iGAZE PLUS 915 Radio System For Sensitive Safety Edges
Product Information: iGAZE PLUS 915
Specifications:
- RADIO SYSTEM FOR SENSITIVE SAFETY EDGES
- Model: iGAZE PLUS 915
- Receiver Model: RCOO PLUS 915
- Transmitter Model: TCOO PLUS 915
- Rev: 0 – 25/10/2024
Product Description:
Intended Use:
The iGAZE PLUS 915 is designed as a radio system for sensitive
safety edges, providing advanced safety features for various
applications.
Technical Characteristics:
The product operates using the RCOO PLUS 915 receiver and TCOO
PLUS 915 transmitter, ensuring reliable communication between
devices.
Overall Dimensions:
The product dimensions are specified to ensure compatibility
with standard installation requirements.
Batteries:
The product may require batteries for operation. Refer to the
specific instructions for battery type and installation.
Product Usage Instructions:
Assembly and Installation:
Fixing the Devices and Installation Advice:
Follow the provided guidelines to securely fix the receiver and
transmitter in the designated locations.
Connect the Receiver to the Control Panel:
Establish the necessary connections between the receiver and the
control panel as instructed.
Connect the Sensitive Safety Edge to the
Transmitter: Ensure proper connection between the safety
edge and the transmitter for seamless operation.
Programming:
Association between TCOO and RCOO (Learning):
Learn how to associate the transmitter and receiver for effective
communication.
Total Deletion of Memory: Understand the
process of clearing the device memory for maintenance or
reprogramming purposes.
Maintenance:
Regular maintenance ensures optimal performance. Refer to the
maintenance section for guidelines on upkeep.
Product Disposal:
Follow recommended procedures for environmentally friendly
disposal of the product at the end of its lifecycle.
System Diagnostic:
Utilize the diagnostic features to troubleshoot any operational
issues and ensure system functionality.
FCC Compliance:
The product complies with FCC regulations for safe and legal
operation within specified parameters.
FAQ:
General Warnings for the Installer:
Danger – Batteries: Exercise caution when
handling batteries to prevent any potential hazards during
installation or replacement.
iGAZE PLUS 915
RADIO SYSTEM FOR SENSITIVE SAFETY EDGES
INSTALLATION AND USE MANUAL RCOO PLUS 915 – receiver TCOO PLUS 915 – transmitter
6-1620189M – rev. 0 – 25/10/2024 ENGLISH – Translated from the original language
INDEX
1. GENERAL WARNINGS FOR THE INSTALLER
3
1.1 – GUIDELINES ON ELECTRICAL CONNECTIONS
5
2. PRODUCT DESCRIPTION
6
2.1 – INTENDED USE
6
2.2 – TECHNICAL CHARACTERISTICS
6
2.3 – OVERALL DIMENSIONS
7
2.4 – BATTERIES *
7
3. RECEIVER “RCOO PLUS 915”
8
3.1 – DESCRIPTION OF THE RECEIVER
9
3.2 – ADVANCED RADIO CHECK FUNCTION
9
4. TRANSMITTER “TCOO PLUS 915”
10
4.1 – DESCRIPTION OF THE TRANSMITTER
10
5. ASSEMBLY AND INSTALLATION
11
5.1 – FIXING THE DEVICES AND INSTALLATION ADVICE
11
5.2 – CONNECT THE RECEIVER TO THE CONTROL PANEL
12
5.3 – CONNECT THE SENSITIVE SAFETY EDGE TO THE TRANSMITTER
13
6. PROGRAMMING
13
6.1 – ASSOCIATION BETWEEN TCOO AND RCOO (LEARNING)
13
6.2 – TOTAL DELETION OF MEMORY
14
7. MAINTENANCE
14
8. PRODUCT DISPOSAL
14
9. SYSTEM DIAGNOSTIC
15
10. FCC COMPLIANCE
15
2 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
1. GENERAL WARNINGS FOR THE INSTALLER
DANGER
RISK OF ELECTRIC SHOCK, EXPLOSION OR ELECTRIC ARC · Shut down all equipment, including connected devices, before removing any lid or door, or before installing/uninstalling accessories, hardware, cables or wires, except for the conditions specified in the user manual for this equipment. · To verify that the system is out of voltage, always use a correctly calibrated voltmeter at the rated value of the voltage. · Before returning the live unit, reassemble and secure all covers, hardware and cables. Make sure that the cable inlet is sealed to prevent insect entry and moisture formation. · Use this equipment and all products connected only to the specified voltage. · If there is a risk of damage to personnel and/or equipment, use the necessary safety interlocks. · Do not disassemble, repair or modify the equipment. · This product is not suitable for installation in applications where it may come into contact with explosive or flammable atmosphere. Failure to comply with these instructions will result in death or serious injury.
