Digilock Installation Guide
Keypad & RFID
Shared & Assigned Use
Standard, Vertical, & Horizontal Body
Before Lock Installation
The door must be prepared for lock installation.
1. Strike Plate
A strike plate must be installed.
Types of Strike Plates:
- Angled Strike Plate
- Security Strike Plate
- Double Door Strike Plate
2a. Door Mounting Holes (Surface Mount)
For surface mount installations, the door must have door mounting holes.
- For Standard & Vertical Body
- For Horizontal Body
2b. Routed Door with Door Mounting Holes (Recess Mount)
For recess mount installations, the door must be routed and have door mounting holes.
- For Standard Body
- For Vertical Body
- For Horizontal Body
Surface Mount Installation
For door thickness measuring between .01” - .480” (0.01mm - 12.0mm)
Required Components
1 - Front Unit
- Standard Body Keypad
- Standard Body RFID
- Vertical Body Keypad
- Vertical Body RFID
- Horizontal Body Keypad
1 - Rear Unit
- Springbolt
- Springlatch
- Deadbolt
- Deadlatch
1 - Plastic Ring
1* - Pin Extender
*Required for door thickness measuring between .315"-.480" (8.0-12.2mm)
1* - Ratchet/Screw Gun with a 3/8" Socket
*Not included
Note: Do not use an electric screw gun unless it is equipped with a torque adjuster and is set to low.
Installation
For illustration, a standard body, keypad lock with a bolt rear unit is used.
- Place the plastic ring on the front unit.
- If required, connect the pin extender to the rear unit.
- Insert the front unit screw posts through the door mounting holes.
- Hold the front unit against the front of the door. Use the rear unit mounting holes as a guide, then slide the front and rear units together.
- Make sure the connector pins align properly with the connector. If properly connected, a triple beep will be heard and the LED will flash three times.
- Insert the locking nuts on the screw posts and tighten using the ratchet/screw gun. Do not over tighten.
- To test keypad locks: Press [Enter] [Code].
- To test RFID locks: Press [Enter] [RFID Card].
Test the locks while the door is open. If locks do not operate, remove and reinstall.
Close the door and test again. If 10 rapid beeps are heard and the LED flashes 10 times, the strike plate and/or the door needs to be adjusted as it is preventing the lock from operating.
Surface Mount Installation
For door thickness measuring between .480" - 1.998" (12.2mm - 50.7mm)
Required Components
1 - Front Unit
- Standard Body Keypad
- Standard Body RFID
- Vertical Body Keypad
- Vertical Body RFID
- Horizontal Body Keypad
1 - Rear Unit
- Springbolt
- Springlatch
- Deadbolt
- Deadlatch
1 - Plastic Ring
2 - Phillips Head Screws
2 - Split Lock Washers
1* - Phillips Head Screwdriver (#2)
1* - Pin Extender
*Two (2) pin extenders are required for door thickness measuring between 1.20"-1.998" (30.5-50.7mm)
*Not included
Note: Do not use an electric screw gun unless it is equipped with a torque adjuster and is set to low.
Installation
For illustration, a standard body, keypad lock with a bolt rear unit is used.
- Place the plastic ring on the front unit.
- Connect the pin extender to the rear unit.
- Place the split lock washers on the phillips head screws and insert them through the rear unit mounting holes.
- Insert the front unit nut posts through the door mounting holes.
- Hold the front unit against the front of the door. Use the screws of the rear unit as a guide then slide the front and rear units together.
- Make sure the connector pins align properly with the connector. If properly connected, a triple beep will be heard and the LED will flash three times.
- Tighten the screws using the phillips head screw driver. Do not over tighten.
- To test keypad locks: Press [Enter] [Code].
- To test RFID locks: Press [Enter] [RFID Card].
Test the locks while the door is open. If locks do not operate, remove and reinstall.
Close the door and test again. If 10 rapid beeps are heard and the LED flashes 10 times, the strike plate and/or the door needs to be adjusted as it is preventing the lock from operating.
