TMT-AUTOMATION-LOGO

TMT AUTOMATION CB19 Control Box For Hermit

TMT-AUTOMATION-CB19-Control-Box-For-Hermit-PRODUCT

Control Box Installation

  1. Decide the installation position of the control box first, it is suggested to be installed near the gate and should be protected from possible damage. Be aware of the motor cable length before deciding the installation position.
  2. Remove the cover by unscrewing the four screws on the cover. See Figure A.
  3. Use a screwdriver to puncture the holes beneath the bottom of the control box. See Figure B.
  4. Secure it on the wall Figure C.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (1)

Wiring Connection

TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (2)

Motor Connection

  • a. Motor OnlyTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (3)
  • b. Motor With Limit Switch + LED indicatorTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (4)
  • c. Motor With Hall SensorTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (5)

Wifi Device

  • Functions of Buttons and TerminalsTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (6)
  • LED Description:
    • Blue: LED will be flashing during WIFI pairing, and be ON when completed.
    • Green: LED will be flashing if WB-001 receives a signal from the APP. If your home WIFI disconnects, the green light will continuously flash, and it will be off until WIFI is connected again.
    • Red: System failure or wrong PIN.

Back-up Batteries

Battery Power:

  • The battery white connector must be fitted the correct way round (positive red to +positive) or you will short circuit the control board. There are 2 x 12v batteries fitted under the control board.
  • They are connected in series to make 24vDC via a black cable with a yellow fuse with the positive of one battery to the negative of the second battery.
  • The remaining positive and negative terminals go to the control board as per the photo above.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (7)

Accessories

  • a. Photocells
    • The safety photocells are security devices for controlling automatic gates. Consists of one transmitter and one receiver based on waterproof covers; it is triggered while breaking the path of the beams.

Specification

Specification:
Detection MethodThrough Beam
Sensing RangeMAX~15m
Input VoltageAC/DC 12~24V
Contact CurrentTX: 30mA Max , RX: 25 mA Max
Response Time<100mS
Emitting ElementInfrared LED/ Wave Length: 940nm
Operation IndicatorRX: Red LED On (beam broken) / Off (beam aligned)

TX: Red LED On

Dimensions63*63*30 mm
Output MethodRelay Output
Current ConsumptionBeam aligned: RX<25ma\TX<30ma

Beam broken: RX <10ma\TX <30ma

Connection MethodTerminal Block
Housing MaterialABS / PC
Water ProofIP44
Safety StandardCE

TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (8) TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (9)

INSTALLATION

  1. Open the cover and connect the wires.
  2. Mounted the receiver and transmitter in the proper position.
  3. Ensure there are no obstacles between the receiver and the transmitter.
  4. For optimal efficiency, the receiver and transmitter should be properly aligned.
  5. Power up the photocells and make sure the LED light on the receiver and transmitter are ON.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (10)

Get Started

Note:

  • A. Transmitter memorizing must be done first before system learning.
  • B. CHECKING THE Gate MOVEMENTS
    • Release the gearmotor with the release key and move the gate to the middle so that it is free to move in both opening and closing directions; then lock the Gearmotor.
    • Perform the gate opening and closing several times and make sure the gates touch the limit switch at least 2~3 cm before the mechanical stop.
  1. Step 1: Remote Memorizing
    • a. Memorizing
      1. Press the button RF-Learn on the control board (Figure 1) as many times as the number corresponding to the desired command, according to the following table, Within 10s, press the desired button on the remote that you want it to be memorized (Figure 1)TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (11)
        Times for pressing RF-LearnCommandMessage code
        1 timeOpen-Stop-Close circleOLED display “OSC”
        2 timesPedestrian modeOLED display “PED”
      2. Make sure that the LED display shows the “OSC” or “PED” three times quickly. The code is corresponding to the selected command. (Figure 2)TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (12)
      3. Repeat steps 1 & 2 within 10, if there are other remotes to be memorized for the same type of command. If no action is within 10s, the memorization stage will terminate automatically.
    • b. Remote learning without a Control board
      1. Press the button on the NEW radio transmitter and hold it down for at least 5s, then release it.
      2. Press the button on the OLD radio transmitter 3 times. (Tip: Don’t press too fast; make sure you see the blue flash when pressing the button each time.)
      3. Press the button on the NEW radio transmitter once.
      4. Done, at this point, the NEW radio transmitter will copy the same command as the OLD one.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (13)
    • c. Deleting memory of a single command
      • A single deletion stage is needed for each memorized button.
        1. Press and hold down the RF-LEARN button (Figure 3) on the control board for 5 seconds.
        2. Wait until the LED display shows “DKY”, then, within three seconds:
        3. Press the button on the remote to be deleted. If the remote has been deleted, the LED display will flash quickly five times.
        4. Repeat the above steps if more buttons to be deleted.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (14)
    • d. Deleting all memory of all remotes
      • With this operation, all the memorized transmitters will be deleted.
        1. Press and hold down RF-LEARN button (Figure 4) on the control board for 10 seconds.
        2. Wait until the LED display shows “DAL”. (When you see DKY, keep pressing the RF-Learn till it shows DAL). All memory is deleted.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (15)
  2. Step 2: System Learning
    • Step1: Press and Hold the Press SET button for 3s, When the LED shows “LEA” then release SET, then the motor runs the system learning procedure automatically, once learning completed shows “D-G” or “S-G” (No remote required)
      1. Note: Please check the parameter setting of “FI”(Dual/Single) before going into system learning.
    • Restore the system default setting
      • Press and Hold the UP + SET + DOWN button for 5s and the panel restores to default setting
      • Note:
        1. LED Shows “D-G” tells the system learning has been completed for Dual Gate installation
        2. LED Shows “S-G” tells the system learning has been completed for Single Gate installationTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (16)
    • A. Dual Gate:
      • (1) Slave Gate Close » (2) Master Gate Close » (3) Master Gate Open
      • (4) Slave Gate Open » (5) Slave Gate Close » (6) Master Gate CloseTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (17)
    • B. Single Mode:
      1. Master Gate Close » (2) Master Gate Open » (3) Master Gate CloseTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (18)
        • For Single Gate installation, please make sure the motor cable connects to M1+/M1-, and the parameter to set function Fl-0 to the single gate, and also set FB-0 pedestrian mode to be function off, and once the system learning is completed, the LED will show S-G

Gate Operation Logic

  • A. In the gateopening phase: The gates stop if the transmitter/push button/key selector is activated, and close when the transmitter/push button/key selector is reactivated.
  • B. In the gateclosing phase: The gates stop if the transmitter/push button/key selector is activated, and open when the transmitter/push button/key selector is reactivated.

Safety For Gate Operation

  • In the gate-opening phase: For safety purposes, the gates stop if encountering obstacles.
  • In the gate-closing phase: For safety purposes, the gates reverse for 2 sec if encountering obstacles.

LED Indication

  1. LED Lighting
    • Blue LED System Learning: The Blue LED in the receiver board blinks two times when learning is completed.
    • LED2 RF: The key selector or the push button is activated, and LED2 will be on.
    • LED4 Ph1: LED4 will be on when Ph1 is triggered.
    • LED3 Ph2: LED3 will be on when Ph2 is triggered.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (19)
  2. The function of the LED displayTMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (20) TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (21)

Parameter Modification

Parameter Learning

  1. Press “UP+SET” for 3 seconds to get into the program setting display from F1.
  2. Press “UP” or “DOWN” to change setting item from F1 to FJ.
  3. Press “SET” button again to get into the sub-settings.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (22)
  4. Press “UP” or “DOWN” to change Push from F1-0 to F1-2.
  5. Press “SET” button again to confirm.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (23)