DANGER
RISK OF ELECTRIC SHOCK AND/OR FIRE · Do not expose the equipment to liquid substances. · Do not exceed the temperature and humidity ranges specified in the technical data and leave the slit area ventilated. · Only connect compatible accessories in the user manual. · Use only cables of appropriate cross-section as indicated in the section “GUIDELINES FOR ELECTRICAL CONNECTIONS”. Tighten the connections in accordance with the technical specifications for the tightening torques and verify the correct wiring. · Electrical cables must not come into contact with parts that can heat and parts of the automation in motion. Failure to comply with these instructions will result in death or serious injury.
DANGER – BATTERIES
RISK OF OVERHEATING, EXPLOSION, FIRE OR BURN · If the battery is intact, store and handle carefully, there is no danger (it is recommended to handle the batteries in a ventilated place, do not smoke, eat or drink during assembly). · Do not expose to temperatures above 100 ºC (temperature <85 ºC recommended). · Avoid short circuit, crushing and exposure to heat sources. · Do not disassemble, drill, heat or wet batteries or battery packs, do not throw batteries into the fire. · Substances to avoid: water, oxidizing agents, alkalis. · Keep new and used batteries out of the reach of children. · If the battery compartment does not close tightly, suspend the use of the product and keep it out of reach of children. · If you suspect that the batteries have been swallowed or inserted into other body orifices, seek medical attention immediately. · Only use batteries of the specified type. Risk of explosion if battery is replaced with wrong type. Failure to comply with these instructions will result in death or serious injury.
6-1620189M – rev. 0 – 25/10/2024
Translated from the original language – English – 3
WARNING
RISK OF OVERHEATING AND/OR FIRE · Do not use with loads other than those indicated in the technical data. · Power lines and output connections must be properly wired and protected by fuses when required by national and local regulatory requirements. Failure to comply with these instructions may result in death, serious injury or damage to equipment.
WARNING
GENERAL ASPECTS OF SAFETY AND REGULATORY INCOMPATIBILITY · Any use of this product other than the permitted use /intended use is prohibited. · The manufacturer cannot be held liable for damage that occurs as a result of improper use or as a result of an installation that does not comply with the requirements of this manual. · The liability of the manufacturer for damages resulting from accidents of any nature caused by defective products, are only those provided for by legal obligations. · All operations indicated in this manual must be carried out exclusively by experienced, qualified and trained personnel. · The preparation of the cables, the laying, the connection and the testing must be carried out observing the rule of art, in compliance with the rules, regulations and laws in force. · During installation, testing and maintenance, properly delimit the entire site to avoid access by unauthorized persons, in particular minors and children. · Before proceeding with the installation, check the mechanical goodness of the movable door and the support and guide structure. · Keep this manual in the technical file together with the manuals of the other devices used for the realization of the automation system. · Ensure that all equipment used and systems designed comply with all applicable local, regional and national regulations and regulations. Failure to comply with these instructions may result in death, serious injury or damage to equipment. · The data included in this manual have been compiled and verified with the utmost care, however the manufacturer cannot accept any responsibility for any errors, omissions or approximations due to technical or graphic requirements. · The manufacturer reserves the right to change the specifications of the appliance without prior notice. · The manufacturer recalls that this manual does not replace the provisions of the rules that the manufacturer of the motorized door/gate is required to comply with. The manufacturer assumes no liability for any consequences arising from the misuse of this material.
