Heavenly Heat Traditional Sauna Heater Installation
Overview
- Install junction box.
- Direct connect junction box to electrical panel.
- Run 3/4 in. metallic conduit from junction box to heater.
- Mount heater.
- Mount thermostat bulb.
Requirements
- It needs a 2 pole 30 amp non-GFCI breaker.
- Run (2) #10 copper wires + ground to heater.
- Wires connect to heater terminals 1 and 2.
Electrician to Provide
- Junction box.
- 3/4 in metallic conduit.
- All wiring external sauna heater.
Heater Connection
Image shows a close-up of electrical connections within a junction box. Red, green, and brown wires are visible, connected to screw terminals.
Exterior Installation
Install Junction box (provided by electrician) on outside of the back wall of the sauna next to the predrilled hole.
Use 3/4 in. metallic conduit from the junction box to the sauna heater (provided by electrician). Route metallic conduit through pre-drilled holes on the back wall and sitting baffle.
Diagram illustrating the exterior back of the sauna. A junction box is shown mounted externally, next to a pre-drilled hole. Arrows indicate a direct connection to the electrical panel and the routing of 3/4 inch metallic conduit through pre-drilled holes in the back wall and sitting baffle towards the heater.
Heater Mounting
Step 1
Remove 2 screws to release black mounting plate from silver mounting bracket.
Image shows a close-up of a heater's mounting hardware. A black mounting plate is shown attached to a silver mounting bracket, with screws visible.
Step 2
Slide black mounting plate away from heater.
Image shows a hand sliding a black mounting plate away from the heater unit.
Step 3
Remove black hanging bracket from bottom of heater.
Image shows the bottom of the heater unit. A black hanging bracket is attached, with an arrow pointing to it labeled 'Remove'.
Step 4
Mount black hanging bracket to wall with screws included in warning sign bag that was in heater box.
Two diagrams provide precise mounting measurements for the hanging bracket: '3.5 inches from side of back plate to trim on side wall' and '6.75 inches from the bottom of back plate to top of trim on floor'.
Image shows the black hanging bracket being mounted to a wall surface.
Step 5
Once mounting plate is attached to the wall, the heater can be placed back on the bracket bars by inserting the bar ends back into the holes in the bottom of the heater.
Image shows the heater unit being positioned to be placed back onto the mounting bracket bars, with the ends of the bars aligning with holes on the bottom of the heater.
Step 6
Place the silver mounting bracket back on top of the heater.
Image shows a hand placing the silver mounting bracket back onto the top of the heater unit.
Step 7
Screw the mounting bracket back to the black mounting plate.
Image shows the silver mounting bracket being secured to the black mounting plate with screws.
Thermostat Bulb
The KV Topclass heater has a temperature sensor bulb attached to a coil of wire. This bulb needs to be run up the face of the sauna wall ideally 12" down from the ceiling. A mounting bracket is included in the heater box, usually attached to the heating elements with a zip tie. To locate the sensor bulb remove the side cover under the control knobs. The thermostat bulb connected to a coil of wire is tucked between the control consul and the main heater body.
Two images illustrate the thermostat sensor bulb and wiring. The first shows a hand holding the temperature sensor bulb and its wire, labeled 'Temperature Sensor bulb' and 'Thermostat wire'. The second image shows the thermostat wire tucked between the control console and the main heater body, labeled 'Thermostat wire'.
Depending on if you have controls on the left of right side of the heater the coil of wire could be found at the front of the heater or hidden on the back side of the heater against the wall.
Installation
Run the thermostat wire up the wall and away from the heater at least 12 inches. The bulb should be mounted 12" - 24" from the ceiling of the sauna. Cover the thermostat wire with the wooden cover provided with the heater.
Diagram shows a sauna interior with a white line indicating the thermostat wire routed vertically up the wall from the heater, away from the ceiling.