Laserliner - logoCondense Spot XP
Manual UserLaserliner Condense Spot XPLaserliner Condense Spot XP 2

Laserliner Condense Spot XP - icon 2Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference.

Function/Application

The CondenseSpot is an infrared temperature measuring instrument with an integrated hygrometer that permits non-contact temperature measurements on surfaces as well as the measurement of relative humidity and ambient temperature. The instrument measures how much electromagnetic energy is emitted in the infrared wavelength range and uses this information to calculate surface temperature. During this process, two additional integrated sensors detect relative humidity and ambient temperature. The dew point is also calculated.

Laserliner Condense Spot XP - figure 1Laserliner Condense Spot XP 3

1 low battery charge 6 min/max and average measurement values
2 stability progress bar for relative
humidity measurement
7 dew point temperature (D Temp) and ambient temperature  (A Temp) in °C or °F
3 laser beam switched on, temperature measurement (infrared) 8 condense water indicator
4 measurements in °C or °F 9 last measurement value will be displayed brie y (7s)
5 relative humidity in % 10 replace battery

Laserliner Condense Spot XP 4Laserliner Condense Spot XP 5

Laser: The laser is a targeting aid to sight the location for the infrared measurement. Only the surface‘s temperature is measured. Laserliner Condense Spot XP 6

7. Displaying Min/Max/Avg, Ambient temperature, Dew point temperatureLaserliner Condense Spot XP 7

8. Dew point temperature is the temperature at which current air conditions would produce condensation. The CondenseSpot calculates the dew point temperature from ambient temperature, relative humidity, and ambient atmospheric pressure. In combination with the infrared thermometer, thermal bridges are easily detected. If the temperature of the measured location drops below the dew point, condensation (water) will form on the surface.Laserliner Condense Spot XP 8

9. Kamag-anak halumigmig
The relative humidity is indicated in relation to the maximum possible humidity (100 %) at which air forms water vapor. The ability of air to hold water is temperature-dependent. Thus humidity is the volume of water vapor in the air. The range for humidity is 0 … 100%. 100% = saturation point.
Under these conditions for temperature and atmospheric pressure, air cannot absorb any more water.Laserliner Condense Spot XP 9

When temperature fluctuations (± 1 °C) and/or changes to relative humidity (± 1%) are rapid, the sensor must adapt itself to the new conditions. An hourglass with a progress bar is displayed during this stabilization process.
During this process, displayed values are only approximations. Only after these symbols have been switched off is a stable value presented which represents maximum accuracy.

10. Setting the emission coef cientLaserliner Condense Spot XP 10

A built-in sensor head detects the material/surface-specific infrared rays emitted by every object. The level of these emissions is determined by the material‘s emission coefficient (0.01 to 0.99). This instrument is preset to an emission coefficient of 0.95, which is applicable to most organic materials as well as plastics,  ceramics, wood, rubber, and stone. For details of those materials with a different emission coefficient, please refer to the table.

Hindi kilalang emission coefficient:
Apply masking tape or black matt paint to the surface of the area whose temperature you wish to measure. Wait until the tape/paint has heated up.
The temperature of the surface can then be measured with an emission coefficient of 0.95.

11. Emission coef cient tables
Mga Nonmetal

Asbesto 0.93 Limestone 0.98
Ispalto 0.95 Marmol
Black, dull finish Greyish, polished
0.94
0.93
Basalt 0.70
Brick, pula 0.93
Carborundum 0.90 Kanterya 0.93
keramika 0.95 Pintahan
Itim, matt
Heat-resistant White
0.96-0.98 0.92
0.85-0.95
Tsina
Brilliant white With glaze
0.7 - 0.75 0.92
Luad 0.95 Papel
Lahat ng mga kulay
0.95-0.97
Coal Non-oxidised 0.8-0.9
plastik
Translucent PE, P, PVC
0.95
0.94
Concrete, plaster, mortar 0.93
Cottonwood 0.77 Goma
Mahirap
Malambot, kulay abo
0.94-0.95 0.89
Lupa, matt 0.93
Tela 0.95
salamin 0.85-0.94 Quartz na baso 0.93
grapayt 0.7-0.8 Snow 0.80
graba 0.95 Lupa 0.9-0.98
Gypsum 0.8-0.95 Tar 0.79-0.84
Heat sink Itim, anodized 0.98 Papel na tar 0.91-0.93
Pintura ng transformer 0.94
Balat ng tao 0.98 Wallpaper, light-colored 0.88-0.90
yelo
malinaw
Na may mabigat na hamog na nagyelo
0.97
0.98
tubig 0.93
Kahoy
Hindi ginagamot
Beech, planado
0.8 -0.95 0.94
dayap 0.3-0.4
Lime maim brick 0.95

