Trimble GS200A Wireless Load Cell Owner’s Manual

Trimble-logo

Trimble GS200A Wireless Load Cell

Trimble-GS200A-Wireless-Load-Cell-product

Wireless Load Cell 

Features

  • Standard single part line pull sizes ranging from 5,000 to 600,000 lb.
  • All stainless frame and hardware
  • Heavy duty construction from 17-4PH1150 stainless steel (17-4PH1025 on models 250,000lb and up)
  • Accuracy of +/-1% on a single part of line
  • Option available with CSA Class 1 division 1 certification.
  • Ships calibrated
  • Stock and custom bushings for most applications.
  • Radio range with line of sight: 4000 ft. (1300 m)
  • Operates with one ‘D’ cell battery lithium 3.6V or alkaline 1.5V.
  • 2 years battery life for typical applications
  • ISM license free radio: wavelength and modulation optimized for radio communication in industrial environments.
  • Temperature range: -40°C to 85°C (-40°F to 185°F)
  • Temperature compensated
  • Potted electronics for increased water protection
  • Rugged field-replaceable antenna (TA011)
  • Custom sizes on request
  • 2-year warranty
  • Designed with a safety factor of 5:1 on the safe working load.
  • All load bearing bodies have been tested by ultrasounds, die-penetrant and proof loaded to 150% of capacity.

Applications

Designed for all applications in the lifting industry, including offshore, that do not require the load cell to be submerged (due to radio communications). Installation above a ball, odd parted on the block, or even parted on the boom tip.

Trimble-GS200A-Wireless-Load-Cell- (1)

General Description

The load cell is installed in-line with the wire-rope. This load creates minute deformations of the load cell and electronics convert it into a load value, which is transmitted to the receiving unit. The transmitter box mounted to the load cell houses the battery, radio transmitter, and load converter.Trimble-GS200A-Wireless-Load-Cell- (2)

Ordering Information

Model Description
GCxxx-V2 Load Cell. The three ‘X’ digits are working load limit (WLL) in thousands of pounds. For example, GC060-V2 is for a 60,000-lb WLL or 27215-kg WLL. Load cell is FCC approved.
GCxxx-CSA-V2 Load cell certified Class 1 Division 1, suitable for Div 1 and Div 2
GCxxx-xx-CE-V2 Load cell CE certified, with radio frequency suitable for Europe, most of Asia and Middle East
LC6XX-XX Appropriate adapter plate kit for load cell (see table page 6).
LC6XX-5X Appropriate 90° adapter plate kit for load cell (see table page 8).

Examples:
GC170-V2: is a 170,000 lbs load cell with FCC certification.

Specifications

Parameter Test Condition Min Typ Max Unit
Load Tension Measurement
Resolution +/- 0.025 0.075 0.2 % of SWL
Accuracy +/- 0.5 1 2 % of SWL
Radio Power
GCXXX-V2 0.0054 W
7 dBm
Radio Frequency
North American version GCXXX-V2 903 927 MHz
European version GCXXX-CE-V2 868 870 MHz
Battery life
‘D’ cell lithium ‘D’ cell alkaline 128 2412 2816 Month Month

Absolute Maximum Ratings

Parameter Test Condition Min Type Max Unit
Ambient temperature range Operating -40-40 +60+140 ºC ºF
Storage -40-40 +85+185 ºCºF

Certifications

  • FCC/IC/CE certification : FCC Part 15 Subpart C 15.247,15.205, 15.207 & 15.209
  • ETSI EN 300 220 (AA)
  • EMI/C – EN 61000-4-3, EN 301 489-1 – Clause 8.2
  • CSA Certificate Number – 80130757
  • CSA C22.2 No. 60079-0:19, 60079-11:14 (R2018), 61010-1-12, Update 1&2, Amd1:2018 UL 60079-0-2020, UL 60079-11-2018, UL 61010-1-2018
  • Class I, Division 1, Group A, B, C & D T4
  • Ex ia IIC T4 Ga
  • Class I, Zone 0, A Ex ia IIC T4 Ga
  • Ambient Temperature: -20°C to 40°C.

WARNING: Only use Tadiran TL-5930 3.6V or Saft LS33600 cell 3.6V text.