Parameter

SettingDefinitionParametersTableDescription
F1Motor TypeF1-0 F1-1 F1-2Overcurrent Limit Switch Hall Sensor1. The factory setting is “F1-0”.
F2Overcurrent for Gate OpeningF2-0 F2-1 F2-2 F2-3 F2-4 F2-5 F2-6 F2-7 F2-82A

3A

4A

5A

6A

7A

8A

9A

10A

1. The factory setting is “F2-1”.
F3Overcurrent for Gate ClosingF3-0 F3-1 F3-2 F3-3 F3-4 F3-5 F3-6 F3-7 F3-82A

3A

4A

5A

6A

7A

8A

9A

10A

1. The factory setting is “F3-1”.
F4Motor Speed for OpeningF4-0 F4-1 F4-2 F4-340%

50%

75%

100%

1. The factory setting is “F4-2”.
F5Motor Speed for ClosingF5-0 F5-1 F5-2 F5-340%

50%

75%

100%

1. The factory setting is “F5-2”
F6Deceleration SpeedF6-0 F6-1 F6-2 F6-340%

50%

60%

70%

1. The factory setting is “F6-1”.
F7Time Gap b/w Two Gates (Opening)F7-0 F7-1 F7-2 F7-3 F7-4 F7-5 F7-6 F7-7 F7-8 F7-90 sec

2 sec

5 sec

10 sec

15 sec

20 sec

25 sec

35 sec

45 sec

55 sec

1. The factory setting is “F7-1”.
SettingDefinitionParamtersTableDescription
 

 

 

F8

 

 

 

Time Gap b/w Two Gates (Closing)

F8-0 F8-1 F8-2 F8-3 F8-4 F8-5 F8-6 F8-7 F8-8 F8-90 sec

2 sec

5 sec

10 sec

15 sec

20 sec

25 sec

35 sec

45 sec

55 sec

 

 

 

 

1. The factory setting is “F8-1”.

 

 

F9

 

 

 

Auto-closing

F9-0 F9-1 F9-2 F9-3 F9-4 F9-5 F9-6 F9-7 F9-8Function OFF 3 sec

10 sec

20 sec

40 sec

60 sec

120 sec

180 sec

300 sec

1. Auto-close mode activates when the gates move to the end position or stopped manually. If thetransmitter,

push button, or the key selector is activated before the auto- close counting, the gate will close immediately.

2. The factory setting is “F9-0”.

 

FA

 

Safety Device Function Mode

FA-0

FA-1

FA-2

FA-3

Mode 1

Mode 2

Mode 3

Mode 4

1. Please see 7.3 photocell adjustment for photocell logic

2. The factory setting is “FA-0”.

FBPedestrian ModeFB-0 FB-1Function OFF Function ON1. The factory setting is “FB-1”.
 

FC

 

 

Flashing Light

 

FC-0 FC-1

 

Function OFF Function ON

1. When function FC-1, the light will flash for 3 seconds before the gate operates. If set OFF, the flash light will operate with motor at the same time.

2. The factory setting is “FC-0”.

FDPhotocell ActivationFD-0 FD-1Function OFF Function ON1. The factory setting is “FD-0”.
FEPhotocell 2 ActivationFE-0 FE-1Function OFF Function ON1. The factory setting is “FE-0”.
FFAlarm BuzzerFF-0 FF-1Function OFF Function ON1. The factory setting is “FF-0”.
 

FG

 

Electric Latch Mode

 

FG-0 FG-1

Standard Gate Opening Release Gate Tension before

Opening (Gate Reversing for 0.25s)

1. If the function is FG-1, the motor will be reversed for

0.25 sec. to release the tension.

2.The factory setting is “FG-1”.

 

 

 

FH

 

 

 

 

LED Direction

 

 

 

 

FH-0 FH-1

 

 

 

 

When Terminal Block is at Top When Terminal Block is at Bottom

1. The factory setting is “FH-1”. The UP( ) and Down( )

buttons will switch according to

the parameter setting.

When FH-0, button SW3 stands for            (UP), and button

SW5 stands for  (DOWN).