WARRANTY – The manufacturer’s warranty is valid by law from the date printed on the product and is limited to the free repair or replacement of parts recognized by the manufacturer as defective due to lack of essential qualities in the materials or for errors in the production process. The warranty does not cover damage or defects due to external agents, lack of maintenance, overload, normal wear, installation error, or other causes not attributable to the manufacturer. Tampered products will not be covered by warranty. The manufacturer is not responsible for malfunctions or degradation of performance due to environmental interference, such as electromagnetic disturbances; therefore, the warranty expires in these situations.
4 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
1.1 – GUIDELINES ON ELECTRICAL CONNECTIONS
Prepare cable ducts on the installation site. The cables for the connection of the various devices in a typical plant are listed in the table below and must be suitable for the type of installation. To connect the RCOO to the gate operator, use wiring type CL2, CL2P, CL2R, CL2x complying with UL13 or other cables with equivalent or better electrical, mechanical and flammability ratings shall be used.
CONNECTION Power supply voltage – receiver Connection to the control panel
CABLE 2 x 1,5 mm² 2 x 0,5 mm²
LENGTH < 20 m < 20 m
The following table shows the type and size of the allowable cables for the screw terminals of the above type and the tightening torques:
mm 6.5 in. 0.26
mm2
0.2 … 2.5
0.2 … 2.5
0.25 … 2.5
2 x 0.2 … 0.75
2 x 0.2 … 0.75
2 x 0.25 … 0.75 2 x 0.25 … 0.75 2 x 0.5 … 1.5
AWG
24 … 14
24 … 14
24 … 14
24 … 14
2 x 24 … 18
2 x 24 … 18
2 x 24 … 18
2 x 20 … 16
Ø 3.5 mm (0.14 in.)
Use copper conductors (mandatory). Avoid the presence of wires of exposed branches or coming out of the clamp.
N · m 0.5 Ib-in 4.5
6-1620189M – rev. 0 – 25/10/2024
Translated from the original language – English – 5
2. PRODUCT DESCRIPTION
The iGAZE PLUS 915 system allows radio (wireless) operation to transmit the signal of a sensitive safety edge to the control unit (CU). The receiver (RCOO) constantly checks the status of the transmitters connected to it (TCOO) and automatically selects the transmission frequency that guarantees the best communication quality among those available. The receiver sets its output to alarm state when an obstacle is detected from the sensitive safety edge connected to the transmitter. Up to two TCOO can be connected to an RCOO. Each RCOO has two outputs that can be connected to the control unit.
RCOO
TCOO 1
EDGE A EDGE B
CU 2.1 – INTENDED USE
TCOO 2
EDGE C EDGE D
Radio system for connecting sensitive safety edges to control panels for the automation of residential, commercial and industrial doors and gates. Any installation and use different from what is indicated in the following manual are prohibited.