Mga Metal

Alloy A3003 Oxidised
Magaspang
0.3
0.1 - 03
Bakal, huwad na Matt 0.9
Pangunahan
Magaspang
Na-oxidized
0.4
0.2 - 0.6
Aluminium Oxidised
makintab
0.2 - 0.4
0.04 - 0.06
Molybdenum Oxidised 0.2 - 0.6
tanso
makintab
Na-oxidized
0.3
0.5
Nickel Oxidised 0.2 - 0.6
Platinum Itim 0.9
Tanso
Na-oxidized
Elect. terminal strips
0.4 - 0.8 0.6 bakal
Cold rolled Ground plate
Pinakintab na plato
Alloy (8% nickel,
18% chromium) Galvanised Oxidised
Napaka-oxidized
Freshly rolled Rough, flat surface
Kinakalawang, pula
Sheet, nickel-plated Sheet, rolled
0.7 - 0.9 0.4 - 0.6 0.1
0.35
0.28
0.80
0.88
0.24
0.95- 0.98 0.69
0.11
0.56
Haynes Metal alloy 0.3 - 0.8
Inconel
Na-oxidized
Sandblasted Electropolished
0.7 - 0.95 0.3 - 0.6 0.15
Bakal
Na-oxidized
May kalawang
With red rust
0.5 - 0.9 0.5 - 0.7 0.61 - 0.85
Bakal, cast
Na-oxidized
Non-oxidised
Natunaw na masa
0.6 - 0.95 0.2
02 - 03
Zinc Oxidised 0.1

Teknikal na data

Technical revisions reserved. 08.13

Measured quantities °C (°F) infrared temperature measurement, %rH relative humidity, °C (°F) ambient temperature measurement
Infrared measurement range -40 °C … 350 °C (-40 °F … 662 °F)
Saklaw ng pagsukat ng temperatura sa paligid -10 °C … 60 °C (14 °F … 140 °F)
Relative humidity measurement range 20 % … 90 % rH
Dew point indicator -20 ° C… 60 ° C
Katumpakan ng infrared t 1 °C (-10 °C … 60 °C); t 1.5 °C (< 10 °C and > 60 °C) or t 1.5 % whichever value is greater
Ambient temperature accuracy t 2 °C
Relative humidity accuracy t 3%
Infrared resolution 0.1 ° C
Relative humidity resolution 1%
Dew point resolution 1 ° C
Koepisyent ng paglabas Adjustable, 0.10 … 0.99
Operating temperatura 0 ° C… 40 ° C
storage temperatura -20 ° C… 70 ° C
Optika 8:1 (distance: measured spot)
Laser haba ng daluyong 650 nm
Laser uri Class 2, < 1 mW
Power supply ng Type 9 V E block battery

General safety instructions.
Attention: Do not look directly into the laser beam! The laser may not get into the hands of children! Do not point this device unnecessarily toward persons.Laserliner Condense Spot XP - warning

Mga direktiba at pagtatapon ng EU
Laserliner Condense Spot XP - ce
Sumusunod ang device na ito sa lahat ng kinakailangang pamantayan para sa libreng paggalaw ng mga kalakal sa loob ng EU.
Ang produktong ito ay isang de-koryenteng aparato at dapat na kolektahin nang hiwalay para sa pagtatapon ayon sa European Directive sa mga basurang elektrikal at elektronikong kagamitan.
Karagdagang kaligtasan at mga karagdagang paunawa sa: www.laserliner.com/info
CondenseSpotLaserliner Condense Spot XP - CondenseSpot

Laserliner Condense Spot XP - iconSERVICE
Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
[protektado ng email]
Umarex GmbH & Co KG
Thunder field 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
Laserliner - logoLaserliner Condense Spot XP - ce

Mga Dokumento / Mga Mapagkukunan

Laserliner Condense Spot XP [pdf] Manwal ng Gumagamit
Condense Spot XP

Mag-iwan ng komento

Ang iyong email address ay hindi nai-publish.