TRANE logoSubmittal
5.0 Ton
Convertible Air Handler
A4AH4E60B1C30A
TRANE A4AH4E60B1C30A RunTru Central Air Conditioner Split SystemSeptember 2022
AA44AAHH44EE6600BB11CC-
-SSUUBB–11AA–EENN

Outline Drawing

TRANE A4AH4E60B1C30A RunTru Central Air Conditioner Split System - Drawing

PRODUCT DIMENSIONS
Air Handler ModelABCDEFHFlow ControlGas Line Braze
A4AH4E60B1C30A57.4023.5021.5021.754.689.6627.19TXV7/8
All dimensions are in inches

Product Specifications

MODELA4AH4E60B1C30A
RATED VOLTS/PH/HZ208-230/1/60
RATINGS(a)See O.D. Specifications
INDOOR COIL — TypePlate Fin
Rows — F.P.I.3 – 16
Face Area (sq. ft.)7.9
Tube Size (in.)3/8
Refrigerant ControlTXV
Drain Conn. Size (in.)(b)3/4 NPT
DUCT CONNECTIONSSee Outline Drawing
INDOOR FAN — TypeCentrifugal
Diameter-Width (In.)11 X 11
No. Used1
Drive – No. SpeedsDirect – 5 (c)
CFM vs. in. w.g.See Fan Performance Table
No. Motors — H.P.1 – 3/4
Motor Speed R.P.M.1050
Volts/Ph/Hz208-230/1/60
F.L. Amps6.0
FILTER
Filter Furnished? (d)No
REFRIGERANTR-410A
Ref. Line ConnectionsBrazed
Coupling or Conn. Size — in. Gas7/8
Coupling or Conn. Size — in. Liq. 

3/8

DIMENSIONSH x W x D
Crated (In.)57–1/8 x 27–1/2 x 25–1/2
Uncrated55-3/4 x 23-1/2 x 21-1/8
WEIGHT
Shipping (Lbs.) / Net (Lbs.)185/174

(a) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240). Refer to the Split System Outdoor Unit Product Data Guides for performance data.
(b) 3/4” Male Plastic Pipe (Ref: ASTM 1785–76)
(c) ECM Motor
(d) Remote filter required.

Minimum Airflow CFM

A4AH4E60B1C30A
HeaterMinimum Heat Speed Tap
With Heat PumpWithout Heat Pump
BAYHTR1504BRK, BAYHTR1504LUG, BAYHTR1505BRK, BAYHTR1505LUG, BAYHTR1508BRK, BAYHTR1508LUG, BAYHTR1510BRK, BAYHTR1510LUG, BAYHTR3510LUGMed-LowMed-Low
BAYHTR1517BRK, BAYHTR3517LUGMedMed
BAYHTR1523BRK, BAYHTR1525BRKMed-HighMed

Heater Pressure Drop Table

 

Airflow CFM

Number of RacksHeater Racks
1234Heater ModelNo. of Racks
Air Pressure Drop — Inches W.G.BAYHTR15041
18000.020.040.060.14BAYHTR15051
17000.020.040.060.14BAYHTR15082
16000.020.040.060.13BAYHTR15102
15000.020.040.060.12BAYHTR15173
14000.020.040.060.12BAYHTR35103
13000.020.040.050.11BAYHTR35173
12000.010.040.050.10BAYHTR35153
11000.010.030.050.09BAYHTR15234
10000.010.030.040.09BAYHTR15254
9000.010.030.040.08
8000.010.03
7000.010.02
6000.010.02

Performance and Electrical Data

  1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters.
  2. Heater model numbers may have additional suffix digits.

