ZiPWAKE Series E Dynamic Trim Control System Installation Guide
TOOLS
- Drill bits
Ø 2.5 mm (3/32″)
Ø 3 mm (1/8″)
Ø 4 mm (5/32″)
Ø 5 mm (3/16″)
Ø 6.5 mm (1/4″) - Hole saw
Ø 19 mm (3/4″) - Screw bits
T10
T20
T25
T30
T40 - Power drill
- Sealant
- Flat screwdriver
- Bits screwdriver
- Wrench
13 mm (33/64″)
27 mm (1 1/16″) - Utility knife
- Hacksaw
- Antifouling
KIT BOX CONTENTS
- Operator’s Manual
- Warranty Card
- Installation Guide
- Drill Templates
- Mounting Screws
- Operator’s Quick Guide
- Startup Checklist
SYSTEM OVERVIEW
MOUNTING OPTIONS
THRU-HULL CABLE FITTINGS
Depending on preference, the interceptors can be mounted with thru-hull cable fittings above the waterline (A) or below, concealed behind the interceptors (B).
ALLOWED SPRAY RAIL OVERLAP
PROPELLER CLEARANCE
If the boat has an outboard engine or sterndrive, the interceptors must be mounted with clearance to the propeller(s).
CONVEX BOTTOM CURVATURE
CONCAVE BOTTOM CURVATURE
PREPARE THE TRANSOM
ENSURE A FLAT SURFACE FOR EACH INTERCEPTOR
NOTE! Only if a concealed thru-hull fitting will be used
Option 1:
- Pilot hole Ø 3 mm (1/8″)
- Hole saw Ø 19 mm (3/4″)
Option 2 (threaded hole):
- Pilot hole Ø 3 mm (1/8″)
- Hole saw Ø 16 mm (5/8″)
- Tap M18 x 2.5
INSTALL THE BACK PLATES
A. FOR THRU-HULL FITTINGS ABOVE THE WATERLINE GO STRAIGHT TO STEP B
B. MOUNT THE BACK PLATE
INSTALL THRU-HULL FITTINGS ABOVE THE WATERLINE







INSTALL CONCEALED THRU-HULL FITTINGS UNDER THE WATERLINE
INSTALL THE INTERCEPTOR FRONTS
PAINT THE INTERCEPTORS WITH ANTIFOULING
MOUNT THE DISTRIBUTION UNIT
Mount the distribution unit inboard where it is easy to connect it to both interceptors and power supply (battery) e.g. the engine room or other suitable compartment.
NOTE!
The maximum cable length (including extra cable) from an interceptor to the distribution unit is 6 m (20 ft).
CONNECT THE DISTRIBUTION UNIT
NOTE! Detailed wiring diagram is available at the end of this folder.
MOUNT THE INTEGRATOR MODULE
MOUNT THE INTEGRATOR MODULE
Mount the integrator module on a rigid surface where it is easy to connect it to the distribution unit and other equipment e.g. under the dash or another suitable compartment. If the system will be used with mobile devices, mount the integrator module for maximum signal strength.
NOTE!
0.5 m (1.6 ft) safe distance to magnetic compass.
Mounting restrictions
Mount the integrator module within the angles shown in figures 1-3.
NOTE!
Make sure the integrator module orientation angle (mounting angle relative the boat’s forward direction) is set as accurately as possible (±5°) during initial start-up.
CONNECT THE INTEGRATOR MODULE
Route the cables between the integrator module, the distribution unit and optional multifunction display (MFD) and/or other equipment. Use optional extension cables if necessary.
External GPS (optional*)
With the integrator module connected, the system can be controlled from one or several sources e.g. an MFD, a mobile device or a Zipwake control panel.
NOTE! Detailed wiring diagram is available at the end of this folder.
IMPORTANT The integrator module requires at least one external GPS signal via MFD, NMEA 2000, Zipwake control panel or Zipwake external GPS.
INITIAL START
Refer to the Operator’s Manual for detailed information about setting up and operating the system.
SETTING UP THE SYSTEM
MULTIFUNCTION DISPLAY (MFD)
The Zipwake application automatically appears on a connected (compatible) MFD. Refer to the MFD manufacturer or manual for detailed information on compatible models and how to launch integration applications such as the Zipwake Integrator Module interface on your MFD model. At first start-up, follow the steps on the MFD to complete system installation.
MOBILE DEVICE
Scan the QR-code from integrator module label 1 to connect to the Wi-Fi network. Scan the QR-code from integrator module label 2 to install the Zipwake App and add it to the device start screen for future use. Follow the steps in the app to complete system installation.
NOTE!
Make sure the integrator module orientation angle (mounting angle relative to the boat’s forward direction) is set as accurately as possible.
INTERCEPTOR CHECK
Carry out an Interceptor Check to verify function immediately after installation and before launching the boat. Repeat this before every launch.