When FH-1, button SW5 stands for            (UP), and button SW3

stands for  (DOWN)

FIDual / Single GateFI-0 Fl-1Single Gate Dual Gate1. The factory setting is “FI-1”.
 

 

FJ

 

 

Over Current Reverses Time when Close

FJ-0

FJ-1

FJ-2

FJ-3

FJ-4

FJ-5

FJ-6

Function OFF

0.1 sec

0.2 sec

0.3 sec

0.4 sec

0.5 sec

0.6 sec

 

 

1. The factory setting is “FJ-0”

Note (F1-2 over-current setting in Hall sensor mode):

  • Only in “F1-2” Hall sensor mode, the PCB will record all the current values in learning mode. Please adjust over current value by setting the F3 function after learning mode.
  • The recorded current values will increase according to the value shown on the LED display over the current value.
  • The value can be adjusted by pressing the button UP and DOWN. The maximum value is 50(5.0A) and the minimum value is 05(0.5A). LED display example:
    • Indicate 1.0 ampere: all of the recorded values will increase by 1 ampere over the current value.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (24)
    • Indicate 0.6 amperes: all of the recorded values will increase by 0.6 amperes over the current value.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (25)
    • Indicate 2.8 amperes: all of the recorded values will increase by 2.8 amperes over the current value.TMT-AUTOMATION-CB19-Control-Box-For-Hermit-FIG-1 (26)

Photocell Logic

FA-0 Photocell OPEN/CLOSE (Standard set up)

Position of GateWhen safety devices are activated
Type of Safety DevicePH1

Photocell-CLOSE

PH2

Photocell-OPEN

Fully ClosedNo effectOpen not allowed
Fully OpenedReload automatic closing timeNo effect
Stop During MovingReload automatic closing timeOpen not allowed
ClosingOpenNo effect
OpeningNo effectClose

FA-1 Safety Edge

Position of GateWhen safety devices are activated
Type of Safety DevicePH1

Photocell-CLOSE

PH2

Safety Edge

Fully ClosedNo effectOpen not allowed
Fully OpenedReload automatic closing time
Stop During MovingReload automatic closing timeOpen/Close not allowed
ClosingOpenReverse to open for 2 seconds
OpeningNo effectReverse to close for 2 seconds

FA-2 Open Only Device (Vehicle detector)

Position of GateWhen safety devices are activated
Type of Safety DevicePH1

Photocell-CLOSE

PH2

Photocell-CLOSE

Fully ClosedNo effectOpen
Fully OpenedReload automatic closing time
Stop During MovingReload automatic closing timeOpen
ClosingOpenOpen
OpeningNo effectNo effect

FA-3 Double photocell set up

Position of GateWhen safety devices are activated
Type of Safety DevicePH1

Photocell-CLOSE

PH2

Photocell-OPEN/CLOSE

Fully ClosedNo effectOpen not allowed
Fully OpenedOpen for 2 seconds, when auto-closing is ONNo effect
Stop During MovingClose not allowedOpen not allowed
ClosingOpenNo effect
OpeningNo effectStop

Troubleshooting

Issue:Solution:Parts to look at:
 

 

 

No power on the board.

•          Power to the transformer is on and the connector block from the AC power leads to the transformer and the control board is wired correctly.

•          At the control board check the transformer white connector blocks are correctly plugged into the board and that the battery connector is equipped.

•          Check fuses are both working. * 15amp for stand-alone transformer.

•          Check there is 24vac into and out of the Control box fuse.

•          The batteries are connected to the control board and read higher than 24vdc if equipped.

•          Try removing optional extras such as beams and probes to see if

they are draining the power. And reset the control panel to default and test the motor operation.

•          Fuse

 

•          Transformer power

 

•          Loose wires

 

•          Incorrect wire contact at connector blocks

•          Short circuit in wiring between transformer and board

•          Battery

 

A single-arm activation isn’t working.

•          Check function setting is set correctly for a single arm. Fl-1 single gate mode. FB-1 Pedestrian mode to be ON. Using button B on the remote to operate the single gate.

