Trimble-logo

Trimble GS200A Wireless Load Cell

Trimble-GS200A-Wireless-Load-Cell-product

Wireless Load Cell 

Features

  • Standard single part line pull sizes ranging from 5,000 to 600,000 lb.
  • All stainless frame and hardware
  • Heavy duty construction from 17-4PH1150 stainless steel (17-4PH1025 on models 250,000lb and up)
  • Accuracy of +/-1% on a single part of line
  • Option available with CSA Class 1 division 1 certification.
  • Ships calibrated
  • Stock and custom bushings for most applications.
  • Radio range with line of sight: 4000 ft. (1300 m)
  • Operates with one ‘D’ cell battery lithium 3.6V or alkaline 1.5V.
  • 2 years battery life for typical applications
  • ISM license free radio: wavelength and modulation optimized for radio communication in industrial environments.
  • Temperature range: -40°C to 85°C (-40°F to 185°F)
  • Temperature compensated
  • Potted electronics for increased water protection
  • Rugged field-replaceable antenna (TA011)
  • Custom sizes on request
  • 2-year warranty
  • Designed with a safety factor of 5:1 on the safe working load.
  • All load bearing bodies have been tested by ultrasounds, die-penetrant and proof loaded to 150% of capacity.

Applications

Designed for all applications in the lifting industry, including offshore, that do not require the load cell to be submerged (due to radio communications). Installation above a ball, odd parted on the block, or even parted on the boom tip.

Trimble-GS200A-Wireless-Load-Cell- (1)

General Description

The load cell is installed in-line with the wire-rope. This load creates minute deformations of the load cell and electronics convert it into a load value, which is transmitted to the receiving unit. The transmitter box mounted to the load cell houses the battery, radio transmitter, and load converter.Trimble-GS200A-Wireless-Load-Cell- (2)

Ordering Information

ModelDescription
GCxxx-V2Load Cell. The three ‘X’ digits are working load limit (WLL) in thousands of pounds. For example, GC060-V2 is for a 60,000-lb WLL or 27215-kg WLL. Load cell is FCC approved.
GCxxx-CSA-V2Load cell certified Class 1 Division 1, suitable for Div 1 and Div 2
GCxxx-xx-CE-V2Load cell CE certified, with radio frequency suitable for Europe, most of Asia and Middle East
LC6XX-XXAppropriate adapter plate kit for load cell (see table page 6).
LC6XX-5XAppropriate 90° adapter plate kit for load cell (see table page 8).

Examples:
GC170-V2: is a 170,000 lbs load cell with FCC certification.

Specifications

ParameterTest ConditionMinTypMaxUnit
Load Tension Measurement
Resolution+/-0.0250.0750.2% of SWL
Accuracy+/-0.512% of SWL
Radio Power
GCXXX-V20.0054W
7dBm
Radio Frequency
North American versionGCXXX-V2903927MHz
European versionGCXXX-CE-V2868870MHz
Battery life
‘D’ cell lithium ‘D’ cell alkaline12824122816Month Month

Absolute Maximum Ratings

ParameterTest ConditionMinTypeMaxUnit
Ambient temperature rangeOperating-40-40+60+140ºC ºF
Storage-40-40+85+185ºCºF

Certifications

  • FCC/IC/CE certification : FCC Part 15 Subpart C 15.247,15.205, 15.207 & 15.209
  • ETSI EN 300 220 (AA)
  • EMI/C – EN 61000-4-3, EN 301 489-1 – Clause 8.2
  • CSA Certificate Number – 80130757
  • CSA C22.2 No. 60079-0:19, 60079-11:14 (R2018), 61010-1-12, Update 1&2, Amd1:2018 UL 60079-0-2020, UL 60079-11-2018, UL 61010-1-2018
  • Class I, Division 1, Group A, B, C & D T4
  • Ex ia IIC T4 Ga
  • Class I, Zone 0, A Ex ia IIC T4 Ga
  • Ambient Temperature: -20°C to 40°C.

WARNING: Only use Tadiran TL-5930 3.6V or Saft LS33600 cell 3.6V text.

Specifications by Model and Options

 Load Cell model

Max loadWeight
(lb)(kg)(lb)(kg)
GC005-V25000227052.3
GC012-V21200054409.004.08
GC018-V218000816010.004.54
GC035-V2350001588016.007.26
GC060-V2600002721529.0013.15
GC100-V21000004536046.0020.87
GC170-V21700007700094.0042.64
GC250-V2250000113400106.0048.08
GC300-V2300000136100122.0055.34
GC400-V2400000181000199.0090.26
GC600-V2600000227000288.00130.63

Materials
The load cell and hardware are made of stainless steel, AISI 304 and 17-4PH1150 (up to GC170) or 17-4PH1025 (GC250 and over). The bushings are made from 1045 steel.