NOTE! Interceptor Check will not start if no interceptor configuration has been saved to the system (refer to the Operator’s Manual).
The check repeats a 5 stroke sequence, where each interceptor blade is extended, one by one, from port to starboard and then retracted in the same order. Visually confirm that the interceptors move accordingly during the check. This confirms that the interceptors are correctly connected to the distribution unit(s).
All readings must be green!
Corrective action is always necessary when excessive servo torque levels are
observed. The root cause is usually the flatness of the transom behind the interceptor and/or excess antifouling between its blades.
IMPORTANT
Always use the controls to move the interceptor blades. Never try to force the interceptor blades by hand.
ACCESSORIES
Model | Part No. | Description |
CP-E | 2012032 | CONTROL PANEL E WITH STANDARD CABLE 15 M |
DU-EX | 2012034 | DISTRIBUTION EXPANSION UNIT E WITH POWER CABLE 6 M |
IT400-E | 2012215 | INTERCEPTOR 400 E WITH CABLE 3 M & CABLE COVER |
IT600-E | 2012018 | INTERCEPTOR 600 E WITH CABLE 3 M & CABLE COVER |
IT800-E | 2012019 | INTERCEPTOR 800 E WITH CABLE 3 M & CABLE COVER |
IT1000-E | 2012020 | INTERCEPTOR 1000 E WITH CABLE 3 M & CABLE COVER |
IT600-E TUNNEL R500 | 2012021 | NTERCEPTOR 600 E TUNNEL R500 WITH CABLE 3 M & CABLE COVER |
IT600-E TUNNEL R600 | 2012022 | INTERCEPTOR 600 E TUNNEL R600 WITH CABLE 3 M & CABLE COVER |
IT600-E TUNNEL R800 | 2012023 | NTERCEPTOR 600 E TUNNEL R800 WITH CABLE 3 M & CABLE COVER |
IT400-E CHINE PORT | 2012216 | INTERCEPTOR 400 E CHINE PORT SIDE WITH CABLE 3 M & CABLE COVER |
IT400-E CHINE STBD | 2012217 | INTERCEPTOR 400 E CHINE STARBOARD SIDE WITH CABLE 3 M & CABLE COVER |
IT600-E CHINE PORT | 2012024 | INTERCEPTOR 600 E CHINE PORT SIDE WITH CABLE 3 M & CABLE COVER |
IT600-E CHINE STBD | 2012025 | INTERCEPTOR 600 E CHINE STARBOARD SIDE WITH CABLE 3 M & CABLE COVER |
EC1.5-M12 | 2011258 | 8 M12 EXTENSION CABLE 1.5 M |
EC3-M12 | 2011259 | M12 EXTENSION CABLE 3 M |
EC5-M12 | 2011260 | M12 EXTENSION CABLE 5 M |
EC10-M12 | 2011261 | M12 EXTENSION CABLE 10 M |
EC15-M12 | 2012038 | M12 EXTENSION CABLE 15 M |
EC20-M12 | 2012039 | M12 EXTENSION CABLE 20 M |
CC-EX | 2012036 | CABLE COVER EXTENSION E KIT |
GPU | 2011240 | GLOBAL POSITIONING UNIT WITH CABLE 5 M & MOUNT KIT |
WIRING DIAGRAM
DU/INTERCEPTOR CONFIGURATIONS
NOTE!
Transom inside view
Visit zipwake.com for additional information such as:
- Operator’s Manual and Installation Guide in different languages
- Product specifications, including a list of accessories and spare parts
- Application examples and interceptor mounting options
- Drawings and 3D models of system components
- Software upgrades for your Dynamic Trim Control System
Documents / Resources
![]() | ZiPWAKE Series E Dynamic Trim Control System [pdf] Installation Guide Series E, Series E Dynamic Trim Control System, Dynamic Trim Control System, Trim Control System, Control System |
![]() | ZiPWAKE Series E Dynamic Trim Control System [pdf] Installation Guide Series E, IT300-S, Dynamic Trim Control System, Series E Dynamic Trim Control System, Trim Control System, Control System |
![]() | ZIPWAKE Series E Dynamic Trim Control System [pdf] Installation Guide Series E, Series E Dynamic Trim Control System, Dynamic Trim Control System, Trim Control System, Control System, System |
![]() | ZIPWAKE SERIES E Dynamic Trim Control System [pdf] Installation Guide SERIES E, 2012111, SERIES E Dynamic Trim Control System, SERIES E, Dynamic Trim Control System, Trim Control System, Control System |
![]() | ZIPWAKE Series E Dynamic Trim Control System [pdf] User Guide Series E 7, 1010157, Series E Dynamic Trim Control System, Series E, Dynamic Trim Control System, Trim Control System, Control System |