TCL Window Air Conditioner Warranty IMITED WARRANTY-North America Should your TCL Window Air Conditioner prove to be defective…
Scan or text a photo of the camera icon to 71403
Or register online at register.tcl.com
Need help? Visit photoregister.com/help or text HELP to 71403
Add a TCL Protection Plan when you register your product and be covered from life’s mishaps
Thank you for choosing TCL. We want your ownership experience to bring you as much joy as the product you purchased does, so we’re offering you a special price on TCL Protection Plans when you purchase during registration. Add a TCL Protection Plan within your first 30 days of ownership to receive the best value and we’ll make sure nothing gets in the way of you enjoying your new product.
*Extended service plans (i.e., “Protect” and “Plus” plans) are only offered in the United States (US). All TCL products continue to offer a limited consumer warranty in both the US and Canada. Please refer to the warranty section in this guide for additional details on warranty information.
Before installing and using your air conditioner, please read this owner’s manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this owner’s manual.
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow the following basic precautions:
ELECTRICAL REQUIREMENTS
The electrical ratings for your air conditioner are listed on the model and serial number label located on the front right hand side of the unit (when facing the front).
REGISTER YOUR APPLIANCE
You can register your appliance online by going to register.tcl.com
Be sure to retain your original sales receipt. A valid proof of purchase is required for all warranty claims.
BATTERY WARNING STATEMENT
Do not mix old and new batteries and do not mix alkaline, standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc.) batteries
Document your model and serial numbers here:
Model #___________________________________
Serial #___________________________________
You can locate your 20 digit serial number underneath the bar code (On the right hand side of the AC).
WARNING | Specific electrical requirements are shown in the diagram below. Follow the requirements below for the type of plug on the power supply cord. | |
Electrical Shock Hazard Plug into a grounded 3 prong outlet. Do not remove the ground prong. Do not use an adapter Do not use an extension cord. Failure to follow these instructions can result in death, fire, or electrical shock | Wiring Requirements | Power Supply Cord |
|
RECOMMENDED GROUND METHOD
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the customer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
The distance between user and device should be no less than 20cm.
DO NOT RETURN TO STORE
WE ARE READY TO HELP
contact us first with any questions
TCL SUPPORT: support.tcl.com/us
1-800-825-6747
BE CAREFUL WHEN REMOVING THE AIR CONDITIONING UNIT
When compared with other refrigerants, R32 is more environmentally friendly. Please use this product as instructed. This refrigerant is flammable and may combust under certain conditions, however when this product is used as directed these risks are significantly reduced. Always consult with a trained professional when maintaining or repairing an air conditioner.
Warning
Important Considerations
The maximum charge and the required minimum floor area
m1 = (4 m3) x LFL , m2 = (26 m3)) x LFL, m3 = (130 m3 )x LFL
Where LFL is the lower flammable limit in kg/ m3,R290 LFL is 0.038 kg/ m3,R32 LFL is 0.038 kg/ m3.
For the appliances with a charge amount m1 < M = m2:
The maximum charge in a room shall be in accordance with the following: mmax= 2.5 x (LFL)(5/4) x h0 x (A)1/2
The required minimum floor area Amin to install an appliance with refrigerant charge M (kg) shall be in accordance with following: Amin = (M/ (2.5 x (LFL)(5/4) x h0)) 2
Where:
mmax is the allowable maximum charge in a room, in kg;
M is the refrigerant charge amount in appliance, in kg;
Amin is the required minimum room area, in m2;
A is the room area, in m2;
LFL is the lower flammable limit, in kg/m3;
h0 is the installation height of the appliance,in meters for calculating mmax or Amin, 1.8 m for wall mounted;
Table GG.1 – Maximum charge (kg)
Category | LFL (kg/m3) | h 0 (m) | Floor area (m2) | ||||||
4 | 7 | 10 | 15 | 20 | 30 | 50 | |||
R32 | 0,306 | 0,6 | 0,68 | 0,9 | 1,08 | 0,32 | 1,53 | 1,87 | 2,41 |
1 | 1,14 | 1,51 | 1,8 | 2,2 | 2,54 | 3,12 | 4,02 | ||
1,8 | 2,05 | 2,71 | 3,24 | 3,97 | 4,58 | 5,61 | 7,254 | ||
2,2 | 2,5 | 3,31 | 3,96 | 4,85 | 5,6 | 6,86 | 8,85 |
Table GG.2 – Minimum room area (m2)
Category | LFL (kg/m )3 | h 0 (m) | Charge amount (M) (kg) Minimum room area (m2) | ||||||
1,224 kg | 1,836 kg | 2,448 kg | 3,672 kg | 4,896 kg | 6,12 kg | 7,956 kg | |||
R32 | 0,306 | 0,6 | 29 | 51 | 116 | 206 | 321 | 543 | |
1 | 10 | 19 | 42 | 74 | 116 | 196 | |||
1,8 | 3 | 6 | 13 | 23 | 36 | 60 | |||
2,2 | 2 | 4 | 0 | 15 | 24 | 40 |
Installation Safety Principles
Please note that:
Open the carton and remove the below parts.