Dimensions

Dimensions (Not to Scale)

 

Trimble-GS200A-Wireless-Load-Cell- (3)

Load CellDIMENSIONS
  A  B  C  D  E  F  G  H φJ for Pin φK for Pin
GC005-V2(in)3.936.208.301.142.950.653.006.127/87/8
(mm)99.8157.5210.828.974.916.576.2155.42222
GC012-V2(in)3.937.5010.401.792.950.953.176.281-1/41-1/4
(mm)99.8190.5264.245.474.924.180.4159.63232
GC018-V2(in)3.937.5010.401.792.951.203.446.551-3/81-3/8
(mm)99.8190.5264.245.474.930.587.2166.43535
GC035-V2(in)2.868.7513.152.793.951.203.426.542-1/41-5/8
(mm)72.5222.3334.070.9100.330.586.7166.05741
GC060-V2(in)2.869.0014.583.324.951.653.927.042-1/22-1/2
(mm)72.5228.6370.3384.3125.741.999.5178.76363
GC100-V2(in)2.8611.6018.904.376.002.004.227.3433
(mm)72.5294.6480.1111.0152.450.8107.1186.37676
GC170-V2(in)2.8613.0021.205.077.003.004.988.103-1/83-1/8
(mm)72.5330.2538.5128.8177.876.2126.5205.78080
GC250-V2(in)2.8614.5023.565.827.102.884.767.873-3/43-3/4
(mm)72.5368.3598.4147.9180.373.2120.8200.09595
GC300-V2(in)2.8614.0023.6885.577.443.385.048.154-1/44-1/4
(mm)72.5355.6601.5141.5189.085.7127.9207.1108108
GC400-V2(in)2.8617.5028.787.328.673.885.328.4455
(mm)72.5444.5731.0186.0220.298.4135.1214.3127127
GC600-V2(in)2.8619.0032.088.0710.703.885.448.555-1/45-1/4
(mm)72.5482.6814.8205.0271.898.4138.0217.2133133

Standard Bushings

 Load Cell BushingADAPTS TO PIN f
(in)(mm)
GC012-V2PC401125
GC018-V2PC1181-1/432
GC035-V2PC4241-1/238
PC4251-5/841
PC4261-3/444
PC4271-7/848
PC428250
PC429*1-1/432
GC060-V2PC1142-1/457
PC115251
GC100-V2PC4162-1/264
PC4192-3/470
PC431251
GC170-V2PC4482-1/457
PC4492-1/264
GC250-V2PC4432-1/457
PC4442-3/470
PC4453-1/483
GC300-V2PC4463-3/496
PC4474-1/8105
GC400-V2PC4534-1/8105
PC4544-1/4108
PC4554-3/4121
GC600-V2PC4565127

Standard included bushings are in bold and depends on adapter plate kit when load cell and adapter plate kit are ordered together.  Fits in the 1-5/8 hole, the other bushings for the GC035 fit in the 2-1/4 hole.

Adapter Plate Kits  (designed with a 5:1 safety factor)

Trimble-GS200A-Wireless-Load-Cell- (4)

LoadKit #PlatePin NumberPinNut WasherNutCotter PinWasherBushing*WLLb
CellITM 1ITM 2ITM 3ITM 4ITM 5ITM 6QtyITM 7(kg)
GC012-V2LC612-01PC612-011PC501QW912QV930QP003SQW9016PC40112,000(5454)
2PC502QW912QV930QP003SQW9026
GC018-V2LC618-01PC618-011PC502QW912QV930QP003SQW9024PC11818,000(8181)
2PC503QW912QV930QP003SQW9064
GC035-V2LC635-01PC635-011PC502QW912QV930QP003SQW9022PC42935,000(15909)
2PC502QW912QV930QP003SQW9022PC423
LC635-02PC635-021PC506QW902QV950QP003SQW903635,000(15909)
2PC504QW907QV951QP004SQW9046PC428
LC635-03PC635-031PC506QW902QV950QP003SQW903635,000(15909)
2PC505QW902QV950QP003SQW9036PC424
LC635-04PC635-041PC506QW902QV950QP003SQW9036PC42435,000(15909)
2PC505QW902QV950QP003SQW9036PC424
LC635-06PC635-02(w/ PC432)1PC524QW902QV951QP003SQW9086PC42735,000(15909)
2PC506QW903QV950QP003SQW9036
LC635-07PC635-02 (w/ PC417)1PC519QW902QV951QP004SQW9086PC42635,000(15909)
2PC506QW903QV950QP003SQW9036
LC635-09PC635-051PC522QW903QV951QP004SQW904B435,000(15909)
2PC506QW903QV950QP003SQW9034
GC060-V2LC660-01PC660-011PC506QW902QV950QP003SQW9032PC10860,000(27272)
2PC506QW902QV950QP003SQW9032PC108
LC660-02PC660-021PC508QW903QV951QP004SQW904B4PC11460,000(27272)
2PC507QW903QV951QP004SQW9044PC115
LC660-03PC660-031PC508QW903QV951QP004SQW904B4PC11460,000(27272)
2PC507QW903QV951QP004SQW9044PC115
LC660-04PC660-041PC508QW903QV951QP004SQW904B4PC11460,000(27272)
2PC507QW903QV951QP004SQW9044PC115
LC660-05PC660-051PC509QW904QV952QP004SQW904C1060,000(27272)
2PC509QW904QV952QP004SQW904C10
LC660-06PC660-061PC509QW904QV952QP004SQW904C1060,000(27272)
2PC509QW904QV952QP004SQW904C10

Bushings not included. Required bushings included with load when load cell and adapter plate are ordered together.

