency should conduct a detailed inspection of all flue product carrying areas of the boiler and its venting system. 3. Shut Down and Restart 3.1 To Start the FT If drained, please refer to the Install and Operating Manual to ensure that the complete `Setup' procedure has been followed before starting this boiler. A complete `Setup' must be performed by a qualified service person. 3.2 Shutting Down the FT 1. Turn off the main electrical disconnect switch. 2. Close all manual gas valves. 3. If freezing is anticipated, drain the FT and be sure to also protect building piping from freezing. All water must be removed from heat exchanger and condensate trap or else damage from freezing may occur. Please refer to the Install and Operating Manual. This step to be performed by a qualified service person. User's Manual - The FT Series Floor Standing, Heating Only Boiler 4. The ControlCDoisnptrloayl DainsdplOaypeanradtiOonperation The Control Display Page 5 B C E Status Light A D (constant green when operating normally) The Control Display has a Control Dial (E), 4 buttons (A, B, C, D), and a Liquid Crystal Display (with 72 back-lit segments). This section of this manual gives instruction on how to navigate into the many functions of the FT and to change temperature set points, set system variables and controller parameters. Buttons PRESS (Tap) Functionality PRESS and HOLD (5 seconds) A Display Power Turns Control Display ON/OFF B Modes Tap to return to menu (If Display Power was On ) Status Display Mode (If Display Power was Off ) Installer Mode C Heating Water CH set-point change mode (Maxium 82°C(180°F)) D Time / Date Set No Change To SET: Year/Month/Week/Day/Time/Min E Scroll / Select Menu select or value up(+)/down(-) or setting dial. · Temperature Specifications Operating ambient Temperature Range : -10 to 60°C. Operating Relative Humidity up to: 90% at 40°C. Shipping & Storage Temperature Range of : -20 to 80°C. water. Immediately call a qualified service technician been under water. Page 6 4. The Control Display and Operation (continued) LCD Overview Symbol Name Description Service Reminder mode Service Reminder mode indication Outside Temperature Mode Anti-freeze mode Storage mode Outside Temp setting indication Anti-freeze mode indication Storage mode indication Information mode Communication state Time setting mode Information mode indication Communication state indication Time /Dispaly/Install mode indication Fan operating mode Fan operating mode indication Flame signal CH pump mode Storage pump mode Internal boiler pump Celsius mode Fahrenheit mode Heat demand mode Flame Signal indication CH pump mode indication Storage pump mode indication Internal Boiler pump mode indication Indicated as Celsius temperature Indicated as Fahrenheit temperature Heat demand mode indication DAY mode Cascade System connecting mode Cascade System operating mode Current day mode indication Cascade System connecting mode indication Cascade System operating mode indication The LCD will illuminate when a user action is detected (a button is pressed) and will turn back off after 20 seconds. User's Manual - The FT Series Floor Standing, Heating Only Boiler 5.3 Operating Mode Operating Mode After the Power is turned on, and/or the Control Display is turned on , the Control Display will go through a `Start Up' checklist and briefly show a sequence of diagnostic codes before entering into the `Operating Mode. It will then display the following information. Page 7 B C E A D Indicate Current Operating Temperature Set-Point Indicator If the Fan is operating If a flame is detected Celsius or Fahrenheit or Date and Time indicator If Outside Temperature Sensor is operating If there is a Demand for Central Heat (CH) If CH pump state is operating If Internal recirculation pump is operating If Communication state is activated The Control Display can operate through user and service modes that have specific LCD output and dedicated controls: · Set-point change mode · Lock mode · Error mode · Status display mode · Outside Temperature mode · Installer mode * Control Display will not allow changing of button in case of lock mode activated. Page 8 5.4 Setting the Clock B C E A D The P-950EH Control Display does NOT have a daily timer or programmable thermostat. Setting the Clock a. Press and hold the `Clock button' for about 5 seconds. Set the `Year' by turning the dial E. And then, press the dial E to Save. b. Set the `MON' (Month) by turning the dial E to the desired month number. Then press the dial E to Save. c. Set the `DATE' (1-31, Day of the Month) by turning the dial E. Then press the dial E to Save. d. Set the `HOUR' (1-24, Hour of the Day) by turning the dial E. Then press the dial E to Save. e. Set the `MIN' (1-60, Minute of the Hour) by turning the dial E. Then press the dial E to Save. f. Set the `Day' (Sun - Sat) by turning the dial E. Then press the dial E to Save. To Exit at any time, tap the button. User's Manual - The FT Series Floor Standing, Heating Only Boiler 5.5 CH Set Point Change Mode CH Set point Change Mode Page 9 B C E A D To change CH Setpoint, press the C button. The CH Icon and current CH Setpoint will flash. Turn the E dial clockwise to increase, and counterclockwise to decrease CH setpoint, until desired temperature is reached. Press E dial to save changes and to Exit. Indicate Current CH Temperature Set-Point Celsius or Fahrenheit If Communication state is activated If flame is detected Date and Time indicator If CH pump is operating If there currently a Demand for Central Heat (CH) Indicator or Default CH set-point is 140°F (60°C) CH set-point range is 130°F ~180°F (54°C ~ 82°C) Page 10 5.6 Status Display Mode To view any Status Parameter, Press and Hold Button B to get into the Status Display Mode. Rotate Dial E until you find the Parameter that you wish to view. Tap Dial E to enter that Parameter as required. Dial E to save and to exit the Status Information Menu. To go back to the Operation Screen Press button B. B C E A D NOTE: For Cascading Installations, please refer to document 1349 `Cascading the FT Series Boiler', available online. Digital Display O: ot A: In Status Display Parameter Outdoor temperature 0-10 V display b: tt CH target temperature in cascade system C: It d: Fr CH return water temperature FAN speed ( rpm) Description Current outdoor sensor temperature Current voltage of (0-10V input) Current CH target temperature or Current System target temperature in a cascade system Current CH return water temperature Current FAN speed ( RPM) E: oP F: Eh CH supply temperature (Operating temperature) Current heating temperature Exhaust gas temperature Current exhaust gas temperature H: dH Indirect DHW tank temperature * If temperature sensor is not connected then it will display with 0°F (0°C). Current DHW tank temperature I: oH 1: PH 2: rh L: rt 3: rH 4: It 5: IH Overheat water temperature Burner Operation Time Time for supply power Time for burner operation Time for burner operation Cycle for ignition Cycle for ignition Current Overheat water temperature Unit : 1000hour Unit : 1hour L: rt on display on sub menu Unit : 1,000hour Cycle : 10 times the displayed unit Cycle : 10,000 times the displayed unit SELF Percentage of self units running. Percentage of self units running. M: ALL CC Capacity for all operating cascade units Percentage of all cascade units running. This screen shows the overal cascade power output. The range of this value of boilers communicating with theMaster x 100. For example, if 8 boilers are connected and communicating, the maximum cascade power is 800%. Range: 0-100% F1 F 19 N: St Capacity for individual boilers System Temperature (cascade mode) * If system temperature sensor is not connected then it will display with 0°F (0°C). Percentage of each cascade units running. Ex. F1, F2, .... Current System Temperature (cascade mode) User's Manual - The FT Series Floor Standing, Heating Only Boiler Notes: Page 11 User's Manual - The FT Series Floor Standing, Heating Only Boiler Notes: H2420000- Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Customer Service and Product Support: 800.900.9276 · Fax 800.559.1583 20 Industrial Way, Rochester, NH, USA 03867 21-05 Document 1511PDFsharp 6.1.1 (Original: Adobe PDF Library 15.0)