2.2 – TECHNICAL CHARACTERISTICS
Commercial name Construction of the device Width of the communication channel Working frequency (automatically selected)
Supply voltage
Current consumption RCOO Battery life (TCOO) * Radiated power RCOO radio memory RCOO relay output (OUT1 / OUT2)
Usable sensitive edge types (EDGE1 / EDGE2)
Maximum reaction time for safety edge intervention Radio communication diagnostic range Minimum distance between devices Maximum distance between devices (in open field) Environmental operating conditions Conditions of transport and storage Degree of environmental protection
TCOO PLUS 915
RCOO PLUS 915
Electronic device with independent installation
260 KHz
902,0 ÷ 928,0 MHz
2 x 1,5V (alkaline LR6/AA batteries)
12-24 Vac/dc
< 70 mA @ 12Vdc
12 ÷ 24 months
< 25 mW
MAX 2 TCOO
Dry contact (MAX 24 Vac/dc 0.1 A)
Resistive edges (10K – 8,2K Ohm) Mechanical edges (normally closed contact)
40 ms
1 s
0,5 m
50 m
TA: -20…+55 °C RH max 90% non-condensing
TA: -40…+70 °C RH max 90% non-condensing
IP65
6 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
2.3 – OVERALL DIMENSIONS
31
120
90
157
IP65
54 25
2.4 – BATTERIES *
WARNING
BATTERY LIFE AND USE · Battery life depends on the quality of radio communication between devices. The quality of the radio communication can decrease in the presence of shielding or reflection phenomena that can occur during the movement of the automation. For this reason, the number of manoeuvres per day can also affect the total battery life. Check the signal quality with the advanced RADIO CHECK function. · Do not mix new and discharged batteries. · Before disposing of the equipment, remove the batteries and place them in an appropriate waste disposal place. Check the provisions of your municipality of residence.
WARNING
STORAGE OF BATTERIES · Store batteries in a cool, dry place away from heat or flames. · The recommended maximum storage temperature is 30 ºC. If higher temperatures are reached, batteries may become damaged and/or discharge prematurely. In any case, do not exceed 100 ºC, as the batteries can be damaged causing a leak of harmful substances. · Do not subject batteries to mechanical shock or stress. · Keep batteries in their original packaging until they are used. · Do not expose batteries to direct sunlight.
6-1620189M – rev. 0 – 25/10/2024
1,5V type AA
1,5V type AA
Translated from the original language – English – 7
3. RECEIVER “RCOO PLUS 915”
9 1
8 2
7
3
4
5
6
1. LED POWER ON 2. DIP-SWITCH selector for configuration (TAB.1) 3. Terminal block for connection of the supply voltage
(Valim) 4. Terminal block for connection of the OUT1 output 5. Terminal block for connection of the OUT2 output 6. Terminal block for connection of the TEST control (Vtest) 7. PROG/RESET button 8. Buzzer for acoustic signals 9. Antenna
LED
OFF
POWER ON RCOO not powered
RADIO CHECK
L1
L2
PROG/RESET
No communication from an associated TCOO
OUT1 output in consensus
OUT2 output in consensus
RCOO in normal operation mode
ON RCOO properly powered
No associated TCOO
OUT1 output in alarm OUT2 output in alarm RCOO in programming mode
TAB.1 DIP SWITCH SELECTOR
1 – TEST POLARITY
2 – RADIO CHECK 3 – BUZZER OFF 4 – OUT1 10k * 5 – OUT2 10k *
OFF
ON
Test control with positive polarization: TEST not active = OV TEST active = 12/24vdc
Test command with negative polarization: TEST not active = 12/24vdc TEST active = 0V
Verification of the presence of associated TCOO Verification of the quality of radio communication
(Normal functionality)
between RCOO and TCOO (Advanced functionality)
Enable the acoustic signals
Disable the acoustic signals
Output C1-NO1: Contact Normally Open
Output C1-NO1: Contact 10K OHM
Output C2-NO2: Contact Normally Open
Output C2-NO2: Contact 10K OHM
*: Selectors 4 and 5 do not change the functionality of the outputs C1-NC1 and C2-NC2 (Contact Normally Closed). In the table below you can see, for each configuration, the status of the outputs depending on whether they are in consent or alarm.
TAB.2 DIP-SWITCH 4 – OUT1 10k * 5 – OUT2 10k *
C1-NC1 C1-NO1 C2-NC2 C2-NO2
CONSENT closed circuit open circuit closed circuit open circuit
OFF ALARM open circuit closed circuit open circuit closed circuit
CONSENT closed circuit 10K ohm closed circuit 10K ohm
ON ALARM open circuit closed circuit open circuit closed circuit
8 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
3.1 – DESCRIPTION OF THE RECEIVER
The receiver, once powered, before having associated a TCOO, looks like this: · POWER LED on (properly powered device); · The LED RADIO CHECK turned on fixed (no TCOO learned); · Both L1 and L2 LEDs on (outputs in alarm state).
