Instruction Manual for Interlogix models including: MN01, MN02, MiNi, MQ03, MQ Series Cellular Communicators and Programming the Panel, Cellular Communicators and Programming the Panel, Communicators and Programming the Panel, Programming the Panel
Panel Programming Resources | Configure Alarm Panels SIMON XTNX-6V2
Panel Programming Resources | Configure Alarm Panels
Interlogix NX-8 Wiring M2M's MN/MQ Series Cellular Communicators and Programming the Panel Doc. Nr. 06046, ver.2, Feb-2025 CAUTION: It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality. Do not route any wiring over circuit board. Full panel testing, and signal confirmation, must be completed by the installer. NEW FEATURE: For MN/MQ Series Communicators, the status of the panel can be retrieved not only from the status PGM but now also from the Open/Close reports from the dialer. Therefore, wiring the white wire and programming of the status PGM of the panel is optional. Wiring the white wire is necessary only if the Open/Close reporting is disabled. IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the initial pairing procedure. M2M_Interlogix_NX-8_Wiring_Programming_Feb-2025 1 of 5 © M2MServices 2025 Interlogix NX-8 Wiring M2M's MN/MQ Series Cellular Communicators and Programming the Panel Doc. Nr. 06046, ver.2, Feb-2025 Wiring the MN01 and MiNi communicator series for events reporting and remote control via keybus* *Remote control via the keybus allows you to arm/disarm or arm in stay multiple partitions, bypass zones and get the status of the zones. Wiring the MN01, MN02 and MiNi communicator series for events reporting and remote control via Keyswitch* *The optional keyswitch configuration can be used for M2M communicators that do not support keybus functionality. You do not need to configure this option if your device supports remote control via the keybus. M2M_Interlogix_NX-8_Wiring_Programming_Feb-2025 2 of 5 © M2MServices 2025 Interlogix NX-8 Wiring M2M's MN/MQ Series Cellular Communicators and Programming the Panel Doc. Nr. 06046, ver.2, Feb-2025 Wiring the MQ03 communicator series for events reporting and remote control via Keyswitch* *The optional keyswitch configuration can be used for M2M communicators that do not support keybus functionality. You do not need to configure this option if your device supports remote control via the keybus. Wiring the MN01, MN02 and MiNi Series with Ringer MN01-RNGR to Interlogix NX-8 for UDL M2M_Interlogix_NX-8_Wiring_Programming_Feb-2025 3 of 5 © M2MServices 2025 Interlogix NX-8 Wiring M2M's MN/MQ Series Cellular Communicators and Programming the Panel Doc. Nr. 06046, ver.2, Feb-2025 Wiring the MQ03 Series to Interlogix NX-8 for UDL Programming the Interlogix NX-8 Alarm Panel via the Keypad Enable Contact ID reporting: LED LEDSs of Ready, Power Steady ON Service LED blinks Service LED blinks, Armed LED steady ON Keypad Entry *8 9713 0# 0# Service LED blinks, Ready LED steady ON 15*1*2*3*4*5*6*# Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON All Zone LEDs are ON All Zone LEDs are ON All Zone LEDs are ON Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON Ready Led steady ON Service LED blinks, Armed LED steady ON 1# 1*2*3*4*# 2# 13* 4# * * 23# ** 1* Exit, Exit Action Description To enter programming mode To go to main panel programming menu To enter phone number menu 15* (to choose phone dialing), followed by your desired phone number (123456 is just an example) each figure is followed by *, # to save and go back To go to account number menu Enter the desired account number (1234 is an example), # to save and go back To go to communication format To choose Contact ID, * to save To go to events reported to phone 1 To confirm all events reporting and go to next section To confirm all events reporting and go back To go to feature report section To go to section 3 of the toggle options menu To enable Open/Close reporting Press "Exit" two times to exit programming mode M2M_Interlogix_NX-8_Wiring_Programming_Feb-2025 4 of 5 © M2MServices 2025 Program Keyswitch zone and output: LED LEDSs of Ready, Power Steady ON Service LED blinks Service LED blinks Service LED blinks, Ready LED steady ON Service LED blinks, Armed LED steady ON Service LED blinks, Ready LED steady ON Service LED blinks, Ready LED steady ON Service LED blinks, Armed LED steady ON Keypad Entry *8 9713 0# 25# 11*# 47# 21* 0* Exit, Exit Interlogix NX-8 Wiring M2M's MN/MQ Series Cellular Communicators and Programming the Panel Doc. Nr. 06046, ver.2, Feb-2025 Action Description To enter programming mode To go to main panel programming menu To go to zone type menu To set Zone 1 as a Momentary Keyswitch, *# to save and go back To go to AUX 1 Output events and time menu To choose armed state event as an event that will activate the AUX 1 To disable the output timer (the hold status) Press "Exit" two times to exit programming mode Programming the GE Interlogix NX-8 Alarm Panel via the Keypad for remote Upload/Download (UDL) Program the Panel for Upload/Download (UDL): Display System ready Enter device address Enter location Loc#19 Seg# Enter location Loc#20 Seg# Enter location Loc#21 Seg# Enter location Keypad Entry *89713 00# 19# 8, 4, 8, 0, 0, 0, 0, 0, # 20# 1# 21# 1, 2, 3, 8, # Exit, Exit Action Description Enter programming mode. To go to main edit menu. Start configuring "Download Access Code". By default, it is "84800000". Set the Download Access Code to its default value. Press # to save and go back. IMORTANT! This code should match the one set in the "DL900" software. To go to "Number of rings to answer" menu. Set number of rings to answer to 1. Press # to save and go back. Go to "Download control" toggle menu. All of these (1,2,3,8) should be OFF in order to disable "AMD" and "Call back". Press "Exit" twice to exit programming mode. M2M_Interlogix_NX-8_Wiring_Programming_Feb-2025 5 of 5 © M2MServices 2025Acrobat Distiller 24.0 (Windows)