Recess Mount Installation
For door thickness measuring between .370" - .850" (9.4mm - 21.6mm)
Required Components
1 - Front Unit
- Standard Body Keypad
- Standard Body RFID
- Vertical Body Keypad
- Vertical Body RFID
- Horizontal Body Keypad
1 - Rear Unit
- Solenoid Spring Bolt
- Solenoid Spring Latch
- Motorized Dead Bolt
- Motorized Dead Latch
1* - Pin Extender
*Required for door thickness measuring between .685"-.850" (17.4-21.6mm)
1* - Ratchet/Screw Gun with a 3/8" Socket
2 - Locking Nuts
*Not included
Note: Do not use an electric screw gun unless it is equipped with a torque adjuster and is set to low.
Installation
For illustration, a standard body, keypad lock with a bolt rear unit is used.
- If required, connect the pin extender to the rear unit.
- Insert the front unit screw posts through the door mounting holes.
- Hold the front unit against the front of the door. Use the screws of the rear unit as a guide then slide the front and rear units together.
- Make sure the connector pins align properly with the connector. If properly connected, a triple beep will be heard and the LED will flash three times.
- Insert the locking nuts on the screw posts and tighten using the ratchet/screw gun. Do not over tighten.
- To test keypad locks: Press [Enter] [Code].
- To test RFID locks: Press [Enter] [RFID Card].
Test the locks while the door is open. If locks do not operate, remove and reinstall.
Close the door and test again. If 10 rapid beeps are heard and the LED flashes 10 times, the strike plate and/or the door needs to be adjusted as it is preventing the lock from operating.
Recess Mount Installation
For door thickness measuring between .850" - 2.368" (21.6mm - 60.1mm)
Required Components
1 - Front Unit
- Standard Body Keypad
- Standard Body RFID
- Vertical Body Keypad
- Vertical Body RFID
- Horizontal Body Keypad
1 - Rear Unit
- Solenoid Spring Bolt
- Solenoid Spring Latch
- Motorized Dead Bolt
- Motorized Dead Latch
1* - Phillips Head Screwdriver (#2)
1* - Pin Extender
*Two (2) pin extenders are required for door thickness measuring between 1.570"-2.368" (39.9-60.1mm)
2 - Phillips Head Screws
2 - Split Lock Washers
*Not included
Note: Do not use an electric screw gun unless it is equipped with a torque adjuster and is set to low.
Installation
For illustration, a standard body, keypad lock with a bolt rear unit is used.
- Connect the pin extender to the rear unit.
- Place the split lock washers on the phillips head screws and insert them through the rear unit mounting holes.
- Insert the front unit nut posts through the door mounting holes.
- Hold the front unit against the front of the door. Use the screws of the rear unit as a guide then slide the front and rear units together.
- Make sure the connector pins align properly with the connector. If properly connected, a triple beep will be heard and the LED will flash three times.
- Tighten the screws using the phillips head screw driver. Do not over tighten.
- To test keypad locks: Press [Enter] [Code].
- To test RFID locks: Press [Enter] [RFID Card].
Test the locks while the door is open. If locks do not operate, remove and reinstall.
Close the door and test again. If 10 rapid beeps are heard and the LED flashes 10 times, the strike plate and/or the door needs to be adjusted as it is preventing the lock from operating.
Door Preparation
Strike Plate Installation
Required Components
- Strike Plate
1. A strike plate must be installed.
Types of Strike Plates:
- Angled Strike Plate
- Security Strike Plate
- Double Door Strike Plate
1* - Phillips Head Screwdriver (#1)
*Not included
Note: Do not use an electric screw gun unless it is equipped with a torque adjuster and is set to low.
Installation
- Position the strike plate on the door frame centering it with the center of the desired location of the door mounting holes.
- Allow .125" (3.18mm) from door edge and mark the position of the adjustment slot holes.
- Drill 0.25" (6.35mm) pilot holes using a 1/8" drill bit.
- Position the strike plate and the self tapping screws into the adjustment slot holes. Do not tighten the screws.
- Adjust the strike plate to the proper position (.125" (3.18mm) from the door edge) then tighten the self tapping screws.
- Position and tighten the remaining self tapping screw into the center hole.
Door Mounting Holes Drill Instructions and Templates
Drill Instructions
For illustration, the mounting holes template for standard & vertical body locks is used.