Once you have learned a TCOO, the RADIO CHECK LED, in its normal functionality, gives immediate feedback of the radio packets received by its associated transmitters by flashing a short.
The buzzer on the board allows you to have immediate acoustic information on the diagnostics of the associated transmitters, depending on the number of acoustic signals emitted.
ACOUSTIC SIGNALS
DESCRIPTION
ASSOCIATED OUTPUT
1 –
Press the TEST button of an associated TCOO.
Consent
2 –
Input of a TCOO associated in alarm.
Alarm
4 –
Notice of battery replacement of an associated TCOO.
Consent
6 –
Failure to communicate with an associated TCOO.
Alarm
When the batteries on the transmitter are almost empty and reach the voltage of 2.1V, the receiver warns the user of the imminent need to replace the batteries by performing 4 beeps every minute. During these reports the system is still working, but it is advisable to consider whether to proceed to the replacement of the batteries before the automation stop occurs. In case of no communication with an associated TCOO, the receiver will perform 6 beeps every minute and will bring all its outputs in alarm state.
3.2 – ADVANCED RADIO CHECK FUNCTION
WARNING
· Low signal coverage results in increased battery consumption.
The RADIO CHECK function allows to know the quality of the radio communication between a TCOO and an RCOO. This characteristic may depend on the presence of devices that generate radio noise, or phenomena of shielding and reflection due to metal bodies present in the installation itself. In this mode the RADIO CHECK LED performs a number of flashes every second proportional to the quality of the radio coverage at that time. It is therefore advisable to perform some complete movements of the automation so that you can evaluate the overall quality of radio communication between the devices in your installation.
· To activate the RADIO CHECK mode, move the DIP-SWITCH on the RCOO to the ON position. · Press a safety edge to start displaying the status of the radio transmission between the TCOO to which that safety edge is connected and the associated receiver.
LED RADIO CHECK
DESCRIPTION
1 –
Low radio coverage.
2 –
Medium radio coverage.
3 –
Good radio coverage.
· Once all the checks are completed, you can return the DIP-SWITCH switch of the RCOO to the OFF position to exit the RADIO CHECK function.
6-1620189M – rev. 0 – 25/10/2024
Translated from the original language – English – 9
4. TRANSMITTER “TCOO PLUS 915”
1,5V type AA 1,5V type AA
1
8
2
6
1. Housing for the batteries 2. Connector for connecting the batteries 3. LED TEST1 and TEST2 4. TEST1 and TEST2 buttons 5. DIP-SWITCH selector for configuration (TAB.3) 6. Terminal block for connecting the safety sensitive board
(EDGE1) 7. Terminal block for connecting the safety sensitive board
(EDGE2) 8. Antenna
LED TEST1 TEST2
OFF –
ON
Pressing the TEST1 button
Pressing the TEST2 button
3
7
4
5
TAB.3 DIP SWITCH SELECTOR 1 – EDGE 1 RESIST
2 – EDGE 2 RESIST 3 – P. MODE
OFF
Safety sensitive edge, mechanical type (Normally Closed contact) connected to the EDGE1 input
Safety sensitive edge, mechanical type (Normally Closed contact) connected to the EDGE2 input
Not used
ON Safety sensitive edge, resistive type (8K2 ÷ 10K OHM) connected to EDGE1 input
Safety sensitive edge, resistive type (8K2 ÷ 10K OHM) connected to EDGE2 input
4.1 – DESCRIPTION OF THE TRANSMITTER
WARNING
· Do not transport or store the TCOO with batteries connected to the board.
Once it is associated with an RCOO, the transmitter sends the information to the receiver once every second and every time the sensitive safety edge connected to its terminals detects an impact or is disconnected.