•          Make sure the arm is connected to motor 1 and not motor 2.

•          Your remote is programmed in.

•          You have done a systems learning.

•          There is adequate power going to the board.

 

•          Motor connection

•          Function setting for single mode

 

 

 

Remotes or wireless keypad not working.

Re-program remotes by pressing the RF-Learn button on the control board.

•          You can program in several remotes or devices at a time however all signals need to be sent before the blue light goes off again.

•          Push the button fairly solid and hold it in for a whole second. The blue light should flicker.

•          If the blue light is on continuously without pressing the RF learn button it means the receiver is faulty and needs to be replaced.

•          The blue light will still flash when a remote that has not been programmed in is used. It will however not activate.

•          Reset the keypad. Do this by flicking off the front cover with a small screwdriver. Undo the 2 nuts, turn over, and repeat until left with the control board on the casing. Undo the 3 screws in the comer. Turn over the circuit board and there is a button there.

Hold it until you hear a beep. Try the keypad again and reassemble.

 

 

 

 

 

•          RF Learn button on the control board

 

 

Lights on the board but arm(s) not moving.

•          Check the LED3 and LED4 on the board are off, which is located on the button right of the board if it is on check the photocell connection and function.

•          Check that the battery is 24V+.

•          Make sure your connections aren’t loose.

•          The power input is feeding in 24V+.

•          The gate is free from any obstructions.

•          The arm is locked into place (A good way to test this is if you can move the gate freely, then it won’t work via the motors).

•          Try depowering and repowering the board.

•          If it still keeps glowing please call or email us. The receiver may need replacement.

 

 

 

 

•          The gate

•          Power sources

•          Arm wires

 

 

 

Gates remain open after systems learn/one arm stays open and the other one closed.

•          Ensure you have matched the + and – of each ram to the equivalent + and – motor symbols on the board.

•          Change the polarity connection of the positive(+) with the negative(-) of the motor if the gate both stay open instead of closed after the system learning.

•          Clear any obstructions to the gates.

•          Make sure that the arms are going no further than 100 degrees.

•          The function setting should be set for a double swing and not a single.

•          Check the LED display during the system learning showing the motor current, once the reading is too high check the installation or the gate condition.

•          Ensure the motors are locked in.

•          Increase the power amp settings by function setting F2 for open and F3 for close direction (mentioned above).

 
 

Gates not fully opening or closing

•          Ensure nothing is obstructing the gate or the arms.

•          If the gate is a bigger or heavier gate change the power settings using the F2 for open and F3 for close direction. You should not have to use the maximum power setting. This is intended for a 500kg double swing gate (or 250kg single).

•          Re-do the systems learn.

 
One gate opens part of the way/not at all•          Make sure you are pressing the top left-hand button. The other buttons do have their functions.

•          Check the FB function for pedestrian mode, set to FB-0 if you require the single gate to be fully open instead of partially open.

•          Both arms are wired onto the control board correctly. They should

identical. I.E. black, red. Black, red.

 
Remote/ keypad range is less than 20M•          Make sure the antenna is attached and screwed in on the control board.

•          Make sure nothing is obstructing the antenna such as the

power cable or motor cables.

 

Technical Specification

Main power supply230Vac/110Vac, 50Hz/60Hz
Back-up battery2pcs of batteries for emergency operation, 2.2A each
Receiver board433.92MHz; 200 transmitters memory
InstallationWall mounted vertically
Operating Temperature-20°C~+50°C
Dimension275mm * 195mm * 102mm

FCC

FCC Warning

This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s authority to operate the equipment. The device has been evaluated to meet general RF exposure requirements.

Documents / Resources

TMT AUTOMATION CB19 Control Box For Hermit [pdf] User Manual
2BCSY-TM4, 2BCSYTM4, tm4, CB19 Control Box For Hermit, CB19, Control Box For Hermit, Hermit

References

Leave a comment

Your email address will not be published. Required fields are marked *