Specifications by Model and Options

 Load Cell model

Max load Weight
(lb) (kg) (lb) (kg)
GC005-V2 5000 2270 5 2.3
GC012-V2 12000 5440 9.00 4.08
GC018-V2 18000 8160 10.00 4.54
GC035-V2 35000 15880 16.00 7.26
GC060-V2 60000 27215 29.00 13.15
GC100-V2 100000 45360 46.00 20.87
GC170-V2 170000 77000 94.00 42.64
GC250-V2 250000 113400 106.00 48.08
GC300-V2 300000 136100 122.00 55.34
GC400-V2 400000 181000 199.00 90.26
GC600-V2 600000 227000 288.00 130.63

Materials
The load cell and hardware are made of stainless steel, AISI 304 and 17-4PH1150 (up to GC170) or 17-4PH1025 (GC250 and over). The bushings are made from 1045 steel.

Dimensions

Dimensions (Not to Scale)

 

Trimble-GS200A-Wireless-Load-Cell- (3)

Load Cell DIMENSIONS
  A   B   C   D   E   F   G   H  φJ for Pin  φK for Pin
GC005-V2 (in) 3.93 6.20 8.30 1.14 2.95 0.65 3.00 6.12 7/8 7/8
(mm) 99.8 157.5 210.8 28.9 74.9 16.5 76.2 155.4 22 22
GC012-V2 (in) 3.93 7.50 10.40 1.79 2.95 0.95 3.17 6.28 1-1/4 1-1/4
(mm) 99.8 190.5 264.2 45.4 74.9 24.1 80.4 159.6 32 32
GC018-V2 (in) 3.93 7.50 10.40 1.79 2.95 1.20 3.44 6.55 1-3/8 1-3/8
(mm) 99.8 190.5 264.2 45.4 74.9 30.5 87.2 166.4 35 35
GC035-V2 (in) 2.86 8.75 13.15 2.79 3.95 1.20 3.42 6.54 2-1/4 1-5/8
(mm) 72.5 222.3 334.0 70.9 100.3 30.5 86.7 166.0 57 41
GC060-V2 (in) 2.86 9.00 14.58 3.32 4.95 1.65 3.92 7.04 2-1/2 2-1/2
(mm) 72.5 228.6 370.33 84.3 125.7 41.9 99.5 178.7 63 63
GC100-V2 (in) 2.86 11.60 18.90 4.37 6.00 2.00 4.22 7.34 3 3
(mm) 72.5 294.6 480.1 111.0 152.4 50.8 107.1 186.3 76 76
GC170-V2 (in) 2.86 13.00 21.20 5.07 7.00 3.00 4.98 8.10 3-1/8 3-1/8
(mm) 72.5 330.2 538.5 128.8 177.8 76.2 126.5 205.7 80 80
GC250-V2 (in) 2.86 14.50 23.56 5.82 7.10 2.88 4.76 7.87 3-3/4 3-3/4
(mm) 72.5 368.3 598.4 147.9 180.3 73.2 120.8 200.0 95 95
GC300-V2 (in) 2.86 14.00 23.688 5.57 7.44 3.38 5.04 8.15 4-1/4 4-1/4
(mm) 72.5 355.6 601.5 141.5 189.0 85.7 127.9 207.1 108 108
GC400-V2 (in) 2.86 17.50 28.78 7.32 8.67 3.88 5.32 8.44 5 5
(mm) 72.5 444.5 731.0 186.0 220.2 98.4 135.1 214.3 127 127
GC600-V2 (in) 2.86 19.00 32.08 8.07 10.70 3.88 5.44 8.55 5-1/4 5-1/4
(mm) 72.5 482.6 814.8 205.0 271.8 98.4 138.0 217.2 133 133

Standard Bushings

 Load Cell  Bushing ADAPTS TO PIN f
(in) (mm)
GC012-V2 PC401 1 25
GC018-V2 PC118 1-1/4 32
GC035-V2 PC424 1-1/2 38
PC425 1-5/8 41
PC426 1-3/4 44
PC427 1-7/8 48
PC428 2 50
PC429* 1-1/4 32
GC060-V2 PC114 2-1/4 57
PC115 2 51
GC100-V2 PC416 2-1/2 64
PC419 2-3/4 70
PC431 2 51
GC170-V2 PC448 2-1/4 57
PC449 2-1/2 64
GC250-V2 PC443 2-1/4 57
PC444 2-3/4 70
PC445 3-1/4 83
GC300-V2 PC446 3-3/4 96
PC447 4-1/8 105
GC400-V2 PC453 4-1/8 105
PC454 4-1/4 108
PC455 4-3/4 121
GC600-V2 PC456 5 127

Standard included bushings are in bold and depends on adapter plate kit when load cell and adapter plate kit are ordered together.  Fits in the 1-5/8 hole, the other bushings for the GC035 fit in the 2-1/4 hole.

