Energy Meter with Modbus Connection for SolarEdge Installations

  • High-accuracy meter readings for production/consumption monitoring
  • Import/Export meter readings for export limitation functionality
  • Small and easy to install – fits in standard electrical panels
  • Supports residential, commercial, and utility-size installations
  • Supports RS485 120Ω line termination

Energy Meter with Modbus Connection

SE-MTR-3Y-400V-A

WHEN ORDERING A METER, ORDER CURRENT TRANSFORMERS AS WELL:

solaredge A-400V-3Y-MTR-SE Energy Meter with Modbus Connection 1

CURRENT

TRANSFORMER MODEL(1)

RATED RMS

CURRENT(A)

INTERNAL (A X B) /

EXTERNAL (C X D)

SE-CTML-0350-0707010 x 10 mm / 25.4 x 39 mm
SECT-SPL-100A-A10016 x 16 mm / 44 x 31 mm
SECT-SPL-250A-A25024 x 25 mm / 46.2 x 65.4 mm
SECT-SPL-1000A-A100052 x 52 mm / 120 x 125 mm
SE-CTB-4×4-12001200102 x 102 mm / 158 x 168 mm
SE-CTB-4×4-20002000102 x 102 mm / 158 x 168 mm
SE-CTB-4×4.5-30003000114 x 102 mm / 171 x 168 mm

Current Transformer Dimensions

solaredge A-400V-3Y-MTR-SE Energy Meter with Modbus Connection 2

SE-MTR-3Y-400V-A                                          UNITS
ELECTRICAL SERVICE
Operating Voltage RangeLine to Line207 – 440Vac
Line to Neutral108 – 305Vac
Nominal Voltage RangeLine to Line230 – 400Vac
Line to Neutral120 to 277Vac
AC Frequency45 – 65Hz
Grids Supported(2) – Single Phase ; Three PhaseL / N / PE ; L1 / L 2 / L3 / N / PE 
Power Consumption (max)3W
CT Inputs333mV
COMMUNICATION
Supported Communication InterfacesRS485 half-duplex, 3 wires (A, B, GND) 
Response Time(3)≤200ms
Default Device ID (Modbus)2 
RS485 Line Termination120Ω
ACCURACY (@25°C, PF: 1)(4)
1% – 100% of Rated CT Current±1.25%
IEC AccuracyIEC 62053-21 Class 1, IEC 62053-23 Class 2 
STANDARD COMPLIANCE
SafetyIEC 61010-1, UL 61010-1, CAN/CSA-C22.2 No. 61010-1-04 
ImmunityEN 61326: 2000, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-5, EN 61000-4-6, 
EmissionsEN 55022 Class B 
INSTALLATION SPECIFICATIONS
Dimensions (HxWxD)75 x 138.6 x 35 / 2.95 x 5.45 x 1.37mm / in
Weight225 / 0.49gr / lb
Operating Temperature Range-40 to +85 / -40 to +185°C / °F
Relative Humidity (non-condensing)5% to 90% up to 40°C decreasing linearity to 50% RH at 55°C 
Protection RatingIP20 – Suitable for indoor use 
Mounting TypeDIN Rail / Surface mount 
AC voltage Terminal Blockup to 12 / 2.5AWG/mm2
Communication Terminal Block24 / 0.2 to 14 / 2AWG/mm2
Current Transformer Terminal Block24 / 0.2 to 14 / 2AWG/mm2

 

  • PE (Protective Earth) connection is not required for meter operation
  •  For power limitation application. When meter is connected at grid connection point, and when RS485 is used for multiple inverters
  • ±1.75% from 10% to 100% of rated current for SE-CTB CTs

© SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 07/2021 DS-00002-1.0-ENG. Subject to change without notice.

Documents / Resources

solaredge A-400V-3Y-MTR-SE Energy Meter with Modbus Connection [pdf] Instructions
A-400V-3Y-MTR-SE Energy Meter with Modbus Connection, A-400V-3Y-MTR-SE, Energy Meter with Modbus Connection, Energy Meter, Meter

References

Leave a comment

Your email address will not be published. Required fields are marked *