Table 1. Air Flow Performance

A4AH4E60B1C30A
EXTERNAL STATIC

(in w.g)

AIRFLOW
Speed Taps: 208 – 230 VOLTS
HighMed-HighMed †Med-LowLow
0.120401874165815121373
0.220081846162214761333
0.319751816158514381289
0.419421785154613951240
0.519091751150613491187
0.618751716146313001129
0.718411678141812461067
1.      Values are with wet coil, no filter, and no heaters
2.      CFM Correction for dry coil = Add 3%
3.      † = Factory Setting
4.      In downflow applications, airflow must not exceed 1800 cfm due to condensate blowoff.
5.      Low = Tap 1, Med-Low = Tap 2, Med = Tap 3, Med-High= Tap 4, High = Tap 5

Table 2. Electrical Data

A4AH4E60B1C30A
  Heater Model No.  No. of Circuits/ Phases240 Volt208 Volt
Capacity Heater Amps per Circuit Minimum Circuit Ampacity Maximum Overload Protec- tionCapacity 

Heater Amps per Circuit

Mini- mum Circuit Ampaci- ty 

Maximum Overload Protection

 

kW

 

BTUH

 

kW

 

BTUH

No Heater6.0 *8156.0 *815
BAYHTR1504BRK BAYHTR1504LUG1/13.81310016.028302.9980013.82525
BAYHTR1505BRK BAYHTR1505LUG1/14.81640020.033353.61230017.32930
BAYHTR1508BRK BAYHTR1508LUG1/17.72620032.048505.81970027.74245
BAYHTR1510BRK BAYHTR1510LUG1/19.63280040.058607.22460034.65160
BAYHTR1517BRK-
Circuit 1 (a)
 

 

2/1

9.63280040.058607.22460034.65160
BAYHTR1517BRK-
Circuit 2
4.81640020.025253.61230017.32225
BAYHTR1523BRK-
Circuit 1
 

 

2/1

9.63280040.058607.22460034.65160
BAYHTR1523BRK-
Circuit 2
9.63280040.050507.22460034.64345
A4AH4E60B1C30A
BAYHTR1525BRK-

Circuit 1

 

 

 

 

4/1

6.02050025.039404.51540021.63535
BAYHTR1525BRK-

Circuit 2

6.02050025.031354.51540021.62730
BAYHTR1525BRK-

Circuit 3

6.02050025.031354.51540021.62730
BAYHTR1525BRK-

Circuit 4

6.02050025.031354.51540021.62730
BAYHTR3510LUG1/39.63280023.136407.22460020.03235
BAYHTR3517LUG1/314.44910034.6505010.83690030.04445
BAYHTR1517BRK

with single circuit power source kit BAYSPEKT201A

1/114.44910060.0839010.83690051.97380
BAYHTR1523BRK

with single circuit power source kit BAYSPEKT201A

1/119.26550080.010811014.44910069.294100
* = Motor Amps

(a)  MCA and MOP for circuit 1 contains the motor amps.

Features and Benefits

  • Galvanized metal cabinet with captured foil face insulation
  • 2% or less air leakage
  • R-4.2 Insulating Value
  • Multi-Position UP/Down Flow, Horizontal Left /Right
  • ALL Aluminum Coil
  • Electric Heaters with polarized plug connections (sold as accessory)
  • R-410A Thermal Expansion Valve
  • ECM Motor (( 33..00 –– 55 TToonn MMooddeellss ))
  • Low Voltage Pigtail Connections
  • Draw Through Design
  • Horizontal Drain pan
  • Single Color
  • Fused 24V Power
  • 5year warranty
  • Optional extended warranty available

Important:Condensate management kit is required for all 5 ton air handler models installed in downflow applications.

About Trane and American Standard Heating and Air Conditioning
Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com.

TRANE A4AH4E60B1C30A RunTru Central Air Conditioner Split System - icon

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

A4AH4E60B1C-SUB-1A-EN 06 Sep 2022
Supersedes (New)

Documents / Resources

TRANE A4AH4E60B1C30A RunTru Central Air Conditioner Split System [pdf] Owner's Manual
A4AH4E60B1C30A RunTru Central Air Conditioner Split System, A4AH4E60B1C30A, RunTru Central Air Conditioner Split System, Air Conditioner Split System, Conditioner Split System

References

Leave a comment