Adapter Plate Kits  (designed with a 5:1 safety factor)

Trimble-GS200A-Wireless-Load-Cell- (4)

Load Kit # Plate Pin Number Pin Nut Washer Nut Cotter Pin Washer Bushing* WLLb
Cell ITM 1 ITM 2 ITM 3 ITM 4 ITM 5 ITM 6 Qty ITM 7 (kg)
GC012-V2 LC612-01 PC612-01 1 PC501 QW912 QV930 QP003S QW901 6 PC401 12,000(5454)
2 PC502 QW912 QV930 QP003S QW902 6
GC018-V2 LC618-01 PC618-01 1 PC502 QW912 QV930 QP003S QW902 4 PC118 18,000(8181)
2 PC503 QW912 QV930 QP003S QW906 4
GC035-V2 LC635-01 PC635-01 1 PC502 QW912 QV930 QP003S QW902 2 PC429 35,000(15909)
2 PC502 QW912 QV930 QP003S QW902 2 PC423
LC635-02 PC635-02 1 PC506 QW902 QV950 QP003S QW903 6 35,000(15909)
2 PC504 QW907 QV951 QP004S QW904 6 PC428
LC635-03 PC635-03 1 PC506 QW902 QV950 QP003S QW903 6 35,000(15909)
2 PC505 QW902 QV950 QP003S QW903 6 PC424
LC635-04 PC635-04 1 PC506 QW902 QV950 QP003S QW903 6 PC424 35,000(15909)
2 PC505 QW902 QV950 QP003S QW903 6 PC424
LC635-06 PC635-02(w/ PC432) 1 PC524 QW902 QV951 QP003S QW908 6 PC427 35,000(15909)
2 PC506 QW903 QV950 QP003S QW903 6
LC635-07 PC635-02 (w/ PC417) 1 PC519 QW902 QV951 QP004S QW908 6 PC426 35,000(15909)
2 PC506 QW903 QV950 QP003S QW903 6
LC635-09 PC635-05 1 PC522 QW903 QV951 QP004S QW904B 4 35,000(15909)
2 PC506 QW903 QV950 QP003S QW903 4
GC060-V2 LC660-01 PC660-01 1 PC506 QW902 QV950 QP003S QW903 2 PC108 60,000(27272)
2 PC506 QW902 QV950 QP003S QW903 2 PC108
LC660-02 PC660-02 1 PC508 QW903 QV951 QP004S QW904B 4 PC114 60,000(27272)
2 PC507 QW903 QV951 QP004S QW904 4 PC115
LC660-03 PC660-03 1 PC508 QW903 QV951 QP004S QW904B 4 PC114 60,000(27272)
2 PC507 QW903 QV951 QP004S QW904 4 PC115
LC660-04 PC660-04 1 PC508 QW903 QV951 QP004S QW904B 4 PC114 60,000(27272)
2 PC507 QW903 QV951 QP004S QW904 4 PC115
LC660-05 PC660-05 1 PC509 QW904 QV952 QP004S QW904C 10 60,000(27272)
2 PC509 QW904 QV952 QP004S QW904C 10
LC660-06 PC660-06 1 PC509 QW904 QV952 QP004S QW904C 10 60,000(27272)
2 PC509 QW904 QV952 QP004S QW904C 10

Bushings not included. Required bushings included with load when load cell and adapter plate are ordered together.

