Leviton GFSW1-W

Leviton GFSW1-W Smartlockpro GFCI Receptacle & Switch Instruction Manual

Model: GFSW1-W

1. Вступ

This manual provides essential information for the safe installation, operation, and maintenance of your Leviton GFSW1-W Smartlockpro Tamper-Resistant Combo GFCI Receptacle & Switch. This device combines a ground fault circuit interrupter (GFCI) receptacle with a standard switch, offering enhanced electrical safety and convenience in a single unit. Please read these instructions thoroughly before beginning installation or use.

2. Інформація про безпеку

WARNING: RISK OF ELECTRIC SHOCK OR FIRE. IMPROPER INSTALLATION OR USE MAY RESULT IN SERIOUS INJURY OR DEATH.

  • Always turn off power at the circuit breaker or fuse box before installing or servicing this device.
  • Встановлення має виконувати кваліфікований електрик відповідно до всіх національних та місцевих електротехнічних норм.
  • Do not use this device with aluminum wiring. Use only with copper or copper-clad wire.
  • Переконайтеся, що всі з'єднання проводів надійно закріплені та належним чином ізольовані.
  • This device is designed for indoor use in dry locations unless otherwise specified.

3. Особливості продукту

  • Функція самотестування: Provides continuous ground fault protection by automatically testing the GFCI. It detects and trips on actual ground faults even during self-testing.
  • Initial Power-Up Test: Tests the GFCI within 3 seconds of initial power-up.
  • Auto-Monitoring: Exceeds UL requirements by adapting and shifting to more frequent testing if a potential problem is detected.
  • Protection Status Indicator: An LED light provides simple, intuitive feedback on power and protection status, including indication of line/load reversal.
  • Patented Bridge Contact: Ensures no power is delivered to the receptacle face if improperly wired (line-load reversed).
  • Enhanced Immunity: Improved immunity to high-frequency noise reduces nuisance tripping.
  • Surge Resistance: Advanced electronics provide superior resistance to electrical surges and over-voltagес.
  • Lockout Action: Patented lockout action prevents reset if the GFCI is damaged and cannot respond to a ground fault.
  • TampЕр-стійкий контейнер: Designed to prevent insertion of foreign objects into the receptacle openings.
  • Міцна конструкція: Features an impact-resistant thermoplastic cover and polycarbonate body.

4. Технічні характеристики

АтрибутЗначення
МодельGFSW1-W
томtage125 вольт
Amperage (Receptacle)15 Amps
Рейтинг перемикання15 Amp - 120 VAC
Конфігурація NEMA5-15Р
КолірБілий
матеріалThermoplastic face, Polycarbonate body
Розміри виробу (Д х Ш)1.7 дюйма завдовжки x 1.13 дюймів завширшки
Робоча температура-35°C до 66°C
Agency StandardsUL Standard 943 Class A (GFCI), UL 498 (Receptacles), CSA Certified, NOM Certified

5. Встановлення (налаштування)

ВАЖЛИВО: Turn OFF power at the circuit breaker or fuse box before wiring. Failure to do so may result in serious injury or death.

  1. Підготуйте електропроводку: Carefully remove the existing device from the wall box. Identify the LINE (incoming power) and LOAD (downstream protection) wires. If you are unsure, consult a qualified electrician.
  2. Підключіть дроти:
    • Connect the LINE hot wire to the brass LINE terminal.
    • Connect the LINE neutral wire to the silver LINE terminal.
    • If protecting downstream receptacles, connect the LOAD hot wire to the brass LOAD terminal.
    • If protecting downstream receptacles, connect the LOAD neutral wire to the silver LOAD terminal.
    • Connect the ground wire to the green ground screw.
    • Переконайтеся, що всі з’єднання міцні та надійні.
  3. Монтаж пристрою: Carefully fold the wires into the wall box. Mount the GFCI receptacle and switch into the wall box using the provided screws.
  4. Встановлення настінної панелі: Attach the wallplate (not included) over the device.
  5. Відновлення живлення: Turn ON power at the circuit breaker or fuse box.
  6. Перевірте GFCI: Perform the initial test as described in the "Operation" section to ensure proper functioning.
Leviton GFSW1-W Smartlockpro GFCI Receptacle and Switch installed in a white tiled wall.

Image: The Leviton GFSW1-W Smartlockpro GFCI Receptacle and Switch, white in color, shown installed on a white tiled wall. It features a rocker switch at the top, and below it, a GFCI receptacle with "RESET" and "TEST" buttons, and a small LED indicator light.

6. Операція

The Leviton GFSW1-W combines a standard light switch with a GFCI-protected receptacle.

  • Функція перемикача: The top rocker switch operates connected lighting or other loads. Press the top to turn ON, press the bottom to turn OFF.
  • GFCI Receptacle: The lower portion provides a 15 Amp, 125 Volt tamper-resistant outlet with ground fault protection.
  • Testing the GFCI:
    1. Вилка алamp or other device into the GFCI receptacle and turn it ON.
    2. Натисніть кнопку «ТЕСТ». GFCI має спрацювати, і lamp/device should turn OFF. The LED indicator may change color or turn off.
    3. Натисніть кнопку «СКИДАННЯ». GFCI має скинутися, іamp/device should turn ON. The LED indicator should return to its normal operating state (e.g., green).
    4. If the GFCI does not trip or reset as described, it may be improperly wired or defective. Do not use and consult a qualified electrician.
  • Скидання GFCI: If the GFCI trips (power is interrupted), press the "RESET" button firmly. If it does not reset, check for a ground fault or consult the troubleshooting section.

7. Технічне обслуговування

Regular testing of your GFCI device is crucial to ensure continued protection against ground faults. Leviton recommends testing your GFCI monthly.

  • Follow the "Testing the GFCI" procedure outlined in the Operation section at least once a month.
  • If the GFCI fails to trip or reset during testing, it must be replaced immediately.
  • Keep the device and wallplate clean. Use a soft, damp cloth for cleaning; avoid abrasive cleaners or solvents.

8. Вирішення проблем

проблемаМожлива причинаРішення
GFCI не скинеться.
  • Немає живлення на GFCI.
  • GFCI is improperly wired (LINE/LOAD reversed).
  • У колі живлення або підключеному приладі є замикання на землю.
  • GFCI is defective.
  • Перевірте вимикач.
  • Перевірте з'єднання проводів.
  • Unplug all appliances and try to reset. If it resets, plug in appliances one by one to identify the faulty one.
  • Замініть захисний вимикач (GFCI).
GFCI часто спрацьовує.
  • Постійне замикання на землю.
  • Перевантаження на ланцюзі.
  • Moisture or damage to connected appliances/cords.
  • Inspect wiring and appliances for faults.
  • Зменште кількість пристроїв у колі.
  • Inspect and replace damaged items.
Switch does not operate.
  • Немає живлення пристрою.
  • Incorrect wiring of the switch.
  • Несправний перемикач.
  • Перевірте вимикач.
  • Verify switch wiring.
  • Замініть пристрій.

9. Гарантія та підтримка

Limited Two-Year Product Warranty: Leviton warrants this product to be free from defects in material and workmanship under normal use and service for a period of two years from the date of original purchase. For complete warranty details, please refer to the documentation included with your product or visit the official Leviton webсайт.

Підтримка клієнтів: If you require assistance with installation, troubleshooting, or have questions about your Leviton GFSW1-W device, please contact Leviton Customer Service. Contact information can typically be found on the product packaging or the official Leviton webсайт (www.leviton.com).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.