User Manual for SHOWVEN models including: HC8200, HC8200 Sparkular Cyclone, Sparkular Cyclone, Cyclone

飓风喷花机使用说明书英文版

SHOWVEN Sparkular Cyclone - User manual | käyttöohje

SHOWVEN Sparkular Cyclone - IPA Pro Shop


File Info : application/pdf, 8 Pages, 179.84KB

PDF preview unavailable. Download the PDF instead.

Sparkular Cyclone Manual
SPARKULAR Cyclone USER MANUAL
V1.1
Showven Technologies Co.,Ltd.

SPARKULAR Cyclone User Manual
®Please read this manual carefully before operating this product. ®Warranty card attached in the manual, please keep it well.
> Safety Considerations
vNever touch the nozzle of SPARKULAR Cyclone, danger of getting burnt. vNever touch the sparks which shooting out from the nozzle. vCover of nozzle of SPARKULAR Cyclone is prohibited. vKeep audience, animals or flammable objects at a minimum distance of 3m from SPARKULAR Cyclone. Make sure sparks shoot out from SPARKULAR Cyclone can NOT touch any objects in the air. vEnsure that children, animals and unauthorized persons don't have access to the SPARKULAR Cyclone! vUnauthorized repair are prohibited, it may cause serious incident. vKeep SPARKULAR Cyclone dry and do NOT use in rain or snow. vMake sure lid of feeding hopper are well covered when use SPARKULAR Cyclone. Accidentally burning of Composite
Ti can only use sands to extinguish. Composite Ti should keep away from moisture and stored in a dry sealed environment. v please be noted that there may sparks or remains fall to the ground when use HC8200 LARGE, LARGEú/û/ü. vClear material is necessary both before and after the show. Please check nozzle of SPARKULAR Cyclone after each show, if there are consumable agglomerated in the nozzle, please clear it with screwdriver, otherwise it will affect the spark effects and even damage the machine. vMaximum cascade of SPARKULAR Cyclone is 2 units with one standard power cable. Otherwise it may damage the machine and even cause fire. For 110V version SPARKULAR Cyclone, we suggest each machine connect to power supply directly. vFor better heat dissipation, block the air intake and air outlet is prohibited.

Model Dimension Weight Input
Work Temp. Effect height
Height adjustable Effect direction Hopper capacity HC8200 consumption Interface Control
1

BT61/BT62 457 x370 x 280mm 25kg AC 220VAC-240VAC,50/60HZ; 1700W AC 100VAC-120VAC,50/60HZ; 1700W -20°C~50°C HC8200 LARGE ü: 9-10m / HC8200 LARGEû: 8-9m HC8200 LARGEú: 7-8m / HC8200 LARGE : 6-7m Yes, gear 1~10 Straight up 500g 75g/min NEUTRIK POWERCON TRUE1, 3-pin and 5-pin XLR DMX

SPARKULAR Cyclone is a brand new product with SHOWVEN original technology. It is with amazing sparks effect up to 10m and equipped with auto brake system, ensure immediate stop even in max output. SPARKULAR Cyclone with waterproof design allows shows not interrupted by rain. It is designed for the high demanding professional show market makes it an ideal choice for large shows, concerts, music festival, outdoor events etc.
> Operating Panel
LED display area:
READYTurns from flashing into long on, indicates that the machine is ready to work. DMXFlashing shows that DMX signal is connected, light OFF means there is no DMX signal FAULTLight ON when error occurs HEATLight ON when system is heating up
Control Button Area:
MENU: switch through setup menu. Press 3s switch to advanced interface DOWN: parameter down UP: parameter up ENTER: confirm and save parameters
Radio Frequency Identification Area:
RFID card comes together with HC8200. It is a safety design, allows machine to identify the parameter and types of consumable. Please note that granules RFID card can increase the single machine specific working time. The card is disposable, can only use once.
2

> Interface
Main interface

First line: shows DMX address Second Line: shows inner temp. and temp. bar, as well as error info if available

Error Information
Error Information E0 System IC E2 Temp. Sensor E3 P Temp. Over E4 Time Remain E5 K Temp. Over E6 Heat Fail

