Spiderdoor S33 Access Control Keypad Installation Guide

S33 Access Control Keypad

Product Specifications:

  • Input Power Range: 12V – 24V
  • Power Adapter: Provided
  • Network Connectivity: CAT 5/6
  • LED Indicator: Blue Light

Product Usage Instructions:

Option 1 – Using Power Adapter Provided:

1. Connect the power adapter into the green input labeled GND/V+
on the keypad.

2. Ensure the power supplied to the adapter is within the range
of 12V – 24V.

3. Do not attempt to power the keypad using the power board from
a gate motor; always use the provided adapter to prevent
damage.

Owner/Manager Steps:

1. Download the Spiderentry Managers App from your mobile
device’s app store.

2. Use the login credentials provided by Spiderdoor team members
to access the app.

3. Visit www.management.spiderdoor.com on your desktop to manage
gate activities.

Installation Steps:

1. Unpack the box and ensure all items are present as shown in
the manual.

2. Unlock and open the front door for installation, being
cautious not to damage it during the process.

3. Mount the keypad on a wall/stud securely using sheetrock
screws.

Mag Lock Installation:

If using a Magnetic lock, connect the green wire to N/C
(normally closed) and the blue wire to COM (common wire) from the
keypad to the lock installed on the door.

Gate Installation:

Connect wires from normally open (NO) and common (COM) on the
gate motor to the input labeled gate on the keypad board.

Option 2 – Using POE For Power:

1. Plug a CAT5/6 cable from your modem into the slot labeled CAT
5/6 on the keypad.

2. Connect another CAT5/6 cable from the slot labeled OUT on the
POE SWITCH to power the device.

Frequently Asked Questions (FAQ):

Q: What should I do if the keypad is not receiving power?

A: Ensure that the power supplied is within the specified range
of 12V – 24V and use the provided adapter to avoid any damage to
the keypad.

Q: How can I check if a code entered is valid?

A: A solid 4-second buzz indicates that the gate code entered is
correct, while three short beeps signify an invalid or inactive
code.

“`

5b OPTION 1 – Using Power Adapter Provided: The power should connect into the green input labeled GND /V+. This should be ran to the supplied adapter for the proper amount of power. Note that the keypad can only handle between 12v – 24v and nothing below or above. Warranty does not cover a damaged pad due to improper power installation. DO NOT attempt to power the keypad using the power board from a gate motor. You must use the adapter provided.
LED Blue Light

S Spidedoor 205-821-6000
INSTALL GUIDE

33

1 Unpack the box and make sure you have all items shown below.

S3434hKKeeyyppaadd

Relay 1 Relay 2
CAT 5/6

Gate

Maglock NO/CO/NC

GND +12v

Override

Owner/Manager Steps
Download Managers App! You will need login credentials, which will be provided to you by a Spiderdoor team member. Search App stores on your mobile device for the Spiderentry Managers App. Download the app and this will allow managers to access their gates from anywhere. Lastly, You can also login on your desktop at
www.management.spiderdoor.com This will allow you to view activity log, photos of tenants, (on certain keypad models) and open or latch open your gate, all from the Spiderdoor dashboard. Email us at Support@Spiderdoor.com

Keys Power Adapter (required)
2 Unlock and open the front door to install and wire properly. Door will pull forward but needs to be lifted out of the slots during install. Do not open door too far or you can damage! You can also unplug punch pad cable if needed during install. Be careful when pluggin punch pad cable back in.

PAGE 4

Jun 2025

Open half way, then lift out
WARNING
AUTOMATIC GATE CAN CAUSE SERIOUS INJURY OR DEATH! ALWAYS CHECK THAT THE GATE PATH IS CLEAR PRIOR TO OPENING!
SAFETY REVERSING DEVICES SHOULD ALWAYS BE USED!
PAGE 1

3 Mounting on awall/stud: Choose which side your stud is on and simply punch out the holes on the desired side. Then use a sheetrock screw or a comparable type screw to secure the keypad to the wall. Be sure to secure the pad somewhere at the top of the keypad as well as at the bottom. You can mount to pedestal as well.
LED Blue Light

Relay 1 Relay 2 CAT 5/6

Gate

Maglock

NO/CO/NC

GND +12v

Override

4b Mag Lock Install: If using a Magnetic lock for a walk through door, you will want to use N/C (normally closed) and the COM

(common wire) slot. In the illustration below, the green wire goes

to the magnetic lock from the keypad. The blue wire also goes

from the keypad out to the magmetic lock installed on the walk

through door.

Keypad Sounds

ACTIVE CODE
Asolid4 secondbuzz meansthe gatecodeenteredis agoodcode..

N/C COM

INACTIVE CODE
Three short beeps signifies that a codeis INACTIVEornogood.

4a Gate Install: Bring one wire from normally open(NO) and one wire from common(COM) on the gate motor over to the input labeled gate on the board. Input labeled GATE, represents normally open and common inputs.

N/C COM

LED Blue Light

Gate

Relay 1 Relay 2
CAT 5/6

Gate

Maglock NO/CO/NC

GND +12v

Override

PAGE 2

Dec 2023

Maglock

5a OPTION 2 – Using POE For Power: Plug a CAT5/6 cable from your current modem (coming from current internet provider – Orange

cable) into the slot labeled CAT 5/6 Then plug another CAT 5/6 cable into slot labeled”OUT,”on the POE SWITCH and this line will

go straight to your keypad (Using yellow Cable in diagram). This

cable is what gives your keypad low voltage DC power that is

needed to run the keypad. Plug into the CAT5/6 input inside

keypad.

POWER OVER ETHERNET

SWITCH

IN

From your internet provider

OUT

Out to SpiderENTRY keypad

REQUIRED: Call us at 205-821-6000, 24 hours in advance or email Support@Spiderdoor.com
PAGE 3

FCC Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: The grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. Such modifications could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ­ Reorient or relocate the receiving antenna. ­ Increase the separation between the equipment and receiver. ­ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ­ Consult the dealer or an experienced radio/TV technician for help. RF exposure statement This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 30cm between the radiator and any part of your body. Canadian Compliance Statement This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada license-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device. L’émetteur/récepteur exempt de licencecontenudans le présentappareilestconformeaux CNRd’Innovation, Sciences et Développementéconomique Canada applicables aux appareils radio exempts de licence. L’exploitationestautorisée aux deux conditions suivantes : L’appareil ne doit pas produire de brouillage; L’appareildoitaccepter toutbrouillageradioélectriquesubi, mêmesi le brouillageest susceptible d’encompromettre le fonctionnement.
RF exposure statement
This equipment meets the exemption from the routine evaluation limits in section 6 of RSS102. It should be installed and operated with a minimum distance of 30cm between the radiator and any part of your body. Cetéquipementestconforme à l’exemption des limitesd’évaluationhabituelle de la section 6 de la norme RSS-102. Il doitêtreinstallé et utilisé à une distance minimale de 30 cm entre le radiateur et toutepartie de votre corps.

Supplier’s Declaration of Conformity 47 CFR § 2.1077 Compliance Information
Product Name: Access Control Keypad Product Model: S23, S33 Manufacturer: Spiderdoor 2284 Brock Circle Birmingham, Alabama 35242
support@spiderdoor.com www.spiderdoor.com
Modular Components Used: NAME: nRF91 MODEL: nrRF9160 FCC ID: 2ANPO00NRF9160
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Documents / Resources

Spiderdoor S33 Access Control Keypad [pdf] Installation Guide
S44h, S33 Access Control Keypad, S33, Access Control Keypad, Control Keypad, Keypad

References