- Align both the center line and strike plate edge of the installed strike plate. Hold the template in place and close the door.
- Mark the edge of the door on the template. Mark the center line of the template on the edge of the door.
- Place the template on the front of the door. Align the edge of the door with the mark on the template, and then align the center line of the template with the mark on the door. Secure the template with removable tape.
- Mark the center point of the three door mounting drill holes on the front of the door. Use the drill bits specified on the template to drill appropriately sized door mounting holes.
Template for Standard & Vertical Body
Templates may not print to scale. Check all measurements before proceeding. Before printing, turn off auto scaling in printer setup and print at 100%.
Center Line
Align Edge of Strike Plate Here for Left Closing Door
Align Edge of Strike Plate Here for Right Closing Door
Measurements are in thousandths of an inch and millimeters:
- Two holes: .300 (7.62mm) use 5/16" bit
- One hole: .750 (19.05mm) use 3/4" bit
- Various dimensions provided for precise alignment.
Template for Horizontal Body
Templates may not print to scale. Check all measurements before proceeding. Before printing, turn off auto scaling in printer setup and print at 100%.
Center Line
Align Edge of Strike Plate Here for Top Closing Drawer
Align Edge of Strike Plate Here for Bottom Closing Drawer
Measurements are in thousandths of an inch and millimeters:
- Two holes: .300 (8mm)
- One hole: .750 (19mm)
- One hole: .300 (8mm)
- Various dimensions provided for precise alignment.
Routing Template for Standard Body
Templates may not print to scale. Check all measurements before proceeding. Before printing, turn off auto scaling in printer setup and print at 100%.
- Dimensions provided for routing: 2.01 in (51 mm) x 1.98 in (50 mm)
- Hole diameters: .300 in (8mm) (2x), .75 in (19mm)
- Depth: .400/.425 in DEEP (10/11 mm)
- Corner radius: R 0.125" (3mm) (4x)
Routing Template for Horizontal Body
Templates may not print to scale. Check all measurements before proceeding. Before printing, turn off auto scaling in printer setup and print at 100%.
- Dimensions provided for routing: 2.185" (56mm) x 3.80" (97mm) / 3.78" (96mm)
- Hole diameters: .75" (19mm), .30" (8mm) (2x)
- Depth: .400/.425 DEEP (10/11mm)
- Corner radius: R 0.125" (3mm) (4x)
- Dimensions for strike plate alignment: 1.100 (27.9mm), .905 (23mm)
Routing Template for Vertical Body
Templates may not print to scale. Check all measurements before proceeding. Before printing, turn off auto scaling in printer setup and print at 100%.
- Dimensions provided for routing: 2.185" (56mm) x 3.80" (97mm) / 3.78" (96mm)
- Hole diameters: 1.25" (32mm) / 1.23" (31mm), .30" (8mm) (2x), .75" (19mm)
- Depth: .400/.425 DEEP (10/11mm)
- Corner radius: R 0.125" (3mm) (4x)
Metal Door Preparation
Compatibility Guide
Digilock is compatible with a majority of 3-hole configuration, latch, and handle door types. Some doors may require modification to clear obstructions.
- Single Point Latch
- Standard Lift
- Recessed Cup with Multi-point Latch
- Handle
- Box Locker Padlock Hasp
- Recessed Cup with Single Point Latch
Removal of 3-hole Lock Plug
Remove any obstructions to the door mounting holes.
Example 1:
- Rear View of Locker Door with Lock Plug
- Front View of Locker Door with Lock Plug
Example 2:
- Rear View of Locker Door with Lock Plug
- Front View of Locker Door with Lock Plug
Removal of Padlock Hasp
The padlock hasp must be removed.
Tools:
- 1 - Handheld Grinder or Hack Saw
- 1 - Metal File
Procedure:
- Close the door and make sure that nothing is protruding above the surface of the door.
- Open the door then cut the padlock hasp on the marked cut-line.
- Smooth out rough or sharp edges.
- Close the door and mark the area to cut the padlock hasp.
Example 1: [Diagram showing removal process]
Example 2: [Diagram showing removal process]