Adapter Plate Geometry

    Load Cell    Kit #   Pin 1 Diameter   Pin 2 Diameter    C    D    L    X    Y    Z
GC012-V2LC612-01(in)1.001.254.232.003.750.503.006.75
(mm)25.431.8107.450.895.312.776.2171.5
GC018-V2LC618-01(in)1.251.384.231.754.250.633.007.35
(mm)31.834.9107.444.5108.015.976.2186.7
GC035-V2LC635-01(in)1.251.254.231.504.250.754.008.25
(mm)31.831.8107.438.1108.019.1101.6209.6
LC635-02(in)1.632.005.842.507.250.754.0011.50
(mm)41.350.8148.363.5184.219.1101.6292.1
LC635-03(in)1.631.505.532.5010.250.754.0014.50
(mm)41.338.1140.563.5260.419.1101.6368.3
LC635-04(in)1.631.505.532.5036.000.754.0040.25
(mm)41.338.1140.563.5914.419.1101.61022.4
LC635-06(in)1.881.635.842.507.250.754.008.25
(mm)47.641.3148.363.5184.219.1101.6209.6
LC635-07(in)1.751.635.842.507.250.754.008.25
(mm)44.541.3148.363.5184.219.1101.6209.6
LC635-09(in)2.251.635.842.506.000.754.0010.10
(mm)57.241.3148.363.5152.419.1101.6256.5
GC060-V2LC660-01(in)1.631.635.532.005.251.005.0010.25
(mm)41.341.3140.550.8133.425.4127.0260.4
LC660-02(in)2.252.006.342.505.251.005.0010.50
(mm)57.250.8161.063.5133.425.4127.0266.7
LC660-03(in)2.252.006.342.5011.251.005.0016.50
(mm)57.250.8161.063.5285.825.4127.0419.1
LC660-04(in)2.252.006.342.5024.001.005.0029.25
(mm)57.250.8161.063.5609.625.4127.0743.0
LC660-05(in)2.502.508.093.007.251.005.0012.50
(mm)63.563.5205.576.2184.225.4127.0317.5
LC660-06(in)2.502.508.093.0011.251.005.0016.50
(mm)63.563.5205.576.2285.825.4127.0419.1

Adapter Plate Kits

Trimble-GS200A-Wireless-Load-Cell- (5)

   Load Cell   Kit #  Adapter Bar  Pin Number   Pin  Nut Washer   Nut  Cotter Pin   Washer   Bushing  WLLlb
ITM 1ITM 2ITM 3ITM 4ITM 5ITM 6QtyITM 7(kg)
GC035-V2LC635-51PC635-511PC531QV954QP00335,000(15909)
2PC530QV954QP003PC405
GC060-V2LC660-51PC660-511PC507QW903QV951QP004SQW9044PC10860,000(27272)
   `   Kit #  Pin 1 Diameter  Pin 2 Diameter   C   D   L   X   Z
GC035-V2LC635-51(in)1.631.503.931.5024.000.7528.00
(mm)41.338.199.838.1609.619.1711.2
GC060-V2LC660-51(in)2.003.00*6.342.5045.001.0050.50
(mm)50.876.2*161.063.51143.025.41282.7

Pin not included with Adapter kit

  • PMN: GC018-V2, GC035-V2
  • HVIN: MB103-00-SD-A

FCC Compliance Statement (USA)

FCC ID: S9E-GS200A
Compliance Statements: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including, an interference that may cause undesired operation.

Caution Statements:

  • Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

Industry Canada (IC) Compliance Statement

IC: 5817A-GS000A

Compliance Statements: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.,
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Caution Statements:

  • This equipment complies with radio frequency exposure limits set forth by Industry Cananda for an uncontrolled environment.
  • This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders.

Information to the User

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FAQ

Q: What battery types are recommended for the load cell?
A: Only use Tadiran TL-5930 3.6V or Saft LS33600 cell 3.6V as per the warning in the manual.

Documents / Resources

Trimble GS200A Wireless Load Cell [pdf] Owner's Manual
GS200A, S9E-GS200A, S9EGS200A, GS200A Wireless Load Cell, Wireless Load Cell, Load Cell

References

Leave a comment

Your email address will not be published. Required fields are marked *