10 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
5. ASSEMBLY AND INSTALLATION
5.1 – FIXING THE DEVICES AND INSTALLATION ADVICE
WARNING
· Grommets and gaskets must be installed to ensure IP65 protection. · Replace the grommets with caps on the holes that are not used. · Install the devices so that the output of the cables is facing down. · Always maintain a minimum distance of at least 20 cm between the transmitter and the receiver. · Do not place metal surfaces between transmitter and receiver. · To maximize the range of action, both devices must be installed with the same orientation (horizontally or vertically) and at the same height. · Do not place the equipment at ground level. Failure to comply with these instructions can cause a significant drop in system performance, resulting in possible automation stop.
20
IP65
73
1,5V type AA 1,5V type AA
Ø3.6
133,8
103
30
6-1620189M – rev. 0 – 25/10/2024
Translated from the original language – English – 11
5.2 – CONNECT THE RECEIVER TO THE CONTROL PANEL
OUT1 OUT2 Valim
· Connect the supply voltage (Valim) to the RCOO board. · Connect the desired output (OUT 1 and/or OUT 2) to the control unit. You can connect this output to an 10K safety edge input or directly into a safety input with normally closed contact (such as a photocell input or a STOP input). · Depending on the input type used in the control unit, select the corresponding type with the use of the DIP-SWITCH 4 and 5 selectors. · Set the DIP-SWITCH 1 to select the polarity of the test command.
TEST POLARITY ON
OFF
NEGATIVE POLARIZATION: The test control is a fixed 12 or 24V signal, which the control unit brings to 0 to carry out the system verification.
POSITIVE POLARIZATION: The test control shall be voltage-free. The control unit shall carry this control at 12 or 24V to verify the system.
WARNING
· If the control unit is working without a test control, the TEST POLARITY selector must be set to POSITIVE POLARITY (OFF position).
CONNECTION OF THE TEST CONTROL
Use the TEST1 input for the test run on the OUT1 output. Use the TEST2 input for the test run on the OUT2 output.
12/24Vdc
Vtest (-) Vtest-OUT2 (+) Vtest-OUT1(+)
12 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
5.3 – CONNECT THE SENSITIVE SAFETY EDGE TO THE TRANSMITTER
· Connect the safety sensitive edge to the desired input (EDGE1 or EDGE2). · Depending on the type of edge used, select the corresponding type in the DIPSWITCH selector.
Configuration example for EDGE1 input:
EDGE1 RESIST
RESISTIVE EDGE
ON
RESIST
MECHANICAL EDGE OFF
· Insert the battery into the dedicated housing and connect the connector to the board.
6. PROGRAMMING
6.1 – ASSOCIATION BETWEEN TCOO AND RCOO (LEARNING)
WARNING
· The learning procedure is automatically abandoned for TIME OUT after 30 seconds from the last key pressed on the RCOO. · During the learning procedure both outputs remain alert. · You can map the association between TCOO input and RCOO outputs again by repeating the learning procedure and setting the desired configuration.
· Make sure the devices are turned on properly. · Press and hold the PROG/RESET button for at least 3 seconds, when the PROG/RESET LED lights up fixed release the button. · At this stage you can select in which output (OUT1 and/or OUT2) you want to learn an input of a TCOO. Use the PROG/RESET button to select the desired option.
LED L1 FLASHING
OFF FLASHING
LED L2 OFF
FLASHING FLASHING
DESCRIPTION The input will be learned on the OUT1 output. The input will be learned on the OUT2 output. The input will be learned on the OUT1 and OUT2 outputs.
· Press the TCOO button you want to associate (TEST1 or TEST2). · In the RCOO the L1 and L2 LEDs both light up and the buzzer makes two beeps to confirm the programming. · After the procedure the LED PROG/RESET turns off.
