Installation Guide for tp-link models including: LS1016G, LS1016G 24-Port Gigabit Desktop Rackmount Switch, 24-Port Gigabit Desktop Rackmount Switch, Gigabit Desktop Rackmount Switch, Desktop Rackmount Switch, Rackmount Switch, Switch

7106511761 LS1016G(UN)1.0多机型 IG电子版

Download

LS1016G(UN) V1.0 Multi-model Installation Guide | Omada Network Support BookmarksCopy Link

Installation Guide - TP-Link

2 days ago —

Installation Guide


File Info : application/pdf, 2 Pages, 507.44KB

PDF preview unavailable. Download the PDF instead.

LS1016G(UN)1.0 Multi-model IG
© 2024 TP-Link 7106511761 REV1.0.0

Installation Guide
16/24-Port Gigabit Desktop/Rackmount Switch LS1016G/LS1024G
For simplicity, we will take LS1024G for example. The images are for demonstration only and may differ from your actual product.
LEDs Power
On: The switch is powered on. Off: The switch is powered off or power supply is abnormal. Flashing: Power supply is abnormal/Loop Prevention function is enabled. Link/Act On: A device is linked to the corresponding port and running properly. Off: No device is linked to the corresponding port. Flashing: Transmitting or receiving data.

Appearance
Front Panel

LEDs
Rear Panel

10/100/1000 Mbps RJ45 Ports

Grounding Terminal

Power Socket

Others
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable.
Power Socket Plug the female connector of the power cord directly into the power socket and plug the male connector into an AC outlet. Make sure that the voltage of the power supply meets the requirement of the input voltage (100­240 V ~ 50/60 Hz).

Installation
Method 1: Desktop Installation
Feet Bottom of the Device Notch
1) Remove the adhesive backing papers from the feet. 2) Attach the feet to the bottom of the switch to prevent it from slipping when placed on a desktop.
Connection

Method 2: Rack Installation

Rack-mounting Bracket Screw

Rack

Note: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Place the device with its bottom facing downwards. Mount devices in sequence from the bottom to top of the rack and ensure a certain clearance between devices for the purpose of heat dissipation.

AC Power Cord

Router/Gateway

WAN Port

LAN Port

Internet

Ethernet Ports

PC

PC

Specifications

General Specifications

Standard Protocol Interface
Network Media (Cable)
Switching Capacity Transfer Method MAC Address Learning Frame Forwarding Rate

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3x, IEEE802.1p
CSMA/CD
16/24 10/100/1000 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
10Base-T: 2-pair UTP/STP of Cat. 3 or above (maximum 100 m) 100Base-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000Base-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m)
LS1016G: 32 Gbps LS1024G: 48 Gbps
Store-and-Forward
Automatically learning, automatically aging
10Base-T: 14881 pps/Port 100Base-X: 148810 pps/Port 1000Base-T: 1488095 pps/Port

Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the Power LED is not lit, check as follows: A1: Make sure the power adapter is connected to the switch with power source properly. A2: Make sure the voltage of the power supply meets the requirements of the input voltage of the switch. A3: Make sure the power source is ON.
Q2. The Link/Act LED is not lit when a device is connected to the corresponding port.
It is recommended that you check the following items: A1: Make sure that the cable connectors are firmly plugged into the switch and the device. A2: Make sure the connected device is turned on and works normally. A3: The cable must be less than 100 meters long (328 feet).
Q3. Why does the switch fail to detect and block a loop from occurring in the network topology when Loop Prevention is enabled?
A: When this switch is connected to other non-terminal devices, such as switches of other brands, and the device is incapable of correctly processing or forwarding loop detection packets, the Loop Prevention function will be limited. It is recommended to connect the terminal devices directly to this switch or connect non-terminal devices with complete forwarding capability to this switch.

Safety Precautions

To avoid any device damage and bodily injury caused by improper use, you should observe the following rules. Keep the power off during the installation. Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is well grounded. Use only the power cord provided with the switch. Make sure that the supply voltage matches the specifications indicated on the rear panel of the switch. Ensure that the switch is installed in a well-ventilated environment and its ventilation hole is not blocked. Do not open or remove the cover of the switch. Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never use any other liquid cleaning method. Place the device with its bottom surface downward.
Lightning Protection

Site Requirements
Temperature/Humidity

Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the following table.

Environment Temperature

Humidity

Operating Storage

0 °C to 50 °C (For LS1016G) 0 °C to 45 °C (For LS1024G) -40 °C to 70 °C

10% to 90%RH Non-condensing 5% to 90%RH Non-condensing

Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000 °C. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken. Ensure that the rack and the device are well earthed.
Make sure the power socket has a good contact with the ground. Keep a reasonable cabling system and avoid induced lightning. Use the signal SPD (Surge Protective Device) when wiring outdoor. Note: For detailed lightning protection measures, refer to the Lightning Protection Guide: https://www.tp-link.com/us/configuration-guides/lightning_protection_guide
Installation Site

Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact of metal contact points. Some measures have been taken for the device to prevent static electricity, but too strong static electricity can cause deadly damage to the electronic elements on the internal circuit board. To avoid the effect of static electricity on the operation of the switch, attach much importance to the following items:
Dust the device regularly, and keep the indoor air clean. Keep the device well grounded and ensure that the static electricity has been transferred. Electromagnetic Interference

When installing the device on a rack or a flat workbench, attach much importance to the following items:
The rack or workbench is flat, stable, and sturdy enough to support the weight of 5.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.

Environmental and Physical Specifications

Certification

FCC, CE, RoHS

Operating Temperature

0°C to 50°C (32°F to 122°F) (For LS1016G)

0°C to 45°C (32°F to 113°F) (For LS1024G)

Storage Temperature

-40°C to 70°C (-40°F to 158°F)

Operating Humidity

10% to 90%RH non-condensing

Storage Humidity

5% to 90%RH non-condensing

EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863. The original EU declaration of conformity may be found at https://www.tp-link.com/en/ce.
UK declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment (Safety) Regulations 2016. The original UK declaration of conformity may be found at https://www.tp-link.com/support/ukca/

Electronic elements including capacitance and inductance on the device can be affected by external interferences, such as conducted emission by capacitance coupling, inductance coupling, and impedance coupling. To decrease the interferences, make sure to take the following measures:
Use the power supply that can effectively filter interference from the power grid. Keep the device far from high-frequency and strong-current devices such as radio transmitting station. Use electromagnetic shielding when necessary.
To ask questions, find answers, and communicate with TP-Link users or engineers, please join TP-Link Community. For technical support and other information, please visit https://www.tp-link.com/support/?type=smb, or simply scan the QR code.
Safety Information
Keep the device away from water, fire, humidity or hot environments. Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us. Place the device with its bottom surface downward. The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be easily accessible. The socket-outlet shall be installed near the equipment and shall be easily accessible Plug the product into the wall outlets with earthing connection through the power supply cord.
Please read and follow the above safety information when operating the device. We cannot guarantee that no accidents or damage will occur due to improper use of the device. Please use this product with care and operate at your own risk.



References

Adobe PDF library 15.00 Adobe Illustrator 24.1 (Windows)