Explanation Systematic error Temperature sensor is not connected or damage Chassis over-temperature Activated time for machine is not enough, need to swip RFID card Inner core over-temperature Heating Fail, if it recovery automatically, problem is shortage of power supply

Setting Menu Press "MENU" switch through setup menu

Set DMX Address

1-512

Set DMX address If controlled by Host Controller, please set DMX address as 1, 3, 5, 7,...2n-1, otherwise it may leads to signal interference

Manual Fountain Fountain Height Auto Clear Delay

On/Off 1-10 0.1-0.9s

Manual firing, for test only Manual firing height setup, for test only Auto clear material time after each firing

3

Advanced Menu
Press "MENU" 3 seconds to enter the advanced setup interface, press MENU key to enter different options, wait 3 seconds to return to the main interface.

Option Set Temperature LCD Backlight

Range 580-620 On/Off

Explanation Default is 580. Please don't change default value without engineer's suggestion from SHOWVEN.
LCD screen backlight ON/OFF

Density@ Height 1

80

Density@ Height 2

80

Density@ Height 3

80

Sparks density @ Height gear 1 Sparks density @ Height gear 2 Sparks density @ Height gear 3

Density@ Height 4

80

Density@ Height 5

80

Sparks density @ Height gear 4 Sparks density @ Height gear 5

Density@ Height 6

100

Density@ Height 7

100

Density@ Height 8

100

Sparks density @ Height gear 6 Sparks density @ Height gear 7 Sparks density @ Height gear 8

Density@ Height 9

40-100

Sparks density @ Height gear 9

Density@ Height 10 40-100

Sparks density @ Height gear 10

Mode Selection

Factory Mode User Mode

Factory mode is for engineer only. When in Factory mode machine can't controlled by DMX console/host controller

Motor Protect Standby Switch

On/Off On/Off

Motor protect function, default setting is Off
When ON, the machine can firing only when heating up was finished

For better performance of SPARKULAR Cyclone, please don't change the default value of density without permission from SHOWVEN.

4

SPARKULAR Cyclone occupy 2 channels

First Channel

Function

0-15

Firing OFF

16-255

Firing ON and with adjustable height

Second Channel

Funciton

60-80 20-40

Firing ON and with adjustable height Emergency Stop

0-10

Pre-heat OFF (disabled when auto-heat ON)

240-255

Pre-heat ON (disabled when auto-heat ON)

Please follow bellowing rules to set DMX address when use SHOWVEN Host Controller, otherwise it may leads to signal interference.

Sparkular No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 DMX Address 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35

5

Warranty Instructions
·Sincere thanks for your choosing SPARKULAR Cyclone, you will receive quality service from us. ·The product warranty period is one year. If there are any quality problems within 7 days after ship
ping out from our factory, we can exchange a brand new same model machine for you. ·We will offer free of charge maintenance service for machines which with hardware malfunction
(except for the instrument damage caused by human factors)in warranty period. Please don't repair machine without factory permission.

®Below situations NOT included in warranty service: 1. Damage caused by improper transportation, usage, management, and maintenance, or damage
caused by human factors; 2. Disassemble, modify or repair products without Showven's permission; 3. Damage caused by external reasons (lightning strike, power supply etc); 4. Damage caused by improper installation or use; For product damage not included in warranty range, we can provide paid service. ®Invoice and warranty card are necessary when applying for maintenance service from SHOWVEN.
Warranty Card

Product Name: Purchase Date:
Tel:
Address:
Problem Feedback
Actual Problem: Maintenance Detail: Service Engineer:

Serial No. Service Date:

6

Showven Technologies Co., Ltd
Add: Building B1, Changsha E Center No.18, Xiangtai Road, Liuyang Economic Development Zone, Changsha City, 410300, Hunan Province, P.R.China. Tel: +86-731-83833068 Web: www.showven.cn E-mail: info@showven.cn



References

Adobe Illustrator CC (Windows) 3-Heights™ PDF Optimization Shell 6.3.1.5 (http://www -tools.com)