1. Features
Fancy shape designed, popular for all decorations
Casing is fi reproof and anti UV design, safety and anti- aging Slid up casing, easy for installation
Standard 6P crystal socket interface, available for dry contact manual switch.
Direction changing is available under both manual and remote.
2. Parameters
3. Installation and wiring
⚠ The working mode for external manual switch is no power dry contact mode, the function of this two interface is the same.
Please follow the electricity standard and below rules:
– To avoid the receiving error, please do not make receiver to connect metal things
– Keep >1.5m distance between receiver and the ground
– Keep >0.3m distance between receiver mad the ceiling
– Keep >0.3m distance between receiver and the transmitter
– For security, please cut off the power before wiring
– To keep components quality, please avoid static. Please use soft cables.
– Please protect cables loader from longitudinal force after installation.
4. Operations
Transmitter pairing
Direction changing
Add new transmitter
Every receiver can programme with at most 20pcs transmitters, the 21st one will cover the 20th automatically
Delete single transmitter
Delete all transmitter
Control mode
There will be 0.5s for motor to change rotation, the longest time rotation is 5 min.
5. Troubles and solutions
Troubles Solutions
Indicator light is on, but no reaction → Please check the wiring and channel choosing
Indicator on transmitter off or dull light → Please check the battery power (battery installation)
Transmitter and receiver work commonly, motor has no rotating → Please check motor wiring