NO. | APPEARANCE | PART NAME | QUANTITY |
1 | Top Rail | 1 | |
2 | AC Unit | 1 | |
3 | Filler Panels (labeled “Left” & “Right”) | 2 | |
4 | Remote Control (Digital Display Units Only) | 1 | |
5 | Sash Lock | 1 | |
6 | Battery (AAA) | 2 | |
7 | Lock Frame | 2 | |
8 | 3/8’’ Screws | 4 | |
9 | 1/2’’ Screws | 3 | |
10 | 3/4’’ Screws | 4 | |
11 | Window Sash Seal | 1 | |
12 | Foam Top Window Gasket | 1 | |
13 | Foam Insulation (only for E-star models) | 2 |
Note: Illustrations in this manual are for explanatory purposes only. Product design and aesthetics may vary.
Step 1: Testing
Before installing your AC, let’s test it to make sure it works properly and your outlet has the proper power level. First, place it on a flat surface, plug it directly into a wall outlet (never use a power strip or other device), and turn it on. Next, use the Mode button on your control panel to change the AC to Cool Mode and press the down arrow to set the temperature to the lowest setting. After 3 minutes, the AC should be blowing cool air. If so, please continue to the next step. If not, see detailed troubleshooting tips at support.tcl.com/us.
Step 2: Installation
A few quick notes before installing:
How to Control Your AC
All the basics you need to know to stay cool!
5-6K BTU AC
Remove the filter by sliding it out of the front right side of the air conditioner. Gently wash it with a mild dish washing detergent and let dry completely before reinstalling it into the AC.
Remove the filter by removing the air intake grille using the two notches on the top left and right side of the grille cover. Once the grille is removed, you can then remove the filter. Gently wash it with a mild dish washing detergent and let dry completely before reinstalling it into the AC.
Normal Operating Sounds
You may hear a pinging noise, caused by the water hitting the condenser on rainy days, or when the humidity is high.
This design feature helps remove moisture and increase efficiency.
You may hear the thermostat click when the compressor cycles on and off. Water will collect in the base pan on rainy days, or high humidity days. The water may overflow and drip from the unit on the outside. The fan may run, even when the compressor is not on.
Having trouble completing installation? Don’t worry, it’s usually an easy fix.
