User Guide for Vent-Axia models including: 438342 Lo Carbon Sentinel Kinetic BH, 438342, Lo Carbon Sentinel Kinetic BH, Sentinel Kinetic BH, Kinetic BH
Vent-Axia - Ventilation, Heating, Hygiene and Cooling
Lo-Carbon Sentinel Kinetic BH · Recognised in SAP PCDB · Lightweight for easier installation · Horizontal duct option for space-saving installations · Fits within a 290mm deep kitchen cupboard · Integrated digital controller for simple and accurate commissioning · Plug and play controls; Humidistat, Wireless Remote · BMS connectivity · LS inputs (Light Switch) · Horizontal duct options · Acoustic Enclosure option for reduced breakout noise · Acoustic Top Box option for reduced in-duct noise Easy Installation The Sentinel Kinetic models can be mounted vertically in a roof space, hallway cupboard or kitchen or within a kitchen cupboard. When mounted in an unheated area ducting and MVHR unit should be insulated. Ducting can be attached to the unit horizontally, vertically or both. Minimum internal depth of kitchen cupboard 290mm. For scenarios where noise is a critical issue, an Acoustic Enclosure is available to reduce breakout noise and the Acoustic Top Box will reduce in-duct noise at key frequencies. Left (L) or right (R) hand installation. The unit is supplied with duct spigots to outside on the right hand side. These can be reversed on site by simply removing the control panel, rotating the unit 180 degrees and re-attaching the control panel. Spigot Options The combination of spigot options allows installation in confined locations. If vertical and horizontal connection is required on the same outlet/inlet, additional spigots can be supplied. The condensate drain can be taken out through the back, side or bottom of the unit. Using the fittings supplied, the final condensate connection is made outside the unit and can be completed after installation. Integral Humidity Sensor (BH Models) The integral humidity sensor increases speed in proportion to relative humidity levels, saving energy and reducing noise. The sensor also reacts to small but rapid increases in humidity, even if the normal trigger threshold is not reached. This unique feature ensures adequate ventilation, even for the smallest wet room. The night time relative humidity setback feature suppresses nuisance tripping as humidity gradually increases with falling temperature. Models Model Kinetic VS Right Kinetic BH Right Kinetic BH Right with Acoustic Enclosure & Top Box Kinetic BH Right with Acoustic Top Box Kinetic BH Right with Acoustic Enclosure Kinetic BH Left Kinetic BH Left with Acoustic Enclosure & Top Box Kinetic BH Left with Acoustic Top Box Kinetic BH Left with Acoustic Enclosure (BH with summer bypass & humidity sensor) Stock Ref 438342 443319 479526 479525 479524 443319L 479529 479528 479527 Accessories Model Wired Remote Controller LED alarm with 15m cable Acoustic Purge Fan Acoustic Purge Fan XL ISO 45% Coarse (G3) 2x Filter ISO ePM10 50% Pollen (M5) 1x Filter Anti Vibration Mounts Stock Ref 443283 448356 477988 479829 442356 444199 68MP033G SAP PCDB performance (Kinetic VS) SAP 2009 SAP 2012 Thermal Thermal Efficiency % SFP (W/l/s) Efficiency % SFP (W/l/s) K+1 90 0.60 90 0.61 K+2 90 0.59 90 0.74 K+3 90 0.68 90 0.95 K+4 89 0.79 90 1.19 K+5 90 0.97 - - SEC Class Model Kinetic VS & BH Dimensions (mm) Unit EØ D F SEC Class A A C G B A B C D EØ F G 550 550 285 140 125 360 90 Weight: 15kg Acoustic Solution Top Front D C Side Acoustic Top Box Performance Fan speeds are fully adjustable within the performance range. Vertical Spigots 400 100% 80% 300 Static Pressure (Pa) 60% 200 128 96 40% 100 20% 13 0 53 107 82 27 44 58 20 30 l/s 0 10 20 30 40 50 60 70 m3/h 0 50 100 150 200 250 Volume Horizontal Spigots 100% 400 80% 300 80 300 Static Pressure (Pa) 200 60% 40% 100 20% 0 12 118 89 49 26 18 25 38 54 75 97 l/s 0 10 20 30 40 50 60 70 m3/h 0 50 100 150 200 250 Volume x figure relates to Wattage (both motors) B Acoustic Enclosure A E F G Acoustic Acoustic Top Box Enclosure A B C D E F G kg kg Spigot 80 633 501 75 626 447 45 11 19 125 Sound Data (Kinetic VS & BH) Sound Data (Kinetic VS & BH with Acoustic Solution) Octave band, Hz, dB SWL SPL dB(A) Speed Test mode 63 125 250 500 1k 2k 4k 8k LwA @ 3m Supply 52.9 52.9 46.5 41.7 39.3 29.3 19.3 22.8 44.4 26.9 20% Extract 50.7 41.9 37.4 34.5 29.8 17.7 17.4 22.7 35.7 18.2 Breakout 36 34.5 33.6 34.3 33.8 27.2 22.2 25.3 37.2 16.7 Supply 57.1 64.1 56.8 50.6 49.7 41.1 32.8 26.4 54.7 37.2 40% Extract 55.2 50.3 44.9 43 38.3 27.7 19.8 22.9 43.8 26.3 Breakout 43.5 41.7 40.4 41.3 41.7 36.1 27.8 26.2 44.7 24.2 Supply 71.3 72.5 68.5 57.6 56.4 51.1 42.7 38.1 63.6 46.1 60% Extract 60.2 56.3 52 48.8 44.8 35.5 26.9 24.4 50.2 32.7 Breakout 50.7 47.8 47.7 47.7 48.3 44.9 36.7 30 51.8 31.3 Supply 66.3 74.8 71.2 62.8 61 56.3 49.8 46.7 67.3 49.8 80% Extract 63.8 59.4 57.6 53.8 49.2 41.2 33.5 29 55.0 37.5 Breakout 54.4 52.7 54 52.7 53.5 50.3 43.6 37.7 57.2 36.7 Supply 70.3 75.7 73.9 66.3 63.5 59.7 53.2 50.6 70.0 52.5 100% Extract 66.6 63.9 60.9 56.5 51.2 44.2 36.8 32.6 57.9 40.4 Breakout 59.1 55.2 56.8 55.6 56.1 53.5 47.1 41.6 60.1 39.6 Octave band, Hz, dB SWL SPL dB(A) Speed Test mode 63 125 250 500 1k 2k 4k 8k LwA @ 3m Supply 57.1 44.6 36.4 27.9 20.6 14.8 18.1 23.8 35.2 17.7 20% Extract 54.4 40.1 29.6 22.2 17.5 14.5 17.8 23.5 31.1 13.6 Breakout 37.5 33.8 29.1 22.9 17.0 14.0 17.8 23.6 27.7 7.2 Supply 64.9 56.3 46.4 36.1 28.2 15.4 18.1 23.8 44.6 27.1 40% Extract 60.2 46.8 35.7 28.2 21.9 14.8 18.1 23.7 36.6 19.1 Breakout 46.0 43.6 36.3 30.4 23.9 15.9 18.1 23.6 33.5 13.0 Supply 72.3 63.0 55.6 43.1 34.1 19.5 18.6 24.0 51.9 34.4 60% Extract 61.4 53.3 43.4 34.7 27.2 15.5 18.1 23.8 41.4 23.9 Breakout 52.2 50.5 44.4 38.2 33.5 23.8 19.3 23.8 41.0 20.5 Supply 73.8 67.9 61.6 50.0 38.6 23.4 20.2 25.2 56.8 39.3 80% Extract 68.6 58.2 50.5 40.5 31.1 17.2 18.2 23.9 47.5 30.0 Breakout 65.6 55.5 50.5 43.8 39.7 32.7 24.9 24.0 47.4 26.9 Supply 77.3 70.8 64.9 53.8 41.4 26.3 21.9 26.8 60.1 42.6 100% Extract 71.5 60.6 53.5 43.9 33.4 19.1 18.5 24.0 50.5 33.0 Breakout 69.0 58.4 53.4 47.1 43.0 37.5 29.9 24.9 51.1 30.6 Tested according to BS EN 13141-7:2010. Breakout quoted spherical. Supply and Extract quoted hemispherical. For in-duct data, end reflections are added based on the spigot size of the unit.Adobe PDF Library 17.0 Adobe InDesign 18.3 (Windows)