6-1620189M – rev. 0 – 25/10/2024
Translated from the original language – English – 13
6.2 – TOTAL DELETION OF MEMORY
WARNING
· This procedure involves the cancellation of all TCOO learned in the receiver. · The cancellation procedure is automatically abandoned for TIME OUT after 10 seconds, or if the PROG/ RESET key is pressed for a time not long enough. · In case of replacement of a TCOO it is necessary to perform the total erasure of the memory and then re-program all the TCOO used.
· Press and hold the PROG/RESET button for at least 7 seconds, when the PROG/RESET, L1 and L2 LEDs flash quickly release the button. · Within 10 seconds, press and hold the PROG/RESET button for at least 3 seconds to perform total memory erase. · When the L1 and L2 LEDs blink slowly release the PROG/RESET button. · The buzzer performs three audible signals to indicate correct cancellation and the PROG/RESET LED turns off. · Below the L1, L2 and CHECK LEDs light fixed.
7. MAINTENANCE
Before carrying out any cleaning, maintenance or replacement of parts, remove power to the automation. Every 12 months of operation, the following maintenance measures are mandatory: · Check and clean any dirt, insects and dust residues that have been placed inside. · Check the integrity of the cables and their connections, including clamping contact, and make the necessary replacements. · Verify the integrity of the protective shells and sensitive safety edges connected to the TCOO, and perform the necessary replacements. · Perform a general and complete check of the screws and bolts. · Perform a functional product check by checking the correct operation of the switchboard in the event of an RCOO output alarm. · Check battery status and replace if necessary.
8. PRODUCT DISPOSAL
As for installation operations, the disassembly of this product must be carried out by qualified personnel. The symbol on the side indicates that the product should not be disposed of as unsorted waste, but should be sent to separate collection facilities for recovery and recycling. For disposal check the recycling or disposal systems provided by the territorial regulations in force for this category of product, or return the product to the seller. WARNING – · This product consists of various types of materials: some parts of the product may contain pollutants or dangerous substances that, if dispersed, could cause harmful effects to the environment and health. · Local regulations may provide for heavy penalties in the event of incorrect disposal of this product
14 – English – Translated from the original language
6-1620189M – rev. 0 – 25/10/2024
9. SYSTEM DIAGNOSTIC
PROBLEM
POSSIBLE CAUSE
The receiver emits 2 acoustic signals every 5 seconds.
The receiver emits 4 acoustic signals every minute.
The receiver emits 6 acoustic signals every minute.
Input of the TCOO in alarm.
Incorrect setting of TCOO input. Battery level of an associated TCOO is low. Drained battery of an associated TCOO.
Low radio coverage or presence of strong radio noise.
Batteries in a TCOO drain quickly.
Low radio coverage or presence of strong radio noise.
I can’t do the learning.
Full radio memory.
SOLUTION
Verify that the sensitive edge is properly connected and working.
Check the TCOO DIP-SWITCH selector setting.
Check the batteries of the TCOO and perform the necessary replacements.
Check the batteries of the TCOO and perform the necessary replacements
Perform the RADIO CHECK procedure to improve the installation position of the TCOO and RCOO (see chapter INSTALLATION TIPS).
Perform the RADIO CHECK procedure to improve the installation position of the TCOO and RCOO (see chapter INSTALLATION TIPS).
The RCOO can learn a maximum of 2 TCOO. If necessary, erase the memory and learn the TCOO again.
10. FCC COMPLIANCE
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
NOTE: this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/ tv technician for help.
FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
6-1620189M – rev. 0 – 25/10/2024
Translated from the original language – English – 15
2480 South 3850 West, Suite Salt Lake City, UT 84120 866-975-0101 · 866-975-0404 fa www.transmittersolutions.com
Documents / Resources
![]() | TRANSMITTER SOLUTIONS iGAZE PLUS 915 Radio System For Sensitive Safety Edges [pdf] Installation Guide iGAZE PLUS 915, iGAZE PLUS 915 Radio System For Sensitive Safety Edges, Radio System For Sensitive Safety Edges, Sensitive Safety Edges |