PROBLEM | POSSIBLE CAUSES | SOLUTIONS |
Air Conditioner will not start | The air conditioner is unplugged | Make sure the air conditioner is plug is pushed completely into the outlet |
The fuse is blown/circuit breaker is tripped |
| |
Power Failure |
| |
The current interrupter device is tripped |
| |
Air Conditioner does not cool as it should | Airflow is restricted | Make sure there are no curtains, blinds, or furniture blocking the front of the air conditioner |
The temperature control may not be set correctly | Lower the set thermostat temperature | |
The air filter is dirty | Clean the filter. See the Cleaning and Care Section of the manual | |
The room may be too warm | Please allow time for the room to cool down after turning on the air conditioner | |
Cold air is escaping | Check for open furnace registers and cold air returns | |
The Cooling Coils are frozen | See “Air Conditioner Freezing Up” below | |
Air Conditioner is freezing up | Ice blocks the air flow and stops the air conditioner from cooling the room |
|
Remote Control is not working | The batteries are inserted incorrectly | Check the position of the batteries |
The batteries may be dead | Replace the batteries | |
Water is dripping outside | Hot and humid weather | This is normal |
Water is dripping inside the room | The air conditioner is not correctly tilted outside | For proper water drainage, make sure the air conditioner is slightly tilted downward from the front of the unit to the rear |
Water collects in the base pan | Moisture removed from the air is draining into the base pan | This is normal for a short period in areas with low humidity and normal for a longer period in areas with high humidity |
Digital Display reads “E1”, “E2” | A sensor has failed | Contact customer service |
What your warranty covers: Defects in materials or workmanship to the original owner of this TCL product when purchased as new from an Authorized Dealer of TCL brand products and packaged with this warranty statement.
WARRANTY PERIOD (NON-COMMERCIAL USE):
WARRANTY PERIOD (COMMERCIAL USE):
Commercial Use includes, but is not limited to, the use of this product in a commercial or business environment, the use of this product in an institution or for institutional purposes, or for other commercial purposes including rental purposes.
Should your TCL device prove to be defective in material or workmanship under normal use during the warranty period listed above, effective from the date of original consumer purchase of the product, TCL North America at its sole discretion will, (1) pay an Authorized TCL Service Center for both labor charges and parts to repair your device, or (2) replace your device with a new or refurbished/recertified equivalent product. If repaired at an Authorized TCL Service Center, TCL is not responsible for the transportation costs to the Authorized TCL Service Center. However, TCL will pay for the return shipping. TCL will provide instructions for the packaging and shipping of the unit. Units that are improperly packed and damaged during shipping are not covered under this limited product warranty. This limited product warranty is good only to the original purchaser of the product and effective only when used in North America. You must have your original purchase receipt or proof of purchase (bill of sale or receipted invoice) which states the condition of the unit (new, used), the unit’s date of purchase, place of purchase, and model/serial number.
HOW SERVICE IS HANDLED: Call 1-800-825-6747 and choose the appropriate prompt. Please have product type, model number, serial number, and ZIP code ready. Troubleshooting and prior approval from a TCL representative MUST occur before sending in your product for repair.
You can find the model number and serial number on a label on the back or side of the product. Register your product online at register.tcl.com.
NO OTHER WARRANTY IS APPLICABLE TO THIS PRODUCT. THIS LIMITED WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW, IT IS LIMITED IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE. NEITHER THE MANUFACTURER NOR ITS DISTRIBUTOR SHALL BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR PROFITS, OR ANY OTHER DAMAGE WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. SOME STATES AND/OR TERRITORIES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE LENGTH OF TIME AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSION OR LIMITATION MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU, THE ORIGINAL PURCHASER, SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE OR TERRITORY TO TERRITORY. THIS WARRANTY IS SUBJECT TO CHANGE WITHOUT NOTICE. PLEASE VISIT WWW.TCL.COM/US TO VIEW THE MOST CURRENT VERSION.
The cost of repair or replacement under these excluded circumstances shall be borne by the consumer.
CONTACT INFORMATION:
TCL North America
1860 Compton Ave
Corona, California 92881
1-800-825-6747 www.tcl.com/us
TCL 5K-14K UN Window Air Conditioner [pdf] User Guide 5K-14K UN Window Air Conditioner, 5K-14K, UN Window Air Conditioner, Window Air Conditioner, Air Conditioner, Conditioner |
LD201 Lockdown Wide Ladder Stand Product Information Product Name: LOCKDOWN WIDE Ladder Stand Model: LD201…
TM 6046 C Grill and Toaster Grill and Toaster User Manual Grill and Toaster User…
Obulb Pro Multicolor Rechargeable LED Light Product Information The Olight Obulb Pro is a portable…
ILVAD Textile and Rug Cleaner ILVAD 105.403.57 Textile and Rug Cleaner ILVAD 105.403.57 Textile and…
PowerStore Expansion Enclosure Product Information The PowerStore Bulletin is a technical newsletter produced by the…