Adapter Plate Geometry

    Load Cell     Kit #    Pin 1 Diameter    Pin 2 Diameter     C     D     L     X     Y     Z
GC012-V2 LC612-01 (in) 1.00 1.25 4.23 2.00 3.75 0.50 3.00 6.75
(mm) 25.4 31.8 107.4 50.8 95.3 12.7 76.2 171.5
GC018-V2 LC618-01 (in) 1.25 1.38 4.23 1.75 4.25 0.63 3.00 7.35
(mm) 31.8 34.9 107.4 44.5 108.0 15.9 76.2 186.7
GC035-V2 LC635-01 (in) 1.25 1.25 4.23 1.50 4.25 0.75 4.00 8.25
(mm) 31.8 31.8 107.4 38.1 108.0 19.1 101.6 209.6
LC635-02 (in) 1.63 2.00 5.84 2.50 7.25 0.75 4.00 11.50
(mm) 41.3 50.8 148.3 63.5 184.2 19.1 101.6 292.1
LC635-03 (in) 1.63 1.50 5.53 2.50 10.25 0.75 4.00 14.50
(mm) 41.3 38.1 140.5 63.5 260.4 19.1 101.6 368.3
LC635-04 (in) 1.63 1.50 5.53 2.50 36.00 0.75 4.00 40.25
(mm) 41.3 38.1 140.5 63.5 914.4 19.1 101.6 1022.4
LC635-06 (in) 1.88 1.63 5.84 2.50 7.25 0.75 4.00 8.25
(mm) 47.6 41.3 148.3 63.5 184.2 19.1 101.6 209.6
LC635-07 (in) 1.75 1.63 5.84 2.50 7.25 0.75 4.00 8.25
(mm) 44.5 41.3 148.3 63.5 184.2 19.1 101.6 209.6
LC635-09 (in) 2.25 1.63 5.84 2.50 6.00 0.75 4.00 10.10
(mm) 57.2 41.3 148.3 63.5 152.4 19.1 101.6 256.5
GC060-V2 LC660-01 (in) 1.63 1.63 5.53 2.00 5.25 1.00 5.00 10.25
(mm) 41.3 41.3 140.5 50.8 133.4 25.4 127.0 260.4
LC660-02 (in) 2.25 2.00 6.34 2.50 5.25 1.00 5.00 10.50
(mm) 57.2 50.8 161.0 63.5 133.4 25.4 127.0 266.7
LC660-03 (in) 2.25 2.00 6.34 2.50 11.25 1.00 5.00 16.50
(mm) 57.2 50.8 161.0 63.5 285.8 25.4 127.0 419.1
LC660-04 (in) 2.25 2.00 6.34 2.50 24.00 1.00 5.00 29.25
(mm) 57.2 50.8 161.0 63.5 609.6 25.4 127.0 743.0
LC660-05 (in) 2.50 2.50 8.09 3.00 7.25 1.00 5.00 12.50
(mm) 63.5 63.5 205.5 76.2 184.2 25.4 127.0 317.5
LC660-06 (in) 2.50 2.50 8.09 3.00 11.25 1.00 5.00 16.50
(mm) 63.5 63.5 205.5 76.2 285.8 25.4 127.0 419.1

Adapter Plate Kits

Trimble-GS200A-Wireless-Load-Cell- (5)

   Load Cell    Kit #   Adapter Bar   Pin Number    Pin   Nut Washer    Nut   Cotter Pin    Washer    Bushing   WLLlb
ITM 1 ITM 2 ITM 3 ITM 4 ITM 5 ITM 6 Qty ITM 7 (kg)
GC035-V2 LC635-51 PC635-51 1 PC531 — QV954 QP003 — — — 35,000(15909)
2 PC530 — QV954 QP003 — — PC405
GC060-V2 LC660-51 PC660-51 1 PC507 QW903 QV951 QP004S QW904 4 PC108 60,000(27272)
— — — — — — — —
   `    Kit #   Pin 1 Diameter   Pin 2 Diameter    C    D    L    X    Z
GC035-V2 LC635-51 (in) 1.63 1.50 3.93 1.50 24.00 0.75 28.00
(mm) 41.3 38.1 99.8 38.1 609.6 19.1 711.2
GC060-V2 LC660-51 (in) 2.00 3.00* 6.34 2.50 45.00 1.00 50.50
(mm) 50.8 76.2* 161.0 63.5 1143.0 25.4 1282.7

Pin not included with Adapter kit

  • PMN: GC018-V2, GC035-V2
  • HVIN: MB103-00-SD-A

FCC Compliance Statement (USA)

FCC ID: S9E-GS200A
Compliance Statements: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including, an interference that may cause undesired operation.

Caution Statements:

  • Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
  • This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

Industry Canada (IC) Compliance Statement

IC: 5817A-GS000A

Compliance Statements: This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.,
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

Caution Statements:

  • This equipment complies with radio frequency exposure limits set forth by Industry Cananda for an uncontrolled environment.
  • This equipment should be installed and operated with a minimum distance of 20 cm between the device and the user or bystanders.

Information to the User

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FAQ

Q: What battery types are recommended for the load cell?
A: Only use Tadiran TL-5930 3.6V or Saft LS33600 cell 3.6V as per the warning in the manual.

Documents / Resources

PDF thumbnailGS200A Wireless Load Cell
Owner's Manual · GS200A, S9E-GS200A, S9EGS200A, GS200A Wireless Load Cell, Wireless Load Cell, Load Cell

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.